R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xRefrigerant | R134A | Power Supply | 220V380V460V575V-3PH/50HZ/60HZ |
---|---|---|---|
Nominal HP | Describe | Quality Assurance | A Year |
High Light | Power Supply Cold Storage Compressor,575V Cold Storage Compressor,R134A Cold Storage Compressor |
06DR109 R134a Refrigerant
Physical Data | |||||||||||||||||||||
Model | Nominal HP | Displ. CFM | No. of Cylinders | Suction Line Size (in) | Discharge Line Size (in) | Shipping Weight (lbs) | Oil Charge (pints) | ||||||||||||||
06DR109 | 3 | 8.7 | 2 | 7/8 | 5/8 | 190 | 3 |
Available Voltages | ||||||||
208/230-3-60 | ||||||||
460-3-60 | ||||||||
575-3-60 |
Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz | |||||||||||||||||||||||||||
Saturated Condensing Temperature (F) | Saturated Suction Temperature (F) | ||||||||||||||||||||||||||
-10 | -5 | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | ||||||||||||||
90 | Capacity (Btu/hr) | 8181 | 9636 | 11274 | 13115 | 15176 | 17477 | 20036 | 22872 | 26004 | 29451 | 33231 | 37363 | 41866 | 46759 | ||||||||||||
Power (kW) | 1.18 | 1.26 | 1.34 | 1.42 | 1.49 | 1.56 | 1.62 | 1.68 | 1.73 | 1.77 | 1.8 | 1.83 | 1.84 | 1.84 | |||||||||||||
EER (BTU/WATT-HR) | 6.95 | 7.64 | 8.41 | 9.25 | 10.18 | 11.21 | 12.35 | 13.62 | 15.05 | 16.64 | 18.43 | 20.45 | 22.74 | 25.35 | |||||||||||||
Current (AMPS) | 2.37 | 2.46 | 2.55 | 2.63 | 2.71 | 2.78 | 2.85 | 2.9 | 2.95 | 2.99 | 3.02 | 3.04 | 3.04 | 3.04 | |||||||||||||
110 | Capacity (Btu/hr) | 6422 | 7713 | 9152 | 10757 | 12546 | 14539 | 16753 | 19209 | 21924 | 24917 | 28207 | 31813 | 35754 | 40048 | ||||||||||||
Power (kW) | 1.2 | 1.31 | 1.41 | 1.52 | 1.62 | 1.72 | 1.82 | 1.91 | 2 | 2.08 | 2.15 | 2.22 | 2.28 | 2.33 | |||||||||||||
EER (BTU/WATT-HR) | 5.36 | 5.91 | 6.48 | 7.09 | 7.74 | 8.44 | 9.21 | 10.05 | 10.98 | 11.99 | 13.1 | 14.33 | 15.69 | 17.19 | |||||||||||||
Current (AMPS) | 2.45 | 2.54 | 2.64 | 2.74 | 2.84 | 2.94 | 3.04 | 3.14 | 3.24 | 3.34 | 3.43 | 3.52 | 3.6 | 3.68 | |||||||||||||
130 | Capacity (Btu/hr) | 4785 | 5920 | 7166 | 8542 | 10066 | 11757 | 13633 | 15714 | 18018 | 20565 | 23372 | 26458 | 29843 | 33545 | ||||||||||||
Power (kW) | 1.17 | 1.3 | 1.43 | 1.56 | 1.7 | 1.83 | 1.96 | 2.09 | 2.21 | 2.33 | 2.45 | 2.56 | 2.66 | 2.76 | |||||||||||||
EER (BTU/WATT-HR) | 4.1 | 4.56 | 5.01 | 5.46 | 5.93 | 6.43 | 6.96 | 7.53 | 8.15 | 8.83 | 9.56 | 10.36 | 11.23 | 12.18 | |||||||||||||
Current (AMPS) | 2.44 | 2.54 | 2.66 | 2.78 | 2.91 | 3.05 | 3.2 | 3.35 | 3.51 | 3.67 | 3.83 | 4 | 4.17 | 4.34 |
06DR013 R134a Refrigerant
Physical Data | ||||||||||||||||||||||||
