XJ W Series Box Type Refrigeration Condensing Unit R404A

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xRefrigerant | R404A | Type | Compressor,condensing Unit |
---|---|---|---|
After-sales Service Provided | Engineers Available To Service Machinery Overseas | Cooling Capacity | From 1800W To 95600W |
Product Name | Cold Storage Mini Refrigeration Unit Bitzer | Application | Cold Storage Room Freezer Room |
Highlight | Box Type Refrigeration Condensing Unit,Refrigeration Condensing Unit R404A,CE Refrigeration Condensing Unit |
XJ W Series Box Type Condensing Units
1. Product description
◆ World famous refrigerant compressor ;
◆ Compact box type construction for easy installation
◆ High efficient and low noise 6 -pole condenser fan motor
◆ Condensing fan motor control available for duo fan units
◆ World famous refrigerant components
◆ With electric control box, and multi protection functions including phase lack, overload, too constant compressor on/off and high/low pressure.
Model | XJWO.6MATY | XJwO1MATY | XJW1.7MATY | XJWO2MATY | XJWO3MATY | ||
Room temperature | -5~5℃ | ||||||
Refrigerant | R404A | ||||||
Power supply | 220V/50Hz | 38oV/50HZ | |||||
Comp | Model | Hermetical | |||||
Type | CAJ9480Z | CAJ9510Z | CAJ4519Z | TFH4524Z | TFH4531Z | ||
Max current(A) | 6.6 | 8 | 15.4 | 6.3 | 8.2 | ||
Con fan | Fan number | 1 | 1 | 1 | 1 | 1 | |
Air flow (m³/h) | 1700 | 1700 | 1700 | 3200 | 3200 | ||
Fan power (w) | 80 | 80 | 80 | 100 | 100 | ||
Fan voltage | 220V/50Hz | ||||||
Cap. & Input | Te0℃ | Cap(W) | 1874 | 2310 | 4070 | 4830 | 6143 |
Input (W) | 820 | 980 | 1850 | 2090 | 2610 | ||
Te-5℃ | Cap(w | 1553 | 1924 | 3340 | 3890 | 4990 | |
lnput(W) | 760 | 910 | 1720 | 1920 | 2385 | ||
Te-10℃ | Cap(W) | 1266 | 1572 | 2700 | 3050 | 3970 | |
Input (W) | 700 | 840 | 1590 | 1740 | 2150 | ||
Pipe | Oversize(LXWXH)mm | 975x450x535 | 975x450x535 | 975x450x535 | 1175x500x635 | 1175x500x635 | |
Installation size(AXB)mm | 650x400 | 650x400 | 650x400 | 800x450 | 800x450 |
Model | XJW01LATY | XJW1.5LATY | XJW02LATY | XJW03LATY | ||
Room temperatur e | -15℃ ~-20 ℃ | |||||
Refriqerant | R404A | |||||
Power supplv | 220V/50HZ | 380/50Hz | ||||
Comp | Model | Hermetical | ||||
Type | CAJ2446Z | CAJ2464Z | TFH2480Z | TFH2511Z | ||
Max current (A) | 7.9 | 10 | 4.8 | 5 | ||
Con fan | Fan number | 1 | 1 | 1 | 1 | |
Air flow (m³/h) | 1700 | 1700 | 3200 | 4600 | ||
Fan power (W) | 80 | 80 | 100 | 160 | ||
Fan voltage | 220V/50HZ | |||||
Cap. & Input | Te-20℃ | Cap(W) | 1296 | 1673 | 2416 | 3348 |
Input(W) | 950 | 1250 | 1837 | 2312 | ||
Te-25℃ | Cap(W) | 1005 | 1300 | 1865 | 2518 | |
Input (W) | 837 | 1100 | 1585 | 1960 | ||
Te-30℃ | Cap(W) | 755 | 990 | 1347 | 1817 | |
lnput (W | 723 | 955 | 1326 | 1635 | ||
Oversize(LXWXH)mm | 975x450x535 | 975X450x535 | 1175X500X635 | 1175x500X635 | ||
lnstallation size(AXB)mm | 650x400 | 650x400 | 80ox450 | 800x450 |
Cooling capacity at condensing temp 45℃
Model | XJW02MAGY | XJW03MAGY | XJW04MAGY | XJW05MAGY | XJW06MAGY | ||
Room temperature | 5℃ ~-15 ℃ | ||||||
Refrigerant | R404A | ||||||
