Home ProductsAir Cooled Condensing Unit

Tag4561Z 5HP Low Temperature Condensing Unit Suitable For Different Refrigerator Long Lifespan

Tag4561Z 5HP Low Temperature Condensing Unit Suitable For Different Refrigerator Long Lifespan

    • Tag4561Z 5HP Low Temperature Condensing Unit Suitable For Different Refrigerator Long Lifespan
    • Tag4561Z 5HP Low Temperature Condensing Unit Suitable For Different Refrigerator Long Lifespan
  • Tag4561Z 5HP Low Temperature Condensing Unit Suitable For Different Refrigerator Long Lifespan

    Product Details:

    Place of Origin: Shanghai, China (Mainland)
    Brand Name: Tecumseh
    Certification: CE
    Model Number: TAG4561Z

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 Unit/Units
    Price: negotiable
    Packaging Details: Plywood pallet+carton
    Supply Ability: 50 units per month
    Contact Now
    Detailed Product Description
    Type: Condensing Unit Refrigerant: R404A/R507C
    Beand: Tecumseh Application: Cold Storage Room/Freezer Room/Chiller
    Voltage: 380V/3PH/50HZ Cooling Capacity: 3.75KW
    High Light:

    compressor condenser unit

    ,

    air cooled condenser

    TAG4561Z 5HP COLD ROOM COMPRESSOR FRENCH TECUMSEH COMPRESSORS & CONDENSING UNITS SERIAL SPECIFICATION

     

    Feature:

     

    1. Tecumseh hermetic compressor

    2. With full range, air cooled & water cooled.

    3. All the accessories are world famous brand, which with reliable quality.

    4. Wide application, suitable for different refrigerant.

    5. Optional configuration is acceptable.

     

    R22 MEDIUM/HIH BACK PRESSURE

     

    Compressor models Nominal Power (HP.)

    Refrig-

    erant

    Displace-

    ment

    (cm³)

    Expansion device Air Flow (m³/hr) Evaporating Temperature Voltage  50HZ
    -25℃ -15℃ -10℃ 0℃ +7.2℃ +15℃
    CAJ 9480TMH/HR 5/8 R22 15.2 CN 1130 576 946 1155 1632 2036 2509 208-220V/1
    TAJ 9480TMH/HR 5/8 R22 15.2 CN 1130 576 946 1155 1632 2036 2509 400V/3
    CAJ 9510TMH/HR 1 R22 18.3 CN 980 711 1126 1374 1941 2411 2987 208-220V/1
    TAJ 9510TMH/HR 1 R22 18.3 CN 980 711 1126 1374 1941 2411 2987 400V/3

    CAJ9513TMH

    /HR

    1-1/8 R22 24.2 CN 980 806 1348 1666 2370 2899 3523 208-220V/1

    TAJ9513TMH

    /HR

    1-1/8 R22 24.2 CN 980 806 1348 1666 2370 2899 3523 400V/3
    CAJ 4517EHR 1-1/4 R22 25.95 CN 2200 1072 1692 2071 2978 3741 4681 208-220V/1
    TAJ 4517TH/HR 1-1/4 R22 25.95 CN 2200 1072 1692 2071 2978 3741 4681 400V/3/
    CAJ 4519TH/HR 1-3/4 R22 34.45 CN 2250 1250 2144 2642 3767 4669 5739 208-220V/1/
    TAJ 4519TH/HR 1-3/4 R22 34.45 CN 2250 1250 2144 2642 3767 4669 5739 400V/3/

    FH 4522FH

    /HR

    2 R22 40.8 CN 2250 1348 2257 2794 4028 5053 6297 208-220V/1/
    TFH 4522FH/HR 2 R22 40.8 CN 2250 1348 2257 2794 4028 5053 6297 400V/3/
    FH 4524FH/HR 2 R22 43.9 CN 2250 1282 2314 2910 4200 5322 6592 208-220V/1
    TFH 4524FH/HR 2 R22 43.9 ON 2250 1282 2314 2910 4200 5322 6592 400V/3/

    FH 4531FH

    /HR

    2-3/4 R22 58.1 CN 4800 1669 3611 4360 6163 7597 9277 208-220V/1
    TFH 4531FH/HR 2-3/4 R22 58.1 CN 4800 1669 3611 4360 6163 7597 9277 400V/3/
    TFH 4540FH/HR 3-1/2 R22 74.25 CN 4600 1890 4157 5137 7438 9194 11300 400V/3/
    TAG 4546THR 4 R22 90.2 CN 7000 2347 4486 5569 8483 11244 14507 400V/3/
    TAG 4553THR 4-1/2 R22 10.7 CN 7000 3058 5360 6635 9745 12467 15797 400V/3/
    TAG 4561THR 5 R22 112.5 CN 6600 3218 5954 7607 11447 14317 17813 400V/3/
    TAG 4568THR 6 R22 124.4 CN 6000 3320 6579 8566 12759 16221 20116 400V/3/
    TAG 4573THR 6-1/2 R22 134.8 CN 6000 4613 7033 8739 12634 15589 19298 400V/3/
    TAGD 4590THR 7-1/2 R22 180.4 CN 11500 4700 8309 10574 15628 19486 23990 400V/3/
    TAGD4610THR 9 R22 201.7 CN 11500 5103 9354 12058 17926 22340 27393 400V/3/
    TAGD 4612THR 10 R22 225 CN 11000 6604 11749 14841 22107 27561 34072 400V/3/
    TAGD4614THR 12 R22 269.6 CN 10500 7104 12055 15443 23590 29775 37160 400V/3/

     

    Performance data based on: 50Hz

    Ambient Temp: 32℃

     

    R134A MEDIUMHIGH BACK PRESSURE

     

    Compressor models Nominal Power (HP.)

