Product Details
Standard Motor 380V/3/50Hz-460/3/60Hz Refrigerant R22/R404A
Quality Assurance A Year Nominal HP Describe
High Light

R22 Screw Refrigeration Compressor

,

Screw Refrigeration Compressor 380V

,

145m3/H Displacement Screw Refrigeration Compressor

Leave a Message
Product Description

 

R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 0

 

Model SLG 100-35 120-40 140-50 190-65 210-70 230-80 290-100 320-110 350-120 370-130 420-145 470-160 520-180 570-195 640-210
Displacement 50Hz m3/h 102 128 145 188 205 235 293 322 354 368 416 469 520 572 641
Nominal Motor Power Hp/kW 40/30 40/30 50/37 70/52 70/52 80/60 100/75 115/83 120/89 130/98 145/108 160/120 180/135 195/146 210/157
Weight Kg 245 245 255 405 410 420 535 540 545 665 675 710 1030 1050 1050
Discharge line, internal mm 45 45 45 57 57 57 57 57 57 76 76 76 76 76 76
Suction line, internal mm 57 57 57 76 76 76 89 89 89 89 89 89 108 108 108
Energy regulation 40%,70%,100%
Protection module INT 69 RCY
Standard motor 380V/3/50Hz-460/3/60Hz
Starting current A 134 134 139 193 193 298 338 354 366 453 453 543 595 678 767
A 134 134 182 139 193 338 318 318 354 374 453 543 595 595 595
Maximum working current A 56 60 78 104 109 126 158 175 187 206 228 253 284 308 331

 

R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 1R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 2

 

 

 

PERFORMANCES  SLG R22

SLG 100-35(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 42.5 17.4 40.1 19.2 37.4 21.6 34.3 21.9 30.8 24.3
-15 52.2 17.6 49.2 19.2 45.9 21.6 42.2 22.4 38.2 24.9
-10 63.5 17.7 60.0 19.4 56.1 21.7 51.9 22.9 47.5 25.4 38.2 31.1
-5 76.3 18.0 72.3 19.8 68.0 21.8 63.4 23.4 58.8 25.9 48.7 31.8
0 90.7 18.4 86.3 20.1 81.6 22.1 76.8 23.9 71.8 26.5 61.5 32.6
5 106.5 18.7 101.8 20.4 96.9 22.6 91.9 24.5 86.7 27.1
10 118.9 21.1 113.9 23.2 108.8 25.0 103.5 27.8

 

SLG 100 -35(R22)ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 49.0 18.7 47.8 20.9 46.1 23.8 44.0 25.1 41.2 27.8
-15 58.7 18.9 57.1 21.0 55.0 23.9 52.5 25.2 49.4 27.9
-10 69.4 19.1 67.5 21.0 65.3 23.9 62.6 25.3 59.4 28.0 52.0 34.2
-5 81.2 19.1 79.3 21.2 76.9 24.0 74.2 25.6 71.1 28.1 64.0 34.6
0 94.0 19.2 92.0 21.3 89.6 23.9 87.1 25.8 84.3 28.2 77.8 34.8
5 107.4 19.3 109.6 21.5 106.6 24.1 101.2 26.0 98.6 28.4
10 126.7 22.1 124.7 24.3 120.6 26.6 114.1 28.6

 

SLG 230 -80(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 99.8 40.9 94.2 45.1 87.8 50.8 80.5 51.5 72.5 57.2
-15 122.8 41.4 115.7 45.1 107.8 50.8 99.2 52.5 89.9 58.4
-10 149.3 41.6 140.9 45.6 131.7 51.0 122.0 53.8 111.7 59.6 89.7 73.2
-5 179.4 42.3 169.8 46.5 159.8 51.2 149.1 55.0 138.1 60.8 114.5 74.8
0 213.2 43.2 202.7 47.2 191.7 51.9 180.5 56.2 168.7 62.2 144.4 76.6
5 250.4 44.1 239.2 47.9 227.8 53.1 216.0 57.6 203.9 63.7
10 279.5 49.5 267.6 54.5 255.6 58.8 243.3 65.3

 