Model | Nominal HP | Displ. CFM | No. of Cylinders | Suction Line Size (in) | Discharge Line Size (in) | Shipping Weight (lbs) | Oil Charge (pints) | |||||||||||||||||
06DR013 | 3 | 13 | 4 | 1 1/8 | 5/8 | 230 | 4 1/2 |
Available Voltages | ||||||||
208/230-3-60 | ||||||||
460-3-60 | ||||||||
575-3-60 |
Tabular Data Summary -Fixed RGT=65°F Subcooling =0°F Voltage: 460-3-60Hz | |||||||||||||||
Saturated condensing | Saturated Suction Temperature (F) | ||||||||||||||
Temperature(F) | -10 | -5 | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | |
90 | Capacity (Btu/hr) | 10510 | 12661 | 15084 | 17804 | 20849 | 24246 | 28021 | 32200 | 36812 | 41882 | 47438 | 53506 | 60113 | 67287 |
Power (kW) | 1.52 | 1.65 | 1.78 | 1.9 | 2.01 | 2.11 | 2.21 | 2.29 | 2.36 | 2.41 | 2.45 | 2.48 | 2.48 | 2.47 | |
EER (BTU/WATT-HR) | 6.9 | 7.67 | 8.49 | 9.39 | 10.38 | 11.48 | 12.71 | 14.08 | 15.61 | 17.35 | 19.33 | 21.6 | 24.22 | 27.27 | |
current (AMPS) | 2.95 | 3.15 | 3.33 | 3.48 | 3.61 | 3.72 | 3.81 | 3.88 | 3.94 | 3.99 | 4.03 | 4.07 | 4.09 | 4.12 | |
110 | capacity (Btu/hr) | 7559 | 9465 | 11590 | 13962 | 16606 | 19551 | 22823 | 26449 | 30455 | 34868 | 39715 | 45023 | 50820 | 57130 |
Power (kW) | 1.5 | 1.68 | 1.86 | 2.03 | 2.19 | 2.35 | 2.5 | 2.64 | 2.77 | 2.88 | 2.99 | 3.07 | 3.14 | 3.19 | |
EER (BTU/WATT-HR) | 5.03 | 5.63 | 6.24 | 6.89 | 7.57 | 8.32 | 9.13 | 10.02 | 11 | 12.09 | 13.3 | 14.66 | 16.18 | 17.9 | |
Current (AMPS) | 2.89 | 3.16 | 3.4 | 3.61 | 3.8 | 3.96 | 4.09 | 4.21 | 4.31 | 4.39 | 4.45 | 4.5 | 4.54 | 4.58 | |
130 | capacity (Btuhr) | 4832 | 6495 | 8327 | 10353 | 12602 | 15099 | 17871 | 20946 | 24350 | 28110 | 32252 | 36804 | 41793 | 47245 |
Power (kW) | 1.32 | 1.56 | 1.79 | 2.03 | 2.25 | 2.47 | 2.69 | 2.9 | 3.09 | 3.28 | 3.45 | 3.61 | 3.75 | 3.88 | |
EER (BTU/WATT-HR) | 3.65 | 4.17 | 4.64 | 5.11 | 5.59 | 6.1 | 6.64 | 7.23 | 7.87 | 8.58 | 9.35 | 10.2 | 11.14 | 12.18 | |
Current (AMPS) | 2.67 | 3.02 | 3.33 | 3.6 | 3.84 | 4.08 | 4.24 | 4.4 | 4.54 | 4.65 | 4.74 | 4.82 | 4.88 | 4.92 |
06DR316 R134a Refrigerant
Physical Data | ||||||||||||||||||||||||
Model | Nominal HP | Displ. CFM | No. of Cylinders | Suction Line Size (in) | Discharge Line Size (in) | Shipping Weight (lbs) | Oil Charge (pints) | |||||||||||||||||
06DR316 | 5 | 15.9 | 4 | 1 1/8 | 5/8 | 235 | 4 1/2 |
Available Voltages | ||||||||
208/230-3-60 | ||||||||
460-3-60 | ||||||||
575-3-60 |
Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz | ||||||||||||||||||||||||||||||
Saturated Condensing Temperature (F) | Saturated Suction Temperature (F) | |||||||||||||||||||||||||||||
