Refrigerant R134A Power Supply 220V380V460V575V-3PH/50HZ/60HZ
Nominal HP Describe Quality Assurance A Year
High Light

Power Supply Cold Storage Compressor

,

575V Cold Storage Compressor

,

R134A Cold Storage Compressor

Leave a Message
Product Description

 

06DR109     R134a Refrigerant

 

Physical Data
Model Nominal HP Displ. CFM No. of Cylinders Suction Line Size (in) Discharge Line Size (in) Shipping Weight (lbs) Oil Charge (pints)
06DR109 3 8.7 2 7/8 5/8 190 3

 

Available Voltages
208/230-3-60
460-3-60
575-3-60

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 0

 

Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz
Saturated Condensing Temperature (F) Saturated Suction Temperature (F)
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55
90 Capacity (Btu/hr) 8181 9636 11274 13115 15176 17477 20036 22872 26004 29451 33231 37363 41866 46759
Power (kW) 1.18 1.26 1.34 1.42 1.49 1.56 1.62 1.68 1.73 1.77 1.8 1.83 1.84 1.84
EER (BTU/WATT-HR) 6.95 7.64 8.41 9.25 10.18 11.21 12.35 13.62 15.05 16.64 18.43 20.45 22.74 25.35
Current (AMPS) 2.37 2.46 2.55 2.63 2.71 2.78 2.85 2.9 2.95 2.99 3.02 3.04 3.04 3.04
110 Capacity (Btu/hr) 6422 7713 9152 10757 12546 14539 16753 19209 21924 24917 28207 31813 35754 40048
Power (kW) 1.2 1.31 1.41 1.52 1.62 1.72 1.82 1.91 2 2.08 2.15 2.22 2.28 2.33
EER (BTU/WATT-HR) 5.36 5.91 6.48 7.09 7.74 8.44 9.21 10.05 10.98 11.99 13.1 14.33 15.69 17.19
Current (AMPS) 2.45 2.54 2.64 2.74 2.84 2.94 3.04 3.14 3.24 3.34 3.43 3.52 3.6 3.68
130 Capacity (Btu/hr) 4785 5920 7166 8542 10066 11757 13633 15714 18018 20565 23372 26458 29843 33545
Power (kW) 1.17 1.3 1.43 1.56 1.7 1.83 1.96 2.09 2.21 2.33 2.45 2.56 2.66 2.76
EER (BTU/WATT-HR) 4.1 4.56 5.01 5.46 5.93 6.43 6.96 7.53 8.15 8.83 9.56 10.36 11.23 12.18
Current (AMPS) 2.44 2.54 2.66 2.78 2.91 3.05 3.2 3.35 3.51 3.67 3.83 4 4.17 4.34

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 1

 

 

 

06DR013   R134a Refrigerant

 

Physical Data
Model Nominal HP Displ. CFM No. of Cylinders Suction Line Size (in) Discharge Line Size (in) Shipping Weight (lbs) Oil Charge (pints)
06DR013 3 13 4 1 1/8 5/8 230 4 1/2

 

Available Voltages
208/230-3-60
460-3-60
575-3-60

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 2

 

Tabular Data Summary -Fixed RGT=65°F Subcooling =0°F Voltage: 460-3-60Hz
Saturated condensing Saturated Suction Temperature (F)
Temperature(F) -10 -5 0 5 10 15 20 25 30 35 40 45 50 55
90 Capacity (Btu/hr) 10510 12661 15084 17804 20849 24246 28021 32200 36812 41882 47438 53506 60113 67287
Power (kW) 1.52 1.65 1.78 1.9 2.01 2.11 2.21 2.29 2.36 2.41 2.45 2.48 2.48 2.47
EER (BTU/WATT-HR) 6.9 7.67 8.49 9.39 10.38 11.48 12.71 14.08 15.61 17.35 19.33 21.6 24.22 27.27
current (AMPS) 2.95 3.15 3.33 3.48 3.61 3.72 3.81 3.88 3.94 3.99 4.03 4.07 4.09 4.12
110 capacity (Btu/hr) 7559 9465 11590 13962 16606 19551 22823 26449 30455 34868 39715 45023 50820 57130
Power (kW) 1.5 1.68 1.86 2.03 2.19 2.35 2.5 2.64 2.77 2.88 2.99 3.07 3.14 3.19
EER (BTU/WATT-HR) 5.03 5.63 6.24 6.89 7.57 8.32 9.13 10.02 11 12.09 13.3 14.66 16.18 17.9
Current (AMPS) 2.89 3.16 3.4 3.61 3.8 3.96 4.09 4.21 4.31 4.39 4.45 4.5 4.54 4.58
130 capacity (Btuhr) 4832 6495 8327 10353 12602 15099 17871 20946 24350 28110 32252 36804 41793 47245
Power (kW) 1.32 1.56 1.79 2.03 2.25 2.47 2.69 2.9 3.09 3.28 3.45 3.61 3.75 3.88
EER (BTU/WATT-HR) 3.65 4.17 4.64 5.11 5.59 6.1 6.64 7.23 7.87 8.58 9.35 10.2 11.14 12.18
Current (AMPS) 2.67 3.02 3.33 3.6 3.84 4.08 4.24 4.4 4.54 4.65 4.74 4.82 4.88 4.92

