NT2192GK LBP R404 Refrigeration Compressor 1HP High Performance
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xVoltage | 220v 50hz | Horse Power | 1HP |
---|---|---|---|
Warranty | 1 Year | After Warranty Service | Online Support |
After-sales Service Provided | Online Support | ||
High Light | R404 LBP Refrigeration Compressor,NT2192GK LBP Refrigeration Compressor,Refrigeration Compressor 1HP |
Rated Points
Condensing Temperature | Evaporating Temperature | Cooling Capacity | Power Consumption | Gas Flow Rate | Efficiency | ||
40.00°C | -35.00°C | 577 W | 527 W | 15.44 kg/h | 1.09 W/W |
Test Condition: EN12900LBP, Fan/NotControled/220, Return Gas 20°C, Evaporation -35.00°C, Condensing 40.00°C, Ambient 35°C , Liquid 40°C, Subcooling 0K. Data are an indication of performance based simulation.
Performance Curve Data
Condensing Temperature 35°C
Evaporating Temperature °C |
Cooling Capacity W |
Power W | Gas Flow Rate kg/h |
Efficiency W/W |
-40 | 459 | 448 | 11.66 | 1.02 |
-35 | 615 | 525 | 15.71 | 1.17 |
-30 | 816 | 602 | 20.91 | 1.36 |
-25 | 1059 | 679 | 27.29 | 1.56 |
-20 | 1346 | 756 | 34.90 | 1.78 |
-15 | 1675 | 835 | 43.77 | 2.01 |
-10 | 2046 | 914 | 53.93 | 2.24 |
Test Condition: EN12900LBP, Fan/NotControled/220, Return Gas 20°C, Ambient 35°C , Subcooling 0K. Data are an indication of performance based simulation.
Condensing Temperature 45°C
Evaporating Temperature °C |
Cooling Capacity W |
Power W | Gas Flow Rate kg/h |
Efficiency W/W |
-35 | 498 | 538 | 14.42 | 0.93 |
-30 | 665 | 633 | 19.35 | 1.05 |
-25 | 869 | 728 | 25.42 | 1.19 |
-20 | 1109 | 825 | 32.67 | 1.34 |
-15 | 1384 | 923 | 41.14 | 1.5 |
-10 | 1694 | 1022 | 50.87 | 1.66 |
Test Condition: EN12900LBP, Fan/NotControled/220, Return Gas 20°C, Ambient 35°C , Subcooling 0K. Data are an indication of performance based simulation.
Condensing Temperature 55°C
Evaporating Temperature °C |
Cooling Capacity W |
Power W | Gas Flow Rate kg/h |
Efficiency W/W |
-30 | 506 | 661 | 17.27 | 0.77 |
-25 | 669 | 772 | 23.00 | 0.87 |
-20 | 861 | 884 | 29.86 | 0.97 |
-15 | 1082 | 998 | 37.90 | 1.08 |
-10 | 1331 | 1114 | 47.15 | 1.19 |
Test Condition: EN12900LBP, Fan/NotControled/220, Return Gas 20°C, Ambient 35°C , Subcooling 0K. Data are an indication of performance based simulation.
External Dimensions