SLG 230 -80 (R22) ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 115.1 43.9 112.2 49.1 108.4 55.9 103.3 59.0 96.9 65.3
-15 137.9 44.4 134.1 49.4 129.2 56.0 123.4 59.2 116.1 65.6
-10 163.2 44.9 158.7 49.4 153.4 56.2 147.2 59.5 139.6 65.8 122.2 80.4
-5 190.9 44.9 186.2 49.8 180.7 56.3 174.3 60.2 167.2 66.0 150.4 81.3
0 220.8 45.1 216.1 50.1 210.6 56.1 204.7 60.6 198.0 66.3 182.9 81.8
5 252.3 45.4 257.6 50.5 250.5 56.6 237.7 61.1 231.8 66.7
10 297.7 51.9 293.0 57.1 283.4 62.5 268.2 67.2

 

SLG120-40(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 51.8 21.2 48.9 23.4 45.6 26.4 41.8 26.8 37.6 29.7
-15 63.7 21.5 60.0 23.4 56.0 26.4 51.5 27.3 46.7 30.3
-10 77.5 21.6 73.1 23.7 68.4 26.5 63.3 27.9 58.0 31.0 46.6 38.0
-5 93.1 22.0 88.2 24.2 82.9 26.6 77.4 28.5 71.7 31.6 59.5 38.8
0 110.7 22.4 105.2 24.5 99.5 27.0 93.7 29.2 87.6 32.3 75.0 39.8
5 130.0 22.9 124.2 24.9 118.2 27.6 112.1 29.9 105.8 33.0
10 145.1 25.7 138.9 28.3 132.7 30.5 126.3 33.9

 

SLG 120-40(R22)ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 59.8 22.8 58.3 25.5 56.3 29.0 53.6 30.6 50.3 33.9
-15 71.6 23.1 69.6 25.6 67.1 29.1 64.0 30.7 60.3 34.0
-10 84.7 23.3 82.4 25.6 79.6 29.2 76.4 30.9 72.5 34.2 63.4 41.7
-5 99.1 23.3 96.7 25.9 93.8 29.2 90.5 31.2 86.8 34.3 78.1 42.2
0 114.6 23.4 112.2 26.0 109.3 29.1 106.3 31.5 102.8 34.4 95.0 42.5
5 131.0 23.5 133.7 26.2 130.1 29.4 123.4 31.7 120.3 34.6
10 154.6 27.0 152.1 29.6 147.1 32.5 139.3 34.9

 

SLG 290-100(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 125.3 51.3 118.2 56.6 110.2 63.7 101.1 64.7 91.0 71.8
-15 154.1 51.9 145.2 56.6 135.3 63.7 124.5 66.0 112.8 73.3
-10 187.4 52.2 176.9 57.2 165.4 64.0 153.2 67.5 140.3 74.8 112.6 91.8
-5 225.2 53.1 213.2 58.4 200.5 64.3 187.2 69.0 173.3 76.4 143.8 93.9
0 267.6 54.3 254.5 59.3 240.7 65.2 226.6 70.5 211.8 78.1 181.3 96.2
5 314.3 55.3 300.2 60.1 285.9 66.7 271.1 72.3 255.9 79.9
10 350.9 62.2 335.9 68.4 320.9 73.8 305.4 81.9

 

SLG 290-100(R22) ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 144.5 55.2 140.9 61.7 136.1 70.2 129.7 74.0 121.6 82.0
-15 173.2 55.8 168.4 62.0 162.2 70.4 154.8 74.3 145.8 82.3
-10 204.9 56.3 199.2 62.0 192.6 70.5 184.7 74.6 175.3 82.6 153.4 100.9
-5 239.6 56.3 233.8 62.5 226.9 70.7 218.8 75.5 209.9 82.9 188.8 102.1
0 277.2 56.6 271.3 62.8 264.3 70.4 257.0 76.1 248.5 83.2 229.6 102.7
5 316.8 56.9 323.3 63.4 314.5 71.1 298.4 76.7 291.0 83.8
10 373.8 65.2 367.9 71.7 355.8 78.5 336.7 84.4

 