Power supplv | 380V/50 HZ | ||||||
Comp | Model | scroll | |||||
Type | ZB15KQE | ZB21KQE | ZB29KQE | ZB38KQE | ZB45KQE | ||
Max current (A) | 6 | 8 | 11 | 12.5 | 16.1 | ||
Con fan | Fan number | 1 | 1 | 2 | 2 | 2 | |
Air flow (m 3/h) | 3200 | 4600 | 6400 | 9200 | 9200 | ||
Fan power(W) | 100 | 160 | 100×2 | 160×2 | 160×2 | ||
Fan voltage | |||||||
Cap. & Input | Te0℃ | Cap(W) | 4760 | 6990 | 9480 | 11950 | 14000 |
lnput (W) | 1720 | 2480 | 3290 | 4150 | 4700 | ||
Te -5℃ | Cap(W) | 3820 | 5740 | 7790 | 9830 | 11500 | |
lnput (W) | 1760 | 2500 | 3310 | 4180 | 4730 | ||
Te-10℃ | Cap(W) | 3080 | 4680 | 6360 | 8020 | 9380 | |
lnput (W) | 1820 | 2510 | 3330 | 4200 | 4750 | ||
Te-15℃ | Cap(W) | 2430 | 3780 | 5130 | 6480 | 7580 | |
lnnut (W | 1880 | 2510 | 3330 | 4210 | 4760 | ||
Te-20℃ | Cap(W) | 1870 | 3020 | 4100 | 5170 | 6050 | |
lnput (W) | 1930 | 2520 | 3340 | 4210 | 4770 | ||
oversize(LXWXH)mm | 1175x500X635 | 1175x500x635 | 1175x500X1235 | 1175x500X1235 | 1175X500X1235 | ||
Installation size(AXB)mm | 800x450 | 800x450 | 800x450 | 800x450 | 800x450 |
Cooling capacity at condensing temp 45 ℃
Model | XJW02LAGY | XJW03LAGY | XJW04LAGY | XJW05LAGY | XJW06LAGY | ||
Room temperature | -18℃ ~-35 ℃ | ||||||
Refrigerant | R404A | ||||||
Power supply | 380V/3 Phase/50 HZ | ||||||
Comp | Model | Scroll | |||||
Type | ZF06NQE | ZF09NQE | ZF11KQE | ZF15KQE | ZF18NQE | ||
Max current (A) | 5 | 6 | 8 | 10 | 12.5 | ||
Con fan | Fan number | 1 | 1 | 2 | 2 | ||
Air flow (m³/h) | 3200 | 3200 | 4600 | 6400 | 9200 | ||
Fan power(W) | 100 | 100 | 160 | 100×2 | 160×2 | ||
Fan voltage | 220V/50HZ | ||||||
Ca p. & Input | Te-25℃ | Cap(W) | 1710 | 2340 | 2930 | 4130 | 5020 |
Input (w) | 1640 | 2030 | 2460 | 3400 | 4010 | ||
Te-30℃ | Cap(W) | 1370 | 1860 | 2340 | 3270 | 3990 | |
lnput(W) | 1590 | 1990 | 2400 | 3250 | 3880 | ||
Te-35℃ | Cap(w) | 1080 | 1460 | 1850 | 2560 | 3140 | |
Input(w) | 1550 | 1960 | 2350 | 3110 | 3760 | ||
Te-40c | Cap(w) | 830 | 1130 | 1430 | 1960 | 2430 | |
Input(w) | 1510 | 1960 | 2330 | 2950 | 3650 | ||
pipe | Gas (inch) | 3/4SAE | 3/4SAE | 3/4SAE | 7/8SAE | 7/8SAE | |
Liquid (inch) | 3/8SAE | 3/8SAE | 3/8SAE | 1/2SAE | 1/2SAE | ||
Size Drawing | NO.2 | NO.2 | NO.2 | NO.3 | NO.3 |
Model | XJWO8LAGY | XJW10LAGY | XJW13LAGY | ||
Room temperature | -18℃ ~-35℃ | ||||
Refrigerant | R404A | ||||
Power supply | 380V/3Ph/50 Hz | ||||
Comp | Model | Scroll | |||
Type | ZF25KQE | ZF34HQE | ZF41KQE | ||
Max current (A) | 16.1 | 22.6 | 25.1 | ||
Con fan | Fan number | 2 | 2 | 2 | |
Air flow (m3/h) | 9200 | 10580 | 10580 | ||
Fan power (W) | 160×2 | 230×2 | 230×2 | ||
Fan voltage | 220V/50Hz | ||||
Cap. & Input | Te-25℃ | Cap(W) | 6370 | 8750 | 10850 |
Input (w) | 5360 | 7060 | 8920 | ||
Te-30℃ | Cap(W) | 5080 | 6950 | 8640 | |
Input (w) | 5130 | 6700 | 8490 | ||
Te-35℃ | Cap(W) | 3970 | 5430 | 6740 | |
Input (w) | 4880 | 6310 | 8060 | ||
Te-40℃ | Cap(W) | 2980 | 4140 | 5090 | |
Input (W) | 4620 | 5910 | 7620 | ||
Pipe | Gas (inch) | 7/8SAE | 1-1/8ODs | 1-1/8ODs | |
Liquid (inch) | 1/2SAE | 5/8ODS | 5/8ODs |