-10 | -5 | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | |||||||||||||||||
90 | Capacity (Btu/hr) | 15434 | 18016 | 20924 | 24195 | 27861 | 31959 | 36523 | 41587 | 47186 | 53354 | 60127 | 67538 | 75623 | 84416 | |||||||||||||||
Power (kW) | 2.14 | 2.27 | 2.41 | 2.54 | 2.66 | 2.78 | 2.89 | 3 | 3.09 | 3.17 | 3.24 | 3.29 | 3.33 | 3.35 | ||||||||||||||||
EER (BTU/WATT-HR) | 7.22 | 7.92 | 8.68 | 9.53 | 10.46 | 11.48 | 12.62 | 13.88 | 15.28 | 16.84 | 18.57 | 20.52 | 22.7 | 25.16 | ||||||||||||||||
Current (AMPS) | 4.32 | 4.46 | 4.59 | 4.71 | 4.83 | 4.94 | 5.04 | 5.13 | 5.21 | 5.27 | 5.33 | 5.38 | 5.41 | 5.43 | ||||||||||||||||
110 | Capacity (Btu/hr) | 12521 | 14816 | 17370 | 20218 | 23395 | 26935 | 30872 | 35243 | 40080 | 45420 | 51296 | 57742 | 64795 | 72488 | |||||||||||||||
Power (kW) | 2.34 | 2.52 | 2.69 | 2.87 | 3.04 | 3.21 | 3.37 | 3.53 | 3.68 | 3.82 | 3.95 | 4.06 | 4.17 | 4.26 | ||||||||||||||||
EER (BTU/WATT-HR) | 5.36 | 5.89 | 6.45 | 7.05 | 7.69 | 8.39 | 9.15 | 9.98 | 10.9 | 11.9 | 13 | 14.21 | 15.54 | 17.02 | ||||||||||||||||
Current (AMPS) | 4.62 | 4.74 | 4.87 | 5.01 | 5.16 | 5.31 | 5.47 | 5.64 | 5.81 | 5.98 | 6.16 | 6.34 | 6.52 | 6.7 | ||||||||||||||||
130 | Capacity (Btu/hr) | 9814 | 11841 | 14060 | 16505 | 19210 | 22212 | 25543 | 29240 | 33335 | 37865 | 42863 | 48365 | 54404 | 61016 | |||||||||||||||
Power (kW) | 2.47 | 2.69 | 2.92 | 3.14 | 3.36 | 3.59 | 3.8 | 4.02 | 4.23 | 4.43 | 4.62 | 4.8 | 4.98 | 5.14 | ||||||||||||||||
EER (BTU/WATT-HR) | 3.97 | 4.4 | 4.82 | 5.26 | 5.71 | 6.19 | 6.72 | 7.28 | 7.89 | 8.55 | 9.28 | 10.07 | 10.93 | 11.88 | ||||||||||||||||
Current (AMPS) | 4.73 | 4.88 | 5.05 | 5.25 | 5.47 | 5.71 | 5.97 | 6.25 | 6.55 | 6.87 | 7.21 | 7.57 | 7.94 | 8.33 |
06DR718 R134a Refrigerant
Physical Data | ||||||||||||||||||||||
Model | Nominal HP | Displ. CFM | No. of Cylinders | Suction Line Size (in) | Discharge Line Size (in) | Shipping Weight (lbs) | Oil Charge (pints) | |||||||||||||||
06DR718 | 5 | 18.3 | 4 | 1 3/8 | 7/8 | 250 | 5 1/2 |
Available Voltages | |||||||
208/230-3-60 | |||||||
460-3-60 | |||||||
575-3-60 |
Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz | ||||||||||||||||||||||||||||
Saturated Condensing Temperature (F) | Saturated Suction Temperature (F) | |||||||||||||||||||||||||||
-10 | -5 | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | |||||||||||||||
90 | Capacity (Btu/hr) | 18427 | 21436 | 24843 | 28692 | 33026 | 37886 | 43317 | 49362 | 56062 | 63462 | 71604 | 80530 | 90285 | 100911 | |||||||||||||
Power (kW) | 2.36 | 2.53 | 2.69 | 2.86 | 3.01 | 3.15 | 3.28 | 3.39 | 3.48 | 3.55 | 3.6 | 3.63 | 3.63 | 3.6 | ||||||||||||||