    Refri-

    gerant

    Displa-

    cement

    (cm³)

    Expansion device

    Air Flow

    (m³/hr)

    Evaporating Temperature Voltage
    -25℃ -15℃ -10℃ 0℃ +7.2℃ +15℃
    AEZ 4430YHR 1/4 R134A 8.85 CN 410 162 311 393 604 778 982 208-220V/1/50HZ
    AEZ 3440YH 1/3 R134A 12.05 C 800 228 410 519 768 969 1212 220-240V/1/50HZ
    CAE 4440YHR 1/3 R134A 12.05 CN 800 228 410 519 768 969 1212 208-220V/1/50HZ
    AE 3440YH 1/3 R134A 12.05 C 800 241 433 553 841 1081 1375 220-240V/1/50HZ
    CAE 4440YHHR 1/3 R134A 12.05 CN 800 241 433 553 841 1081 1375 220-240V/1/50HZ
    CAE 4448YHR 3/7 R134A 14.15 CN 800 248 486 627 937 1186 1482 208-220V/1/50HZ
    CAE 4456YHR 7/16 R134A 16 CN 980 298 538 689 1034 1319 1669 208-220V/1/50HZ
    CAJ 4461YH/HR 1/2 R134A 18.3 CN 980 339 620 782 1156 1475 1843 208-220V/1/50HZ
    TAJ 4461YH/HR 1/2 R134A 18.3 CN 980 339 620 782 1156 1475 1843 400V/3/50HZ
    CAJ 4476YH/HR 5/8 R134A 21.75 CN 1130 447 750 956 1446 1867 2393 220-240V/1/50HZ
    CAJ 4492YH/HR 3/4 R134A 25.95 CN 980 494 925 1179 1742 2229 2776 208-220V/1/50HZ
    TAJ 4492YH/HR 3/4 R134A 25.95 CN 980 494 925 1179 1742 2229 2776 400V/3/50HZ
    CAJ 4511YH/HR 1 R134A 32.7 CN 980 803 1216 1478 2138 2687 3370 208-220V/1/50Hz
    TAJ 4511YH/HR 1 R134A 32.7 CN 980 803 1216 1478 2138 2687 3370 208-220V/1/50HZ
    FH 4518YH/HR 1-1/2 R134A 53.2 CN 2250 1163 1791 2250 3463 4488 5848 208-220V/1/50Hz
    TFH 4518YH/HR 1-1/2 R134A 53.2 CN 2250 1163 1791 2250 3463 4488 5848 400V/3/50HZ
    FH 4525YH/HR 2 R134A 74.25 CN 2250 1147 2128 2759 4154 5424 6945 208-220V/1/50HZ
    TFH 4525YH/HR 2 R134A 74.25 CN 2250 1147 2128 2759 4154 5424 6945 400V/3/50HZ
    TAG 4528YH 2-1/2 R134A 90.2 CN 3540 978 2302 3132 5062 6687 8697 400V/3/50HZ
    TAG 4534YHR 3 R134A 100.7 CN 4800 1336 2818 3760 5977 7859 10184 400V/3/50HZ
    TAG 4537YHR 3-1/4 R134A 112.5 CN 4500 1573 3258 4304 6698 8690 11133 400V/3/50HZ
    TAG 4543YHR 3-1/2 R134A 124.4 CN 4500 1737 3493 4638 7314 9601 12443 400V/3/50HZ

     

    Performance data based on: 50Hz

    Ambient Temp:32℃

     

    R404A MEDIUM/HIGH BACK PRESSURE COMPRESSORSR

     

    Compressor models Nominal Power (HP.)

    Refri-

    gerant

    Displ-

    acement

    (cm³)