SLG 140-50(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 60.3 24.7 56.9 27.3 53.1 30.7 48.7 31.1 43.8 34.6
-15 74.2 25.0 69.9 27.3 65.1 30.7 60.0 31.8 54.3 35.3
-10 90.2 25.1 85.1 27.5 79.6 30.8 73.7 32.5 67.5 36.0 54.2 44.2
-5 108.4 25.6 102.6 28.1 96.5 31.0 90.1 33.2 83.4 36.8 69.2 45.2
0 128.8 26.1 122.5 28.5 115.8 31.4 109.1 33.9 102.0 37.6 87.3 46.3
5 151.3 26.6 144.5 28.9 137.6 32.1 130.5 34.8 123.2 38.5
10 168.9 29.9 161.7 32.9 154.5 35.5 147.0 39.4

 

SLG 140-50 (R22) ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 69.6 26.6 67.8 29.7 65.5 33.8 62.4 35.6 58.5 39.5
-15 83.4 26.8 81.0 29.8 78.1 33.9 74.5 35.8 70.2 39.6
-10 98.6 27.1 95.9 29.8 92.7 33.9 88.9 35.9 84.4 39.8 73.8 48.6
-5 115.3 27.1 112.5 30.1 109.2 34.0 105.3 36.4 101.0 39.9 90.9 49.1
0 133.4 27.3 130.6 30.2 127.2 33.9 123.7 36.6 119.6 40.0 110.5 49.4
5 152.5 27.4 155.6 30.5 151.4 34.2 143.7 36.9 140.1 40.3
10 179.9 31.4 177.1 34.5 171.3 37.8 162.1 40.6

 

SLG 320-110(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 138.4 56.7 130.6 62.6 121.8 70.4 111.7 71.5 100.6 79.3
-15 170.3 57.4 160.4 62.6 149.6 70.4 137.6 72.9 124.7 81.0
-10 207.1 57.7 195.4 63.2 182.7 70.7 169.3 74.6 155.0 82.7 124.4 101.5
-5 248.8 58.7 235.6 64.5 221.6 71.1 206.8 76.3 191.5 84.4 158.9 103.7
0 295.7 60.0 281.2 65.5 265.9 72.0 250.4 77.9 234.1 86.4 200.4 106.3
5 347.3 61.1 331.8 66.4 316.0 73.7 299.6 79.9 282.8 88.3
10 387.8 68.7 371.2 75.6 354.6 81.5 337.5 90.6

 

SLG 320 -110 (R22) ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 159.7 61.0 155.7 68.1 150.4 77.6 143.3 81.8 134.4 90.6
-15 191.4 61.6 186.1 68.5 179.2 77.8 171.1 82.2 161.1 91.0
-10 226.4 62.3 220.2 68.5 212.8 77.9 204.2 82.5 193.7 91.3 169.5 111.5
-5 264.8 62.3 258.4 69.1 250.7 78.1 241.8 83.5 231.9 91.6 208.6 112.8
0 306.3 62.6 299.8 69.4 292.1 77.8 284.0 84.1 274.7 91.9 253.8 113.4
5 350.1 62.9 357.3 70.1 347.5 78.6 329.8 84.8 321.6 92.6
10 413.0 72.0 406.5 79.2 393.2 86.7 372.1 93.2

 

SLG 190-65(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 84.1 34.1 79.3 37.6 74.0 42.3 67.9 43.0 61.1 47.7
-15 103.4 34.5 97.4 37.6 90.8 42.3 83.6 43.8 75.7 48.7
-10 125.8 34.7 118.7 38.0 111.0 42.5 102.8 44.8 94.1 49.7 75.6 61.0
-5 151.1 35.3 143.1 38.8 134.6 42.7 125.6 45.8 116.3 50.7 96.5 62.4
0 179.6 36.1 170.8 39.4 161.5 43.3 152.1 46.9 142.2 51.9 121.7 63.9
5 211.0 36.7 201.5 39.9 191.9 44.3 182.0 48.0 171.8 53.1
10 235.5 41.3 225.4 45.5 215.4 49.0 205.0 54.4

 