EER (BTU/WATT-HR) | 7.82 | 8.48 | 9.22 | 10.05 | 10.98 | 12.03 | 13.23 | 14.58 | 16.11 | 17.86 | 19.87 | 22.19 | 24.88 | 28.05 | ||||||||||||||
Current (AMPS) | 4.53 | 4.74 | 4.94 | 5.13 | 5.3 | 5.46 | 5.6 | 5.73 | 5.83 | 5.9 | 5.95 | 5.98 | 5.97 | 5.93 | ||||||||||||||
110 | Capacity (Btu/hr) | 15052 | 17715 | 20690 | 24021 | 27750 | 31919 | 36573 | 41754 | 47505 | 53869 | 60889 | 68608 | 77068 | 86313 | |||||||||||||
Power (kW) | 2.51 | 2.73 | 2.95 | 3.17 | 3.38 | 3.59 | 3.79 | 3.98 | 4.15 | 4.31 | 4.45 | 4.57 | 4.66 | 4.74 | ||||||||||||||
EER (BTU/WATT-HR) | 6 | 6.49 | 7.01 | 7.58 | 8.2 | 8.89 | 9.65 | 10.5 | 11.45 | 12.5 | 13.69 | 15.02 | 16.52 | 18.23 | ||||||||||||||
Current (AMPS) | 4.75 | 5 | 5.24 | 5.49 | 5.72 | 5.95 | 6.17 | 6.38 | 6.58 | 6.75 | 6.92 | 7.06 | 7.18 | 7.27 | ||||||||||||||
130 | Capacity (Btu/hr) | 11829 | 14191 | 16779 | 19635 | 22804 | 26328 | 30250 | 34612 | 39458 | 44831 | 50773 | 57329 | 64539 | 72448 | |||||||||||||
Power (kW) | 2.54 | 2.81 | 3.09 | 3.38 | 3.66 | 3.94 | 4.21 | 4.48 | 4.74 | 4.99 | 5.22 | 5.44 | 5.64 | 5.82 | ||||||||||||||
EER (BTU/WATT-HR) | 4.66 | 5.04 | 5.42 | 5.82 | 6.24 | 6.69 | 7.18 | 7.73 | 8.33 | 8.99 | 9.73 | 10.54 | 11.45 | 12.45 | ||||||||||||||
Current (AMPS) | 4.81 | 5.1 | 5.41 | 5.71 | 6.02 | 6.33 | 6.64 | 6.95 | 7.25 | 7.54 | 7.82 | 8.1 | 8.35 | 8.6 |
06DR820 R134a Refrigerant
Physical Data | ||||||||||||||||||||||
Model | Nominal HP | Displ. CFM | No. of Cylinders | Suction Line Size (in) | Discharge Line Size (in) | Shipping Weight (lbs) | Oil Charge (pints) | |||||||||||||||
06DR820 | 6.5 | 20 | 4 | 1 3/8 | 7/8 | 260 | 5 1/2 |
Available Voltages | |||||||
208/230-3-60 | |||||||
460-3-60 | |||||||
575-3-60 |
Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz | ||||||||||||||||||||||||||||
Saturated Condensing Temperature (F) | Saturated Suction Temperature (F) | |||||||||||||||||||||||||||
-10 | -5 | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | |||||||||||||||
90 | Capacity (Btu/hr) | 20361 | 23802 | 27639 | 31909 | 36651 | 41903 | 47701 | 54085 | 61092 | 68761 | 77129 | 86234 | 96115 | 106808 | |||||||||||||
Power (kW) | 2.66 | 2.85 | 3.03 | 3.2 | 3.36 | 3.52 | 3.66 | 3.78 | 3.89 | 3.98 | 4.04 | 4.09 | 4.11 | 4.1 | ||||||||||||||
EER (BTU/WATT-HR) | 7.65 | 8.36 | 9.13 | 9.97 | 10.9 | 11.92 | 13.05 | 14.31 | 15.71 | 17.29 | 19.08 | 21.09 | 23.4 | 26.05 | ||||||||||||||
Current (AMPS) | 5.75 | 5.9 | 6.04 | 6.18 | 6.32 | 6.45 | 6.57 | 6.68 | 6.78 | 6.86 | 6.92 | 6.97 | 6.99 | 6.99 | ||||||||||||||