    Expan-

    sion device

    Air Flow (m³/hr) Evaporating Temperature Voltage
    -25℃ -15℃ -10℃ 0℃ +7.2℃ +15℃
    AEZ 3440ZH 1/3 R404A 7.55 C 800   448 552 783 970 1049 208-220V/1/50HZ
    AEZ 4440ZHR 1/3 R404A 7.55 CN 800   448 552 783 970 1049 208-220V/1/50HZ
    AEZ 9440ZMHR 1/3 R404A 7.55 CN 800 262 448 552 783 970 1049 220-240V/1/50HZ
    CAE 9460ZMHR 1/2 R404A 11.3 CN 980 394 659 803 1117 1368 1472 208-220V/1/50HZ
    CAE 9470ZMHR 9/16 R404A 13.3 CN 1130 520 847 1030 1441 1775 1915 208-220V/1/50HZ
    CAJ 9480ZMH/HR 5/8 R404A 15.2 CN 1130 619 975 1176 1624 1992 2146 208-220V/1/50HZ
    TAJ 9480ZMH/HR 5/8 R404A 15.2 CN 1130 619 975 1176 1624 1992 2146 400V/3/50HZ
    CAJ 9510ZMHR 1 R404A 18.3 CN 980 773 1183 1427 1973 2398 2584 208-220V/1/50HZ
    TAJ 9510ZMHR 1 R404A 18.3 CN 980 773 1183 1427 1973 2398 2584 400V/3/50HZ
    CAJ 9513ZMHR 1-1/8 R404A 24.2 CN 980 861 1417 1718 2365 2869 3079 208-220V/1/50HZ
    TAJ 9513ZMHR 1-1/8 R404A 24.2 CN 980 861 1417 1718 2365 2869 3079 400V/3/50HZ
    CAJ4517ZHR 1-1/4 R404A 25.95 CN 2200   1757 2134 3029 3677 3960 208-220V/1/50HZ
    TAJ4517ZHR 1-1/4 R404A 25.95 CN 2200   1757 2134 3029 3677 3960 400V/3/50HZ
    CAJ 4519ZHR 1-3/4 R404A 34.45 CN 2250   2282 2731 3803 4643 5008 208-220V/1/50HZ
    TAJ 4519ZHR 1-3/4 R404A 34.45 CN 2250   2282 2731 3803 4643 5008 400V/3/50HZ
    FH 4522ZHR 2 R404A 40.8 CN 2250   2142 2664 3787 4676 5041 208-220V/1/50HZ
    TFH 4522ZHR 2 R404A 40.8 CN 2250   2142 2664 3787 4676 5041 400V/3/50HZ
    FH 4524ZHR 2 R404A 43.9 CN 2480   2397 2951 4160 5127 5529 208-220V/1/50HZ
    TFH 4524ZHR 2 R404A 43.9 CN 2480   2397 2951 4160 5127 5529 400V/3/50HZ
    FH 4531ZHRE 2-3/4 R404A 58.1 CN 4800   3416 4233 5990 7372 7939 208-220V/1/50HZ
    TFH 4531ZHR 2-3/4 R404A 58.1 CN 4800   3416 4233 5990 7372 7939 400V/3/50HZ
    FH 4540ZHR 3-1/2 R404A 74.25 CN 4800   4108 5016 7010 8609 9274 208-220V/1/50HZ
    TFH 4540ZHR 3-1/2 R404A 74.25 CN 4800   4108 5016 7010 8609 9274 400V/3/50HZ
    FHD 4548ZHR 4 R404A 87.8 CN 7000   4756 6237 9094 11059 11808 208-220V/1/50HZ
    TFHD 4548ZHR 4 R404A 87.8 CN 7000   4756 6237 9094 11059 11808 400V/3/50HZ
    FHD 4562ZHR 5 R404A 116.2 CN 6000   6673 8438 11749 13947 14767 208-220V/1/50HZ
    TFHD 4562ZHR 5 R404A 116.2 CN 6000   6673 8438 11749 13947 14767 400V/3/50HZ
    TAG 4546ZHR 4 R404A 90.2 CN 7000   4757 6013 8878 11256 12262 400V/3/50HZ
    TAG 4553ZHR 4-1/2 R404A 100.7 CN 7000   5085 6357 9338 11769 12815 400V/3/50HZ
    TAG 4561ZHR 5 R404A 112.5 CN 6600   5818 7351 10883 13766 14882 400V/3/50HZ
    TAG 4568ZHR 6 R404A 124.4 CN 6000   6631 8506 12540 15550 16790 400V/3/50HZ
    TAG 4573ZHR 6-1/2 R404A 134.8 CN 6000   7182 8881 12698 15853 17178 400V/3/50HZ
    TAGD 4590ZHR 7-1/2 R404A 180.4 CN 11500   8968 11266 16265 20237 21877 400V/3/50HZ
    TAGD 461OZHR 9 R404A 201.4 CN 11000   9796 12380 18172 22924 24918 400V/3/50HZ
    TAGD 4612ZHR 10 R404A 225 CN 11000   12015 14846 20947 25768 27754 400V/3/50HZ
    TAGD 4614ZHR 12 R404A 248.8 CN 10500   14074 17529 24416 29417 31386 400V/3/50HZ

     

    Performance data based on: 50Hz

    Ambient Temp: 32℃

     

    Tag4561Z 5HP Low Temperature Condensing Unit Suitable For Different Refrigerator Long Lifespan 0

    Tag4561Z 5HP Low Temperature Condensing Unit Suitable For Different Refrigerator Long Lifespan 1

     

    Contact Details
    Shanghai KUB Refrigeration Equipment Co., Ltd.

    Contact Person: Manager

    Send your inquiry directly to us (0 / 3000)

    Contact

    Address: No. 328 on the 4th plant hengyong Road, Jiading District, Shanghai

    Factory Address:No. 328 on the 4th plant hengyong Road, Jiading District, Shanghai