SLG 190-65 (R22) ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 94.1 35.5 91.7 39.7 88.6 45.2 84.4 47.7 79.1 52.8
-15 112.7 35.9 109.6 39.9 105.5 45.3 100.8 47.9 94.9 53.0
-10 133.3 36.3 129.7 39.9 125.4 45.4 120.2 48.1 114.1 53.2 99.8 65.0
-5 155.9 36.3 152.2 40.3 147.7 45.5 142.4 48.6 136.6 53.4 122.9 65.7
0 180.4 36.5 176.6 40.5 172.0 45.4 167.3 49.0 161.8 53.6 149.5 66.1
5 206.2 36.7 210.4 40.9 204.7 45.8 194.2 49.4 189.4 54.0
10 243.3 42.0 239.4 46.2 231.6 50.5 219.1 54.3

 

SLG 350-120(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 152.8 62.6 144.3 69.1 134.5 77.8 123.4 78.9 111.1 87.6
-15 188.1 63.4 177.2 69.1 165.2 77.8 152.0 80.5 137.7 89.5
-10 228.7 63.7 215.8 69.8 201.8 78.1 186.9 82.4 171.2 91.3 137.4 112.1
-5 274.8 64.8 260.2 71.3 244.7 78.5 228.4 84.2 211.5 93.2 175.5 114.6
0 326.6 66.2 310.6 72.4 293.7 79.6 276.5 86.1 258.5 95.4 221.3 117.3
5 383.6 67.5 366.4 73.4 348.9 81.4 330.9 88.2 312.3 97.5
10 428.2 75.9 409.9 83.5 391.6 90.0 372.7 100.0

 

SLG 350-120 (R22) ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 176.4 67.3 171.9 75.2 166.1 85.7 158.3 90.4 148.4 100.1
-15 211.3 68.0 205.5 75.6 197.9 85.9 189.0 90.7 177.9 100.4
-10 250.0 68.8 243.2 75.6 235.0 86.0 225.4 91.1 213.9 100.8 187.1 123.1
-5 292.4 68.8 285.3 76.3 276.9 86.2 267.1 92.2 256.1 101.2 230.4 124.6
0 338.3 69.1 331.1 76.7 322.6 85.9 313.6 92.9 303.3 101.5 280.2 125.3
5 386.6 69.5 394.6 77.4 383.8 86.8 364.2 93.6 355.1 102.2
10 456.1 79.6 448.9 87.5 434.2 95.8 410.9 103.0

 

SLG 210-70(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 89.2 36.5 84.2 40.3 78.5 45.4 72.0 46.1 64.8 51.1
-15 109.7 37.0 103.4 40.3 96.3 45.4 88.7 47.0 80.3 52.2
-10 133.4 37.2 125.9 40.7 117.7 45.6 109.0 48.0 99.8 53.3 80.1 65.4
-5 160.3 37.8 151.8 41.6 142.8 45.8 133.2 49.1 123.4 54.4 102.4 66.8
0 190.5 38.6 181.2 42.2 171.3 46.4 161.3 50.2 150.8 55.6 129.1 68.4
5 223.7 39.4 213.7 42.8 203.5 47.5 193.0 51.5 182.2 56.9
10 249.8 44.2 239.1 48.7 228.4 52.5 217.4 58.3

 

SLG 210 -70 (R22) ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 102.9 39.3 100.3 43.9 96.9 50.0 92.3 52.7 86.5 58.4
-15 123.3 39.7 119.9 44.1 115.4 50.1 110.2 52.9 103.8 58.6
-10 145.8 40.1 141.8 44.1 137.1 50.2 131.5 53.1 124.8 58.8 109.2 71.8
-5 170.6 40.1 166.4 44.5 161.5 50.3 155.8 53.8 149.4 59.0 134.4 72.7
0 197.3 40.3 193.1 44.7 188.2 50.1 182.9 54.2 176.9 59.2 163.5 73.1
5 225.5 40.5 230.2 45.2 223.9 50.6 212.4 54.6 207.2 59.6
10 266.1 46.4 261.9 51.0 253.3 55.9 239.7 60.1

 