110 | Capacity (Btu/hr) | 16336 | 19459 | 22906 | 26715 | 30925 | 35572 | 40696 | 46334 | 52523 | 59303 | 66711 | 74784 | 83562 | 93081 | |||||||||||||
Power (kW) | 2.79 | 3.03 | 3.27 | 3.51 | 3.74 | 3.97 | 4.18 | 4.39 | 4.58 | 4.75 | 4.91 | 5.05 | 5.16 | 5.26 | ||||||||||||||
EER (BTU/WATT-HR) | 5.85 | 6.41 | 7 | 7.61 | 8.26 | 8.97 | 9.73 | 10.57 | 11.48 | 12.49 | 13.59 | 14.82 | 16.19 | 17.71 | ||||||||||||||
Current (AMPS) | 6.01 | 6.14 | 6.29 | 6.46 | 6.63 | 6.82 | 7.02 | 7.23 | 7.44 | 7.65 | 7.87 | 8.08 | 8.3 | 8.5 | ||||||||||||||
130 | Capacity (Btu/hr) | 12471 | 15262 | 18305 | 21640 | 25303 | 29333 | 33767 | 38645 | 44003 | 49880 | 56313 | 63341 | 71002 | 79333 | |||||||||||||
Power (kW) | 2.79 | 3.1 | 3.4 | 3.71 | 4.01 | 4.31 | 4.6 | 4.89 | 5.16 | 5.42 | 5.67 | 5.91 | 6.13 | 6.32 | ||||||||||||||
EER (BTU/WATT-HR) | 4.46 | 4.93 | 5.38 | 5.84 | 6.31 | 6.81 | 7.34 | 7.91 | 8.53 | 9.2 | 9.92 | 10.72 | 11.59 | 12.55 | ||||||||||||||
Current (AMPS) | 6.01 | 6.18 | 6.38 | 6.61 | 6.88 | 7.17 | 7.5 | 7.84 | 8.22 | 8.61 | 9.02 | 9.46 | 9.9 | 10.36 |
06DR725 R134a Refrigerant
Physical Data | ||||||||||||||||||||||
Model | Nominal HP | Displ. CFM | No. of Cylinders | Suction Line Size (in) | Discharge Line Size (in) | Shipping Weight (lbs) | Oil Charge (pints) | |||||||||||||||
06DR725 | 6.5 | 23.9 | 6 | 1 3/8 | 7/8 | 310 | 8 |
Available Voltages | |||||||
208/230-3-60 | |||||||
460-3-60 | |||||||
575-3-60 |
Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz | ||||||||||||||||||||||||||||
Saturated Condensing Temperature (F) | Saturated Suction Temperature (F) | |||||||||||||||||||||||||||
-10 | -5 | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | |||||||||||||||
90 | Capacity (Btu/hr) | 21906 | 26197 | 31017 | 36417 | 42451 | 49171 | 56630 | 64880 | 73974 | 83964 | 94904 | 106845 | 119840 | 133943 | |||||||||||||
Power (kW) | 2.78 | 3.03 | 3.29 | 3.54 | 3.78 | 4.02 | 4.25 | 4.47 | 4.69 | 4.89 | 5.08 | 5.26 | 5.42 | 5.57 | ||||||||||||||
EER (BTU/WATT-HR) | 7.88 | 8.63 | 9.43 | 10.29 | 11.22 | 12.23 | 13.32 | 14.5 | 15.78 | 17.17 | 18.68 | 20.32 | 22.1 | 24.03 | ||||||||||||||
Current (AMPS) | 5.89 | 6.2 | 6.48 | 6.74 | 6.97 | 7.17 | 7.36 | 7.53 | 7.68 | 7.82 | 7.94 | 8.05 | 8.15 | 8.25 | ||||||||||||||
110 | Capacity (Btu/hr) | 16219 | 20042 | 24293 | 29024 | 34289 | 40140 | 46629 | 53809 | 61733 | 70453 | 80022 | 90493 | 101917 | 114348 | |||||||||||||
Power (kW) | 2.81 | 3.14 | 3.48 | 3.81 | 4.13 | 4.46 | 4.77 | 5.08 | 5.38 | 5.67 | 5.95 | 6.22 | 6.48 | 6.72 | ||||||||||||||
EER (BTU/WATT-HR) | 5.77 | 6.37 | 6.99 | 7.62 | 8.29 | 9.01 | 9.77 | 10.59 | 11.47 | 12.42 | 13.44 | 14.54 | 15.73 | 17.01 | ||||||||||||||
