3/8HP Cold Storage Compressor M/HBP NE6187Z R134a For Refrigeration

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xVoltage | 220v 50hz | Horse Power | 3/4HP |
---|---|---|---|
Warranty | 1 Year | After Warranty Service | Online Support |
After-sales Service Provided | Online Support | Showroom Location | None |
Marketing Type | Ordinary Product | Packing | Wooden Case |
Machinery Test Report | Provided | Application | Refrigeration Parts |
Highlight | 3/8HP Cold Storage Compressor,Cold Storage Compressor R134a,Refrigeration Cold Storage Compressor |
Rated Points
Condensing Temperature | Evaporating Temperature | Cooling Capacity | Power Consumption | Gas Flow Rate | Efficiency | ||
50.00°C | 5.00°C | 846 W | 380 W | 21.28 kg/h | 2.23 W/W |
Test Condition: EN12900LBP, Fan/NotControled/220, Return Gas 20°C, Evaporation -35.00°C, Condensing 40.00°C, Ambient 35°C , Liquid 40°C, Subcooling 0K. Data are an indication of performance based simulation.
Performance Curve Data
Condensing Temperature 35°C
Evaporating Temperature °C |
Cooling Capacity W |
Power W | Gas Flow Rate kg/h |
Efficiency W/W |
-15 | 436 | 238 | 9.23 | 1.83 |
-10 | 551 | 257 | 11.72 | 2.14 |
-5 | 688 | 278 | 14.70 | 2.48 |
0 | 850 | 299 | 18.27 | 2.84 |
5 | 1040 | 321 | 22.54 | 3.24 |
10 | 1263 | 345 | 27.61 | 3.66 |
Test Condition: EN12900LBP, Fan/NotControled/220, Return Gas 20°C, Ambient 35°C , Subcooling 0K. Data are an indication of performance based simulation.
Condensing Temperature 45°C
Evaporating Temperature °C |
Cooling Capacity W |
Power W | Gas Flow Rate kg/h |
Efficiency W/W |
-15 | 374 | 249 | 8.67 | 1.5 |
-10 | 477 | 276 | 11.11 | 1.72 |
-5 | 599 | 304 | 14.04 | 1.97 |
0 | 744 | 331 | 17.56 | 2.25 |
5 | 915 | 359 | 21.78 | 2.55 |
10 | 1115 | 388 | 26.80 | 2.87 |
Test Condition: EN12900LBP, Fan/NotControled/220, Return Gas 20°C, Ambient 35°C , Subcooling 0K. Data are an indication of performance based simulation.
Condensing Temperature 55°C
Evaporating Temperature °C |
Cooling Capacity W |
Power W | Gas Flow Rate kg/h |
Efficiency W/W |
-10 | 401 | 292 | 10.40 | 1.37 |
-5 | 508 | 326 | 13.26 | 1.56 |
0 | 636 | 358 | 16.72 | 1.77 |
5 | 786 | 391 | 20.87 | 2.01 |
10 | 963 | 424 | 25.83 | 2.27 |
Test Condition: EN12900LBP, Fan/NotControled/220, Return Gas 20°C, Ambient 35°C , Subcooling 0K. Data are an indication of performance based simulation.
External Dimensions