SLG 370-130(R22)
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 159.2 65.3 150.3 72.0 140.1 81.0 128.5 82.2 115.7 91.3
-15 195.9 66.0 184.6 72.0 172.0 81.0 158.3 83.9 143.4 93.2
-10 238.2 66.4 224.8 72.8 210.2 81.4 194.7 85.8 178.3 95.1 143.1 116.7
-5 286.2 67.5 271.0 74.3 254.9 81.8 237.9 87.7 220.3 97.1 182.8 119.3
0 340.2 69.0 323.5 75.4 305.9 82.9 288.0 89.7 269.2 99.3 230.5 122.2
5 399.5 70.3 381.6 76.4 363.5 84.8 344.7 91.9 325.3 101.6
10 446.0 79.0 427.0 87.0 407.9 93.8 388.2 104.2

 

SLG 370-130 (R22) ECO
Tc 30 35 40 45 50 60
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 183.7 70.1 179.1 78.4 173.0 89.3 164.9 94.1 154.5 104.3
-15 220.1 70.9 214.0 78.8 206.1 89.4 196.8 94.5 185.3 104.6
-10 260.4 71.6 253.3 78.8 244.8 89.6 234.8 94.9 222.8 105.0 194.9 128.3
-5 304.6 71.6 297.2 79.5 288.4 89.8 278.2 96.0 266.8 105.4 240.0 129.8
0 352.4 72.0 344.9 79.9 336.0 89.5 326.7 96.8 315.9 105.8 291.9 130.5
5 402.7 72.4 411.0 80.6 399.8 90.4 379.4 97.5 369.9 106.5
10 475.1 82.9 467.6 91.1 452.3 99.8 428.0 107.3

 

 

PERFORMANCES SLG R404A

SLG 100-35(R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 49.2 17.4 43.5 20.4 41.2 22.6 37.4 24.9 32.6 27.8 28.0 30.5
-15 61.5 17.8 53.5 20.6 51.8 23.1 46.2 25.3 40.2 28.6 35.8 31.1
-10 76.0 18.2 66.8 21.2 62.5 23.6 56.8 25.8 51.2 29.2 45.7 31.9
-5 90.5 18.6 80.7 21.9 75.3 24.2 69.3 26.5 62.8 29.7 55.6 32.5
0 96.9 22.7 91.4 24.8 84.2 27.0 76.7 30.2 71.0 33.2
5 116.5 23.5 107.2 25.3 100.5 27.8 92.6 30.5 83.1 33.7

 

SLG 100-35 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 60.4 18.6 59.0 22.7 56.7 25.4 53.5 28.6 48.9 31.5 47.6 36.2
-15 72.2 18.8 69.5 22.9 66.7 25.6 62.9 28.8 58.2 31.7 57.2 36.5
-10 85.3 19.1 81.3 23.2 78.1 25.7 73.9 29.0 68.9 31.8 67.4 36.6
-5 99.5 19.2 94.3 23.5 90.8 25.9 86.4 29.2 81.1 32.2 77.2 36.8
0 108.5 23.7 104.5 26.1 100.3 29.3 94.6 32.5 90.6 36.7
5 123.3 23.8 119.1 26.2 114.7 29.3 109.1 32.6 103.2 36.9

 

SLG 230-80(R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 116.6 39.6 103.1 46.4 97.6 51.4 88.6 56.6 77.3 63.2 66.3 69.4
-15 145.8 40.5 126.8 46.8 122.8 52.5 109.5 57.5 95.3 65.0 84.9 70.7
-10 180.1 41.4 158.3 48.2 148.1 53.7 134.6 58.7 121.3 66.4 108.3 72.5
-5 214.5 42.3 191.3 49.8 178.5 55.0 164.2 60.3 148.8 67.5 131.8 73.9
0 229.7 51.6 216.6 56.4 199.6 61.4 181.8 68.7 168.4 75.5
5 276.1 53.4 254.1 57.5 238.2 63.2 219.5 69.4 196.9 76.6

 

SLG 230-80 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 143.2 42.3 139.7 51.6 134.4 57.8 126.7 65.0 116.0 71.6 112.8 82.3
-15 171.1 42.8 164.6 52.1 158.0 58.2 149.2 65.5 137.9 72.1 135.6 83.0
-10 202.2 43.4 192.7 52.8 185.2 58.4 175.2 66.0 163.3 72.3 159.7 83.2
-5 235.8 43.7 223.5 53.4 215.2 58.9 204.8 66.4 192.2 73.2 183.0 83.7
0 257.1 53.9 247.5 59.4 237.7 66.6 224.1 73.9 214.7 83.5
5 292.3 54.1 282.4 59.6 271.8 66.6 258.6 74.1 244.7 83.9