 

 

 

06DR316   R134a Refrigerant

Physical Data
Model Nominal HP Displ. CFM No. of Cylinders Suction Line Size (in) Discharge Line Size (in) Shipping Weight (lbs) Oil Charge (pints)
06DR316 5 15.9 4 1 1/8 5/8 235 4 1/2

 

Available Voltages
208/230-3-60
460-3-60
575-3-60

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 3

 

Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz
Saturated Condensing Temperature (F) Saturated Suction Temperature (F)
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55
90 Capacity (Btu/hr) 15434 18016 20924 24195 27861 31959 36523 41587 47186 53354 60127 67538 75623 84416
Power (kW) 2.14 2.27 2.41 2.54 2.66 2.78 2.89 3 3.09 3.17 3.24 3.29 3.33 3.35
EER (BTU/WATT-HR) 7.22 7.92 8.68 9.53 10.46 11.48 12.62 13.88 15.28 16.84 18.57 20.52 22.7 25.16
Current (AMPS) 4.32 4.46 4.59 4.71 4.83 4.94 5.04 5.13 5.21 5.27 5.33 5.38 5.41 5.43
110 Capacity (Btu/hr) 12521 14816 17370 20218 23395 26935 30872 35243 40080 45420 51296 57742 64795 72488
Power (kW) 2.34 2.52 2.69 2.87 3.04 3.21 3.37 3.53 3.68 3.82 3.95 4.06 4.17 4.26
EER (BTU/WATT-HR) 5.36 5.89 6.45 7.05 7.69 8.39 9.15 9.98 10.9 11.9 13 14.21 15.54 17.02
Current (AMPS) 4.62 4.74 4.87 5.01 5.16 5.31 5.47 5.64 5.81 5.98 6.16 6.34 6.52 6.7
130 Capacity (Btu/hr) 9814 11841 14060 16505 19210 22212 25543 29240 33335 37865 42863 48365 54404 61016
Power (kW) 2.47 2.69 2.92 3.14 3.36 3.59 3.8 4.02 4.23 4.43 4.62 4.8 4.98 5.14
EER (BTU/WATT-HR) 3.97 4.4 4.82 5.26 5.71 6.19 6.72 7.28 7.89 8.55 9.28 10.07 10.93 11.88
Current (AMPS) 4.73 4.88 5.05 5.25 5.47 5.71 5.97 6.25 6.55 6.87 7.21 7.57 7.94 8.33

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 4

 

 

 

06DR718   R134a Refrigerant

Physical Data
Model Nominal HP Displ. CFM No. of Cylinders Suction Line Size (in) Discharge Line Size (in) Shipping Weight (lbs) Oil Charge (pints)
06DR718 5 18.3 4 1 3/8 7/8 250 5 1/2

 

Available Voltages
208/230-3-60
460-3-60
575-3-60

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 5

 

Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz
Saturated Condensing Temperature (F) Saturated Suction Temperature (F)
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55
90 Capacity (Btu/hr) 18427 21436 24843 28692 33026 37886 43317 49362 56062 63462 71604 80530 90285 100911
Power (kW) 2.36 2.53 2.69 2.86 3.01 3.15 3.28 3.39 3.48 3.55 3.6 3.63 3.63 3.6
EER (BTU/WATT-HR) 7.82 8.48 9.22 10.05 10.98 12.03 13.23 14.58 16.11 17.86 19.87 22.19 24.88 28.05
Current (AMPS) 4.53 4.74 4.94 5.13 5.3 5.46 5.6 5.73 5.83 5.9 5.95 5.98 5.97 5.93
110 Capacity (Btu/hr) 15052 17715 20690 24021 27750 31919 36573 41754 47505 53869 60889 68608 77068 86313
Power (kW) 2.51 2.73 2.95 3.17 3.38 3.59 3.79 3.98 4.15 4.31 4.45 4.57 4.66 4.74
EER (BTU/WATT-HR) 6 6.49 7.01 7.58 8.2 8.89 9.65 10.5 11.45 12.5 13.69 15.02 16.52 18.23
Current (AMPS) 4.75 5 5.24 5.49 5.72 5.95 6.17 6.38 6.58 6.75 6.92 7.06 7.18 7.27
130 Capacity (Btu/hr) 11829 14191 16779 19635 22804 26328 30250 34612 39458 44831 50773 57329 64539 72448
Power (kW) 2.54 2.81 3.09 3.38 3.66 3.94 4.21 4.48 4.74 4.99 5.22 5.44 5.64 5.82
EER (BTU/WATT-HR) 4.66 5.04 5.42 5.82 6.24 6.69 7.18 7.73 8.33 8.99 9.73 10.54 11.45 12.45
Current (AMPS) 4.81 5.1 5.41 5.71 6.02 6.33 6.64 6.95 7.25 7.54 7.82 8.1 8.35 8.6

 

 

06DR820   R134a Refrigerant

Physical Data
Model Nominal HP Displ. CFM No. of Cylinders Suction Line Size (in) Discharge Line Size (in) Shipping Weight (lbs) Oil Charge (pints)
06DR820 6.5 20 4 1 3/8 7/8 260 5 1/2

 

Available Voltages
208/230-3-60
460-3-60
575-3-60

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 6

 

Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz
Saturated Condensing Temperature (F) Saturated Suction Temperature (F)
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55
90 Capacity (Btu/hr) 20361 23802 27639 31909 36651 41903 47701 54085 61092 68761 77129 86234 96115 106808
Power (kW) 2.66 2.85 3.03 3.2 3.36 3.52 3.66 3.78 3.89 3.98 4.04 4.09 4.11 4.1
EER (BTU/WATT-HR) 7.65 8.36 9.13 9.97 10.9 11.92 13.05 14.31 15.71 17.29 19.08 21.09 23.4 26.05
Current (AMPS) 5.75 5.9 6.04 6.18 6.32 6.45 6.57 6.68 6.78 6.86 6.92 6.97 6.99 6.99
110 Capacity (Btu/hr) 16336 19459 22906 26715 30925 35572 40696 46334 52523 59303 66711 74784 83562 93081
Power (kW) 2.79 3.03 3.27 3.51 3.74 3.97 4.18 4.39 4.58 4.75 4.91 5.05 5.16 5.26
EER (BTU/WATT-HR) 5.85 6.41 7 7.61 8.26 8.97 9.73 10.57 11.48 12.49 13.59 14.82 16.19 17.71
Current (AMPS) 6.01 6.14 6.29 6.46 6.63 6.82 7.02 7.23 7.44 7.65 7.87 8.08 8.3 8.5
130 Capacity (Btu/hr) 12471 15262 18305 21640 25303 29333 33767 38645 44003 49880 56313 63341 71002 79333
Power (kW) 2.79 3.1 3.4 3.71 4.01 4.31 4.6 4.89 5.16 5.42 5.67 5.91 6.13 6.32
EER (BTU/WATT-HR) 4.46 4.93 5.38 5.84 6.31 6.81 7.34 7.91 8.53 9.2 9.92 10.72 11.59 12.55
Current (AMPS) 6.01 6.18 6.38 6.61 6.88 7.17 7.5 7.84 8.22 8.61 9.02 9.46 9.9 10.36

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 7

 

06DR725   R134a Refrigerant

Physical Data
Model Nominal HP Displ. CFM No. of Cylinders Suction Line Size (in) Discharge Line Size (in) Shipping Weight (lbs) Oil Charge (pints)
06DR725 6.5 23.9 6 1 3/8 7/8 310 8

 

Available Voltages
208/230-3-60
460-3-60
575-3-60

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 8

 

Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz
Saturated Condensing Temperature (F) Saturated Suction Temperature (F)
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55
90 Capacity (Btu/hr) 21906 26197 31017 36417 42451 49171 56630 64880 73974 83964 94904 106845 119840 133943
Power (kW) 2.78 3.03 3.29 3.54 3.78 4.02 4.25 4.47 4.69 4.89 5.08 5.26 5.42 5.57
EER (BTU/WATT-HR) 7.88 8.63 9.43 10.29 11.22 12.23 13.32 14.5 15.78 17.17 18.68 20.32 22.1 24.03
Current (AMPS) 5.89 6.2 6.48 6.74 6.97 7.17 7.36 7.53 7.68 7.82 7.94 8.05 8.15 8.25
110 Capacity (Btu/hr) 16219 20042 24293 29024 34289 40140 46629 53809 61733 70453 80022 90493 101917 114348
Power (kW) 2.81 3.14 3.48 3.81 4.13 4.46 4.77 5.08 5.38 5.67 5.95 6.22 6.48 6.72
EER (BTU/WATT-HR) 5.77 6.37 6.99 7.62 8.29 9.01 9.77 10.59 11.47 12.42 13.44 14.54 15.73 17.01
Current (AMPS) 5.95 6.33 6.67 6.99 7.27 7.52 7.75 7.96 8.14 8.31 8.45 8.58 8.7 8.8
130 Capacity (Btu/hr) 10907 14266 17953 22021 26521 31507 37032 43147 49906 57360 65564 74568 84426 95191
Power (kW) 2.63 3.05 3.48 3.9 4.32 4.73 5.14 5.55 5.95 6.34 6.72 7.09 7.45 7.8
EER (BTU/WATT-HR) 4.15 4.67 5.16 5.65 6.14 6.66 7.2 7.78 8.39 9.05 9.76 10.52 11.33 12.21
Current (AMPS) 5.83 6.28 6.69 7.06 7.4 7.71 7.99 8.23 8.45 8.65 8.82 8.97 9.11 9.22

 

06DR228   R134a Refrigerant

Physical Data
Model Nominal HP Displ. CFM No. of Cylinders Suction Line Size (in) Discharge Line Size (in) Shipping Weight (lbs) Oil Charge (pints)
06DR228 7.5 28 6 1 5/8 7/8 315 8

 

Available Voltages
208/230-3-60
460-3-60
575-3-60

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 9

 

Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz
Saturated Condensing Temperature (F) Saturated Suction Temperature (F)
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55
90 Capacity (Btu/hr) 28277 33009 38248 44043 50442 57493 65244 73744 83040 93182 104216 116192 129158 143162
Power (kW) 3.7 3.96 4.22 4.46 4.68 4.89 5.08 5.26 5.41 5.53 5.64 5.71 5.76 5.77
EER (BTU/WATT-HR) 7.64 8.33 9.07 9.88 10.77 11.75 12.83 14.03 15.36 16.84 18.49 20.35 22.44 24.81
Current (AMPS) 8.68 8.99 9.27 9.52 9.74 9.95 10.12 10.28 10.41 10.52 10.61 10.68 10.73 10.76
110 Capacity (Btu/hr) 22692 27058 31842 37092 42857 49184 56121 63718 72022 81081 90944 101659 113274 125838
Power (kW) 3.88 4.24 4.59 4.93 5.26 5.57 5.87 6.15 6.41 6.65 6.87 7.06 7.23 7.37
EER (BTU/WATT-HR) 5.85 6.38 6.94 7.53 8.15 8.83 9.56 10.36 11.23 12.19 13.24 14.39 15.67 17.08
Current (AMPS) 8.91 9.29 9.65 9.98 10.29 10.57 10.83 11.06 11.27 11.47 11.64 11.79 11.92 12.03
130 Capacity (Btu/hr) 17123 21092 25389 30063 35162 40733 46826 53488 60768 68714 77374 86797 97029 108121
Power (kW) 3.83 4.3 4.76 5.21 5.65 6.08 6.5 6.91 7.29 7.66 8.01 8.33 8.63 8.91
EER (BTU/WATT-HR) 4.47 4.91 5.34 5.77 6.22 6.69 7.2 7.75 8.33 8.97 9.66 10.42 11.24 12.13
Current (AMPS) 8.89 9.36 9.81 10.23 10.63 11 11.35 11.67 11.98 12.26 12.53 12.77 12.99 13.2

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 10

 

 

06DR337   R134a Refrigerant

Physical Data
Model Nominal HP Displ. CFM No. of Cylinders Suction Line Size (in) Discharge Line Size (in) Shipping Weight (lbs) Oil Charge (pints)
06DR337 10 37.1 6 1 5/8 1 1/8 325 8

 

Available Voltages
208/230-3-60
460-3-60
575-3-60

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 11

 

Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz
Saturated Condensing Temperature (F) Saturated Suction Temperature (F)
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55
90 Capacity (Btu/hr) 39462 45776 52701 60302 68638 77773 87768 98686 110587 123534 137590 152815 169271 187022
Power (kW) 5.11 5.44 5.76 6.06 6.34 6.61 6.86 7.09 7.3 7.5 7.68 7.85 7.99 8.12
EER (BTU/WATT-HR) 7.72 8.41 9.16 9.96 10.83 11.77 12.8 13.92 15.14 16.47 17.91 19.48 21.19 23.04
Current (AMPS) 8.78 9.33 9.81 10.24 10.61 10.94 11.22 11.47 11.69 11.88 12.06 12.22 12.37 12.52
110 Capacity (Btu/hr) 32180 38160 44636 51669 59323 67659 76738 86623 97375 109058 121731 135458 150300 166320
Power (kW) 5.45 5.91 6.35 6.77 7.17 7.56 7.93 8.28 8.61 8.93 9.22 9.5 9.75 9.99
EER (BTU/WATT-HR) 5.9 6.46 7.03 7.63 8.27 8.95 9.68 10.46 11.31 12.22 13.2 14.26 15.41 16.64
Current (AMPS) 9.25 9.94 10.56 11.1 11.57 11.98 12.33 12.63 12.88 13.08 13.26 13.4 13.51 13.61
130 Capacity (Btu/hr) 24516 30125 36113 42542 49476 56974 65100 73915 83481 93860 105114 117305 130495 144746
Power (kW) 5.53 6.13 6.71 7.28 7.82 8.35 8.86 9.35 9.82 10.27 10.71 11.12 11.51 11.88
EER (BTU/WATT-HR) 4.43 4.91 5.38 5.85 6.32 6.82 7.35 7.9 8.5 9.14 9.82 10.55 11.34 12.18
Current (AMPS) 9.48 10.3 11.02 11.65 12.19 12.66 13.04 13.36 13.62 13.81 13.96 14.05 14.1 14.12

 

06DR541 R404A/R507 Refrigerants

Physical Data
Model Nominal HP Displ. CFM No. of Cylinders Suction Line Size (in) Discharge Line Size (in) Shipping Weight (lbs) Oil Charge (pints)
06DR541 15 41 6 1 5/8 1 1/8 325 8

 

Available Voltages
208/230-3-60
460-3-60
575-3-60

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 12

 

Tabular Data Summary – Fixed RGT = 65°F Subcooling = 0°F Voltage: 460-3-60Hz
Saturated Condensing Temperature (F) Saturated Suction Temperature (F)
-10 -5 0 5 10 15 20 25 30 35 40 45 50 55
90 Capacity (Btu/hr) 43729 50724 58399 66821 76059 86181 97257 109354 122542 136889 152464 169335 187571 207240
Power (kW) 5.66 6.03 6.38 6.71 7.02 7.32 7.6 7.85 8.09 8.31 8.51 8.69 8.85 8.99
EER (BTU/WATT-HR) 7.72 8.41 9.16 9.96 10.83 11.77 12.8 13.92 15.14 16.47 17.91 19.48 21.19 23.04
Current (AMPS) 9.66 10.26 10.79 11.26 11.67 12.03 12.34 12.62 12.86 13.07 13.26 13.44 13.61 13.77
110 Capacity (Btu/hr) 35659 42285 49461 57255 65736 74973 85034 95988 107903 120848 134891 150102 166549 184300
Power (kW) 6.04 6.55 7.03 7.5 7.95 8.38 8.79 9.17 9.54 9.89 10.22 10.52 10.81 11.07
EER (BTU/WATT-HR) 5.9 6.46 7.03 7.63 8.27 8.95 9.68 10.46 11.31 12.22 13.2 14.26 15.41 16.64
Current (AMPS) 10.17 10.94 11.62 12.21 12.73 13.18 13.56 13.89 14.16 14.39 14.58 14.74 14.86 14.97
130 Capacity (Btu/hr) 27167 33382 40017 47142 54824 63133 72138 81906 92506 104007 116478 129987 144603 160394
Power (kW) 6.13 6.79 7.44 8.06 8.67 9.25 9.82 10.36 10.88 11.38 11.86 12.32 12.75 13.16
EER (BTU/WATT-HR) 4.43 4.91 5.38 5.85 6.32 6.82 7.35 7.9 8.5 9.14 9.82 10.55 11.34 12.18
Current (AMPS) 10.43 11.33 12.12 12.81 13.41 13.92 14.35 14.7 14.98 15.19 15.35 15.46 15.52 15.53

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 13

 

 

R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 14R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 15R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 16R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 17R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 18R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 19R134A 575V Power Supply Cold Storage Compressor With 2 Cylinders 20