xAPPROVED REFRIGERANT | R-404A | COOLING CAPACITY | 942 W (LBP) |
---|---|---|---|
EFFICIENCY | 1.26 W/W (LBP) | POWER SUPPLY | 220-240 V 50 Hz |
MOTOR TYPE | CSIR | STANDARD CONDITIONS | ASHRAE |
STARTING TORQUE | HST | Horse Power | 1HP |
APPLICATION | LBP | Packing | Carton Box |
MOQ | 1pcs | Local Service Location | None |
Video Outgoing-inspection | Not Available | Marketing Type | Ordinary Product |
Application | Refrigeration Parts | After-sales Service Provided | Online Support |
Model Number | NT2180GK | Compressor Type | Hermetic Compressor |
Original | Brazil | Keyword | Compressor |
Highlight | R404A Cold Storage Compressor,Small Cold Storage Compressor,220v Refrigeration Compressor |
Rated Points | ||||||
Condensing Temperature |
Evaporating Temperature |
Cooling Capacity |
Power Consumption |
Current | Gas Flow Rate |
Efficiency |
54.40°C | -23.30°C | 942 W | 745 W | 4.65 A | 21.79 kg/h | 1.26 W/W |
Test Condition: ASHRAELBP32, Fan/NotControled/220, Return Gas 32.2°C, Evaporation -23.30°C, Condensing 54.40°C, Ambient 32.2°C , Liquid 32.2°C, Subcooling 22.2K. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and uncertainty guidance.
Condensing Temperature 35°C | |||||
Evaporating Temperature °C |
Cooling Capacity W |
Power W | Current A | Gas Flow Rate kg/h |
Efficiency W/W |
-40 | 424 | 438 | 3.71 | 9.72 | 0.97 |
-35 | 589 | 510 | 3.91 | 13.56 | 1.16 |
-30 | 783 | 579 | 4.12 | 18.08 | 1.35 |
-25 | 1004 | 648 | 4.35 | 23.27 | 1.55 |
-20 | 1250 | 716 | 4.59 | 29.13 | 1.74 |
-15 | 1521 | 786 | 4.85 | 35.66 | 1.93 |
-10 | 1815 | 858 | 5.13 | 42.85 | 2.11 |
Test Condition: ASHRAELBP32, Fan/NotControled/220, Return Gas 32.2°C, Evaporation -23.30°C, Condensing 54.40°C, Ambient 32.2°C , Liquid 32.2°C, Subcooling 22.2K. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and uncertainty guidance.
Condensing Temperature 45°C | |||||
Evaporating Temperature °C |
Cooling Capacity W |
Power W | Current A | Gas Flow Rate kg/h |
Efficiency W/W |
-35 | 525 | 517 | 3.92 | 12.07 | 1.oz |
-30 | 713 | 600 | 4.16 | 16.42 | 1.19 |
-25 | 930 | 685 | 4.44 | 21.53 | 1.36 |
-20 | 1177 | 773 | 4.75 | 27.37 | 1.52 |
-15 | 1452 | 864 | 5.09 | 33.97 | 1.6B |
-10 | 1753 | 96o | 5.46 | 41.3 | 1.83 |
Test Condition: ASHRAELBP32, Fan/NotControled/220, Return Gas 32.2°C, Evaporation -23.30°C, Condensing 54.40°C, Ambient 32.2°C , Liquid 32.2°C, Subcooling 22.2K. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and uncertainty guidance.
Condensing Temperature 55°C | |||||
Evaporating Temperature °C |
Cooling Capacity W |
Power W | Current A | Gas Flow Rate kg/h |
Efficiency W/W |
-30 | 651 | 613 | 4.21 | 14.97 | 1.06 |
-25 | 862 | 711 | 4.54 | 19.9o | 1.21 |
-20 | 1105 | 814 | 4.91 | 25.64 | 1.36 |
-15 | 1379 | 923 | 5.33 | 32.21 | 1.49 |
-10 | 1684 | 1040 | 5.8 | 39.59 | 1.62 |
Test Condition: ASHRAELBP32, Fan/NotControled/220, Return Gas 32.2°C, Evaporation -23.30°C, Condensing 54.40°C, Ambient 32.2°C , Liquid 32.2°C, Subcooling 22.2K. Data in accordance to EN 12900:2013 and AHRI 540:2015 polynomial equation and uncertainty guidance.
External Dimensions