 

SLG 120-40(R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 60.5 21.4 53.5 25.1 50.7 27.8 46.0 30.6 40.1 34.2 34.4 37.5
-15 75.6 21.9 65.8 25.3 63.7 28.4 56.8 31.1 49.4 35.2 44.1 38.3
-10 93.5 22.4 82.2 26.1 76.9 29.0 69.9 31.7 63.0 35.9 56.2 39.2
-5 111.3 22.9 99.3 26.9 92.6 29.8 85.2 32.6 77.2 36.5 68.4 40.0
0 119.2 27.9 112.4 30.5 103.6 33.2 94.3 37.1 87.4 40.8
5 143.3 28.9 131.9 31.1 123.6 34.2 113.9 37.5 102.2 41.5

 

SLG 120-40 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 74.3 22.9 72.5 27.9 69.8 31.2 65.8 35.2 60.2 38.7 58.5 44.5
-15 88.8 23.1 85.4 28.2 82.0 31.5 77.4 35.4 71.6 39.0 70.4 44.9
-10 104.9 23.5 100.0 28.5 96.1 31.6 90.9 35.7 84.7 39.1 82.9 45.0
-5 122.4 23.6 116.0 28.9 111.7 31.9 106.3 35.9 99.7 39.6 95.0 45.3
0 133.5 29.2 128.5 32.1 123.3 36.0 116.3 40.0 111.4 45.1
5 151.7 29.3 146.5 32.2 141.0 36.0 134.2 40.1 127.0 45.4

 

SLG 290-100(R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 147.0 49.9 130.0 58.5 123.1 64.8 111.8 71.4 97.4 79.7 83.6 87.5
-15 183.8 51.0 159.9 59.1 154.8 66.2 138.1 72.5 120.1 82.0 107.0 89.2
-10 227.1 52.2 199.6 60.8 186.8 67.7 169.7 74.0 153.0 83.7 136.5 91.5
-5 270.4 53.3 241.2 62.8 225.0 69.4 207.1 76.0 187.7 85.2 166.1 93.2
0 289.6 65.1 273.1 71.1 251.6 77.4 229.2 86.6 212.3 95.2
5 348.1 67.4 320.3 72.5 300.3 79.7 276.7 87.5 248.3 96.6

 

SLG 290-100 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 180.5 53.3 176.2 65.1 169.5 72.8 159.7 82.0 146.2 90.3 142.2 103.8
-15 215.7 53.9 207.6 65.7 199.3 73.4 188.1 82.6 173.9 90.9 170.9 104.7
-10 254.9 54.8 243.0 66.5 233.5 73.7 220.9 83.2 205.9 91.2 201.4 105.0
-5 297.3 55.1 281.8 67.4 271.3 74.3 258.2 83.7 242.3 92.3 230.7 105.5
0 324.2 68.0 312.1 74.8 299.7 84.0 282.6 93.2 270.7 105.2
5 368.5 68.2 356.0 75.1 342.6 84.0 326.1 93.5 308.5 105.8

 

SLG 140-50 (R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 70.8 25.1 62.6 29.4 59.3 32.5 53.9 35.9 46.9 40.0 40.3 43.9
-15 88.6 25.6 77.0 29.7 74.6 33.3 66.5 36.4 57.9 41.2 51.6 44.8
-10 109.4 26.2 96.2 30.5 90.0 34.0 81.8 37.2 73.7 42.0 65.8 45.9
-5 130.3 26.8 116.2 31.5 108.4 34.8 99.8 38.2 90.4 42.8 80.1 46.8
0 139.5 32.7 131.6 35.7 121.2 38.9 110.4 43.5 102.3 47.8
5 167.8 33.8 154.4 36.4 144.7 40.0 133.3 43.9 119.7 48.5

 