Current (AMPS) | 5.95 | 6.33 | 6.67 | 6.99 | 7.27 | 7.52 | 7.75 | 7.96 | 8.14 | 8.31 | 8.45 | 8.58 | 8.7 | 8.8 | ||||||||||||||
130 | Capacity (Btu/hr) | 10907 | 14266 | 17953 | 22021 | 26521 | 31507 | 37032 | 43147 | 49906 | 57360 | 65564 | 74568 | 84426 | 95191 | |||||||||||||
Power (kW) | 2.63 | 3.05 | 3.48 | 3.9 | 4.32 | 4.73 | 5.14 | 5.55 | 5.95 | 6.34 | 6.72 | 7.09 | 7.45 | 7.8 | ||||||||||||||
EER (BTU/WATT-HR) | 4.15 | 4.67 | 5.16 | 5.65 | 6.14 | 6.66 | 7.2 | 7.78 | 8.39 | 9.05 | 9.76 | 10.52 | 11.33 | 12.21 | ||||||||||||||
Current (AMPS) | 5.83 | 6.28 | 6.69 | 7.06 | 7.4 | 7.71 | 7.99 | 8.23 | 8.45 | 8.65 | 8.82 | 8.97 | 9.11 | 9.22 |
06DR228 R134a Refrigerant
Physical Data | ||||||||||||||||||||||
Model | Nominal HP | Displ. CFM | No. of Cylinders | Suction Line Size (in) | Discharge Line Size (in) | Shipping Weight (lbs) | Oil Charge (pints) | |||||||||||||||
06DR228 | 7.5 | 28 | 6 | 1 5/8 | 7/8 | 315 | 8 |
Available Voltages | |||||||
208/230-3-60 | |||||||
460-3-60 | |||||||
575-3-60 |
Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz | ||||||||||||||||||||||||||||
Saturated Condensing Temperature (F) | Saturated Suction Temperature (F) | |||||||||||||||||||||||||||
-10 | -5 | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | |||||||||||||||
90 | Capacity (Btu/hr) | 28277 | 33009 | 38248 | 44043 | 50442 | 57493 | 65244 | 73744 | 83040 | 93182 | 104216 | 116192 | 129158 | 143162 | |||||||||||||
Power (kW) | 3.7 | 3.96 | 4.22 | 4.46 | 4.68 | 4.89 | 5.08 | 5.26 | 5.41 | 5.53 | 5.64 | 5.71 | 5.76 | 5.77 | ||||||||||||||
EER (BTU/WATT-HR) | 7.64 | 8.33 | 9.07 | 9.88 | 10.77 | 11.75 | 12.83 | 14.03 | 15.36 | 16.84 | 18.49 | 20.35 | 22.44 | 24.81 | ||||||||||||||
Current (AMPS) | 8.68 | 8.99 | 9.27 | 9.52 | 9.74 | 9.95 | 10.12 | 10.28 | 10.41 | 10.52 | 10.61 | 10.68 | 10.73 | 10.76 | ||||||||||||||
110 | Capacity (Btu/hr) | 22692 | 27058 | 31842 | 37092 | 42857 | 49184 | 56121 | 63718 | 72022 | 81081 | 90944 | 101659 | 113274 | 125838 | |||||||||||||
Power (kW) | 3.88 | 4.24 | 4.59 | 4.93 | 5.26 | 5.57 | 5.87 | 6.15 | 6.41 | 6.65 | 6.87 | 7.06 | 7.23 | 7.37 | ||||||||||||||
EER (BTU/WATT-HR) | 5.85 | 6.38 | 6.94 | 7.53 | 8.15 | 8.83 | 9.56 | 10.36 | 11.23 | 12.19 | 13.24 | 14.39 | 15.67 | 17.08 | ||||||||||||||
Current (AMPS) | 8.91 | 9.29 | 9.65 | 9.98 | 10.29 | 10.57 | 10.83 | 11.06 | 11.27 | 11.47 | 11.64 | 11.79 | 11.92 | 12.03 | ||||||||||||||
130 | Capacity (Btu/hr) | 17123 | 21092 | 25389 | 30063 | 35162 | 40733 | 46826 | 53488 | 60768 | 68714 | 77374 | 86797 | 97029 | 108121 | |||||||||||||
