Place of Origin: | Shanghai China |
Brand Name: | LU-VE |
Model Number: | S2HC38E65 |
Minimum Order Quantity: | 1 |
---|---|
Price: | negotiable |
Packaging Details: | Plywood pallet+Carton |
Supply Ability: | 50 units per month |
Brand Name: | LU-VE | Application: | Cold Storage Room Freeze |
---|---|---|---|
Refrigerant: | R404A/R134A/R22/R507C | Voltage: | 220-240V/50-60HZ |
Weight: | 32KG | Size: | 1048*445*490mm |
High Light: | S2HC31E80,Stainless Steel Cool Room Evaporators,220V Cool Room Evaporators |
S2HC38E65 220V Cool Room Evaporators Stainless Steel Compact Unit evaporator for freezer
1.its crust is made up of ginning aluminum sheet;
2.its frost is well-distributed, defrost with high-efficiency.
No. | Model | capacity | No. | Model | capacity | No. | Model | capacity |
1 | S2HC-36-50 | 2HP | 1 | S2HC28-65 | 2HP | 1 | S2HC23-80 | 2HP |
2 | S2HC-49-50 | 3HP | 2 | S2HC38-65 | 3HP | 2 | S3HC31-80 | 3HP |
3 | S2HC-71-50 | 3.5HP | 3 | S2HC55-65 | 3.5HP | 3 | S2HC36-80 | 3.5HP |
4 | S2HC-107-50 | 4HP | 4 | S2HC85-65 | 4HP | 4 | S2HC70-80 | 4HP |
5 | S2HC-142-50 | 5HP | 5 | S2HC110-65 | 5HP | 5 | S2HC92-80 | 5HP |
6 | S3HC-73-50 | 3.5HP | 6 | S2HC59-65 | 3.5HP | 6 | S3HC47-80 | 3.5HP |
7 | S3HC-106-50 | 4HP | 7 | S2HC84-65 | 4HP | 7 | S3HC69-80 | 4HP |
8 | S3HC-133-50 | 4.5HP | 8 | S2HC108-65 | 4.5HP | 8 | S3HC86-80 | 4.5HP |
9 | S3HC-145-50 | 5HP | 9 | S2HC117-65 | 5HP | 9 | S3HC94-80 | 5HP |
10 | S3HC-215-50 | 8HP | 10 | S2HC174-65 | 8HP | 10 | S3HC143-80 | 8HP |
11 | S3HC-272-50 | 10HP | 11 | S2HC218-65 | 10HP | 11 | S3HC179-80 | 10HP |
12 | S3HC-323-50 | 12HP | 12 | S2HC261-65 | 12HP | 12 | S3HC213-80 | 12HP |
13 | S3HC-362-50 | 13HP | 13 | S2HC290-65 | 13HP | 13 | S3HC238-80 | 13HP |
14 | S3HC-430-50 | 15HP | 14 | S2HC348-65 | 15HP | 14 | S3HC284-80 | 15HP |
Performance
The refrigerating capacity of the evaporator is tested under dry conditionson the basis of ENV328. Listed on the sample of the evaporator capacity (latent heat +measurable refrigerating capacity )is refrigerantR404A,humidity working condition is libary temperature2.5℃,evaporation temperature 7.5℃,DT=10k.Taking into account the increase of the cooling amount (latent heat )caused by the condensation of water pavor on the surface of the avaporator ,the value of the is1.25 times that of the refrigerating amount (latent heat coefficent)in the dry environment ,and the value of latent heat coefficient depends on the actual working condition of the cold storage ,while the coefficient of the high temperature cold storage increases.The coefficient of cryogenic cold storage decreases .As shown in the chart on the right.
Contact Person: Manager
Address: No. 328 on the 4th plant hengyong Road, Jiading District, Shanghai
Factory Address:No. 328 on the 4th plant hengyong Road, Jiading District, Shanghai