SLG 140-50 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 87.0 26.8 84.9 32.7 81.7 36.6 77.0 41.2 70.5 45.4 68.5 52.1
-15 103.9 27.1 100.0 33.0 96.0 36.9 90.6 41.5 83.8 45.6 82.4 52.6
-10 122.9 27.5 117.1 33.4 112.5 37.0 106.5 41.8 99.2 45.8 97.1 52.7
-5 143.3 27.6 135.8 33.8 130.8 37.3 124.4 42.0 116.8 46.4 111.2 53.0
0 156.2 34.1 150.4 37.6 144.4 42.2 136.2 46.8 130.5 52.8
5 177.6 34.3 171.6 37.7 165.1 42.2 157.1 46.9 148.7 53.1

 

SLG 320-110 (R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 162.2 55.1 143.4 64.5 135.9 71.5 123.3 78.8 107.5 88.0 92.3 96.5
-15 202.8 56.3 176.4 65.2 170.8 73.1 152.3 80.1 132.6 90.5 118.1 98.4
-10 250.6 57.6 220.3 67.1 206.1 74.7 187.3 81.6 168.8 92.4 150.6 100.9
-5 298.4 58.9 266.1 69.3 248.3 76.6 228.5 83.9 207.1 94.0 183.3 102.8
0 319.5 71.8 301.4 78.5 277.6 85.4 252.9 95.6 234.3 105.1
5 384.1 74.4 353.5 80.1 331.4 88.0 305.3 96.5 274.0 106.6

 

SLG 320-110 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 199.2 58.9 194.4 71.8 187.0 80.4 176.3 90.5 161.4 99.7 157.0 114.5
-15 238.0 59.5 229.1 72.5 219.9 81.0 207.5 91.1 191.9 100.3 188.6 115.5
-10 281.3 60.4 268.1 73.4 257.6 81.3 243.8 91.8 227.2 100.6 222.2 115.8
-5 328.1 60.8 310.9 74.4 299.4 82.0 284.9 92.4 267.4 101.9 254.6 116.4
0 357.8 75.0 344.4 82.6 330.7 92.7 311.8 102.8 298.7 116.1
5 406.6 75.3 392.9 82.9 378.1 92.7 359.8 103.2 340.4 116.8

 

SLG 190-65(R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 97.4 33.1 86.1 38.8 81.6 42.9 74.1 47.3 64.5 52.8 55.4 58.0
-15 121.8 33.8 105.9 39.1 102.6 43.9 91.5 48.1 79.6 54.3 70.9 59.1
-10 150.5 34.6 132.3 40.3 123.8 44.8 112.5 49.0 101.4 55.5 90.4 60.6
-5 179.2 35.3 159.8 41.6 149.1 46.0 137.2 50.4 124.3 56.4 110.1 61.8
0 191.9 43.1 181.0 47.1 166.7 51.3 151.9 57.4 140.7 63.1
5 230.7 44.7 212.3 48.1 199.0 52.8 183.3 58.0 164.5 64.0

 

SLG 190-65 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 119.6 35.3 116.7 43.1 112.3 48.3 105.8 54.3 96.9 59.9 94.2 68.8
-15 142.9 35.7 137.5 43.5 132.0 48.6 124.6 54.7 115.2 60.2 113.3 69.4
-10 168.9 36.3 161.0 44.1 154.7 48.8 146.4 55.1 136.4 60.4 133.5 69.5
-5 197.0 36.5 186.7 44.7 179.8 49.2 171.1 55.5 160.6 61.2 152.9 69.9
0 214.8 45.0 206.8 49.6 198.6 55.7 187.2 61.8 179.4 69.7
5 244.2 45.2 235.9 49.8 227.0 55.7 216.1 61.9 204.4 70.1

 

SLG 350-120 (R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 177.4 60.2 156.9 70.6 148.6 78.2 134.9 86.2 117.6 96.2 100.9 105.6
-15 221.8 61.6 192.9 71.3 186.8 79.9 166.6 87.6 145.0 99.0 129.2 107.6
-10 274.1 63.0 240.9 73.4 225.4 81.7 204.9 89.3 184.7 101.1 164.7 110.4
-5 326.4 64.4 291.0 75.8 271.6 83.8 249.9 91.7 226.5 102.8 200.5 112.5
0 349.5 78.6 329.6 85.8 303.7 93.4 276.6 104.5 256.2 114.9
5 420.2 81.3 386.6 87.6 362.5 96.2 334.0 105.6 299.7 116.6