Power (kW) | 3.83 | 4.3 | 4.76 | 5.21 | 5.65 | 6.08 | 6.5 | 6.91 | 7.29 | 7.66 | 8.01 | 8.33 | 8.63 | 8.91 | ||||||||||||||
EER (BTU/WATT-HR) | 4.47 | 4.91 | 5.34 | 5.77 | 6.22 | 6.69 | 7.2 | 7.75 | 8.33 | 8.97 | 9.66 | 10.42 | 11.24 | 12.13 | ||||||||||||||
Current (AMPS) | 8.89 | 9.36 | 9.81 | 10.23 | 10.63 | 11 | 11.35 | 11.67 | 11.98 | 12.26 | 12.53 | 12.77 | 12.99 | 13.2 |
06DR337 R134a Refrigerant
Physical Data | ||||||||||||||||||||||||||||
Model | Nominal HP | Displ. CFM | No. of Cylinders | Suction Line Size (in) | Discharge Line Size (in) | Shipping Weight (lbs) | Oil Charge (pints) | |||||||||||||||||||||
06DR337 | 10 | 37.1 | 6 | 1 5/8 | 1 1/8 | 325 | 8 |
Available Voltages | |||||||
208/230-3-60 | |||||||
460-3-60 | |||||||
575-3-60 |
Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz | |||||||||||||||||||||||||||||||||||
Saturated Condensing Temperature (F) | Saturated Suction Temperature (F) | ||||||||||||||||||||||||||||||||||
-10 | -5 | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | ||||||||||||||||||||||
90 | Capacity (Btu/hr) | 39462 | 45776 | 52701 | 60302 | 68638 | 77773 | 87768 | 98686 | 110587 | 123534 | 137590 | 152815 | 169271 | 187022 | ||||||||||||||||||||
Power (kW) | 5.11 | 5.44 | 5.76 | 6.06 | 6.34 | 6.61 | 6.86 | 7.09 | 7.3 | 7.5 | 7.68 | 7.85 | 7.99 | 8.12 | |||||||||||||||||||||
EER (BTU/WATT-HR) | 7.72 | 8.41 | 9.16 | 9.96 | 10.83 | 11.77 | 12.8 | 13.92 | 15.14 | 16.47 | 17.91 | 19.48 | 21.19 | 23.04 | |||||||||||||||||||||
Current (AMPS) | 8.78 | 9.33 | 9.81 | 10.24 | 10.61 | 10.94 | 11.22 | 11.47 | 11.69 | 11.88 | 12.06 | 12.22 | 12.37 | 12.52 | |||||||||||||||||||||
110 | Capacity (Btu/hr) | 32180 | 38160 | 44636 | 51669 | 59323 | 67659 | 76738 | 86623 | 97375 | 109058 | 121731 | 135458 | 150300 | 166320 | ||||||||||||||||||||
Power (kW) | 5.45 | 5.91 | 6.35 | 6.77 | 7.17 | 7.56 | 7.93 | 8.28 | 8.61 | 8.93 | 9.22 | 9.5 | 9.75 | 9.99 | |||||||||||||||||||||
EER (BTU/WATT-HR) | 5.9 | 6.46 | 7.03 | 7.63 | 8.27 | 8.95 | 9.68 | 10.46 | 11.31 | 12.22 | 13.2 | 14.26 | 15.41 | 16.64 | |||||||||||||||||||||
Current (AMPS) | 9.25 | 9.94 | 10.56 | 11.1 | 11.57 | 11.98 | 12.33 | 12.63 | 12.88 | 13.08 | 13.26 | 13.4 | 13.51 | 13.61 | |||||||||||||||||||||
130 | Capacity (Btu/hr) | 24516 | 30125 | 36113 | 42542 | 49476 | 56974 | 65100 | 73915 | 83481 | 93860 | 105114 | 117305 | 130495 | 144746 | ||||||||||||||||||||
Power (kW) | 5.53 | 6.13 | 6.71 | 7.28 | 7.82 | 8.35 | 8.86 | 9.35 | 9.82 | 10.27 | 10.71 | 11.12 | 11.51 | 11.88 | |||||||||||||||||||||
EER (BTU/WATT-HR) | 4.43 | 4.91 | 5.38 | 5.85 | 6.32 | 6.82 | 7.35 | 7.9 | 8.5 | 9.14 | 9.82 | 10.55 | 11.34 | 12.18 | |||||||||||||||||||||