 

SLG 350-120 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 217.9 64.4 212.6 78.6 204.6 87.9 192.8 99.0 176.5 109.0 171.7 125.3
-15 260.3 65.1 250.5 79.3 240.5 88.6 227.0 99.7 209.9 109.7 206.3 126.3
-10 307.7 66.1 293.3 80.3 281.8 88.9 266.6 100.4 248.5 110.1 243.1 126.7
-5 358.8 66.4 340.1 81.3 327.5 89.6 311.6 101.1 292.4 111.4 278.4 127.4
0 391.3 82.0 376.7 90.3 361.7 101.4 341.1 112.5 326.8 127.0
5 444.7 82.4 429.7 90.7 413.5 101.4 393.6 112.8 372.3 127.7

 

SLG 210-70 (R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 103.3 35.1 91.4 41.1 86.5 45.5 78.5 50.2 68.5 56.0 58.8 61.5
-15 129.2 35.9 112.4 41.5 108.8 46.6 97.0 51.0 84.4 57.6 75.2 62.7
-10 159.6 36.7 140.3 42.7 131.3 47.6 119.3 52.0 107.5 58.8 95.9 64.3
-5 190.1 37.5 169.5 44.1 158.1 48.8 145.5 53.4 131.9 59.9 116.8 65.5
0 203.5 45.7 191.9 50.0 176.8 54.4 161.1 60.9 149.2 66.9
5 244.7 47.4 225.1 51.0 211.1 56.0 194.5 61.5 174.5 67.9

 

SLG 210-70 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 126.9 37.5 123.8 45.7 119.1 51.2 112.3 57.6 102.8 63.5 100.0 72.9
-15 151.6 37.9 145.9 46.1 140.0 51.6 132.2 58.0 122.2 63.9 120.1 73.6
-10 179.2 38.5 170.8 46.8 164.1 51.8 155.2 58.4 144.7 64.1 141.5 73.8
-5 208.9 38.7 198.0 47.4 190.7 52.2 181.5 58.8 170.3 64.9 162.1 74.2
0 227.8 47.8 219.3 52.6 210.6 59.0 198.6 65.5 190.3 74.0
5 259.0 48.0 250.2 52.8 240.8 59.0 229.2 65.7 216.8 74.4

 

SLG 370-130(R404A)
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 187.6 63.7 165.8 74.6 157.1 82.7 142.6 91.1 124.3 101.7 106.7 111.6
-15 234.5 65.1 204.0 75.4 197.5 84.5 176.1 92.6 153.3 104.6 136.6 113.8
-10 289.8 66.6 254.7 77.6 238.3 86.3 216.6 94.4 195.2 106.8 174.2 116.7
-5 345.0 68.0 307.7 80.1 287.1 88.5 264.2 97.0 239.4 108.7 212.0 118.9
0 369.4 83.0 348.5 90.7 321.0 98.8 292.4 110.5 270.9 121.5
5 444.2 86.0 408.7 92.6 383.2 101.7 353.0 111.6 316.8 123.3

 

SLG 370-130 (R404A) ECO
Tc 20 30 35 40 45 50
Te Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa Qo Pa
-20 230.3 68.0 224.8 83.0 216.2 92.9 203.8 104.6 186.6 115.2 181.5 132.4
-15 275.2 68.8 264.9 83.8 254.2 93.7 240.0 105.4 221.9 116.0 218.1 133.5
-10 325.3 69.9 310.0 84.9 297.9 94.0 281.9 106.1 262.7 116.3 257.0 133.9
-5 379.4 70.2 359.5 86.0 346.2 94.8 329.4 106.8 309.1 117.8 294.3 134.6
0 413.7 86.7 398.2 95.5 382.3 107.2 360.5 118.9 345.4 134.3
5 470.2 87.1 454.2 95.9 437.2 107.2 416.1 119.3 393.6 135.0

 

 

 

 

R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 3R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 4R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 5R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 6R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 7R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 8R22 R404A Screw Refrigeration Compressor 380V 145m3/H Displacement 9