Current (AMPS) | 9.48 | 10.3 | 11.02 | 11.65 | 12.19 | 12.66 | 13.04 | 13.36 | 13.62 | 13.81 | 13.96 | 14.05 | 14.1 | 14.12 |
06DR541 R404A/R507 Refrigerants
Physical Data | ||||||||||||||||||||||||||||
Model | Nominal HP | Displ. CFM | No. of Cylinders | Suction Line Size (in) | Discharge Line Size (in) | Shipping Weight (lbs) | Oil Charge (pints) | |||||||||||||||||||||
06DR541 | 15 | 41 | 6 | 1 5/8 | 1 1/8 | 325 | 8 |
Available Voltages | |||||||
208/230-3-60 | |||||||
460-3-60 | |||||||
575-3-60 |
Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz | |||||||||||||||||||||||||||||||||||
Saturated Condensing Temperature (F) | Saturated Suction Temperature (F) | ||||||||||||||||||||||||||||||||||
-10 | -5 | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | ||||||||||||||||||||||
90 | Capacity (Btu/hr) | 43729 | 50724 | 58399 | 66821 | 76059 | 86181 | 97257 | 109354 | 122542 | 136889 | 152464 | 169335 | 187571 | 207240 | ||||||||||||||||||||
Power (kW) | 5.66 | 6.03 | 6.38 | 6.71 | 7.02 | 7.32 | 7.6 | 7.85 | 8.09 | 8.31 | 8.51 | 8.69 | 8.85 | 8.99 | |||||||||||||||||||||
EER (BTU/WATT-HR) | 7.72 | 8.41 | 9.16 | 9.96 | 10.83 | 11.77 | 12.8 | 13.92 | 15.14 | 16.47 | 17.91 | 19.48 | 21.19 | 23.04 | |||||||||||||||||||||
Current (AMPS) | 9.66 | 10.26 | 10.79 | 11.26 | 11.67 | 12.03 | 12.34 | 12.62 | 12.86 | 13.07 | 13.26 | 13.44 | 13.61 | 13.77 | |||||||||||||||||||||
110 | Capacity (Btu/hr) | 35659 | 42285 | 49461 | 57255 | 65736 | 74973 | 85034 | 95988 | 107903 | 120848 | 134891 | 150102 | 166549 | 184300 | ||||||||||||||||||||
Power (kW) | 6.04 | 6.55 | 7.03 | 7.5 | 7.95 | 8.38 | 8.79 | 9.17 | 9.54 | 9.89 | 10.22 | 10.52 | 10.81 | 11.07 | |||||||||||||||||||||
EER (BTU/WATT-HR) | 5.9 | 6.46 | 7.03 | 7.63 | 8.27 | 8.95 | 9.68 | 10.46 | 11.31 | 12.22 | 13.2 | 14.26 | 15.41 | 16.64 | |||||||||||||||||||||
Current (AMPS) | 10.17 | 10.94 | 11.62 | 12.21 | 12.73 | 13.18 | 13.56 | 13.89 | 14.16 | 14.39 | 14.58 | 14.74 | 14.86 | 14.97 | |||||||||||||||||||||
130 | Capacity (Btu/hr) | 27167 | 33382 | 40017 | 47142 | 54824 | 63133 | 72138 | 81906 | 92506 | 104007 | 116478 | 129987 | 144603 | 160394 | ||||||||||||||||||||
Power (kW) | 6.13 | 6.79 | 7.44 | 8.06 | 8.67 | 9.25 | 9.82 | 10.36 | 10.88 | 11.38 | 11.86 | 12.32 | 12.75 | 13.16 | |||||||||||||||||||||
EER (BTU/WATT-HR) | 4.43 | 4.91 | 5.38 | 5.85 | 6.32 | 6.82 | 7.35 | 7.9 | 8.5 | 9.14 | 9.82 | 10.55 | 11.34 | 12.18 | |||||||||||||||||||||
Current (AMPS) | 10.43 | 11.33 | 12.12 | 12.81 | 13.41 | 13.92 | 14.35 | 14.7 | 14.98 | 15.19 | 15.35 | 15.46 | 15.52 | 15.53 |