    Product Details:

    Place of Origin: Shanghai, China (Mainland)
    Brand Name: Tecumseh
    Certification: CE
    Model Number: TAG4561Z

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 Unit/Units
    Price: negotiable
    Packaging Details: Plywood pallet+carton
    Supply Ability: 50 units per month
    Contact Now
    Detailed Product Description
    Type: Condensing Unit Refrigerant: R404A/R507C
    Beand: Tecumseh Application: Cold Storage Room/Freezer Room/Chiller
    Voltage: 380V/3PH/50HZ Cooling Capacity: 3.75KW

    TAG4561Z 5HP COLD ROOM COMPRESSOR FRENCH TECUMSEH COMPRESSORS & CONDENSING UNITS SERIAL SPECIFICATION

     

    Feature:

     

    1. Tecumseh hermetic compressor

    2. With full range, air cooled & water cooled.

    3. All the accessories are world famous brand, which with reliable quality.

    4. Wide application, suitable for different refrigerant.

    5. Optional configuration is acceptable.

     

    R22 MEDIUM/HIH BACK PRESSURE

     

    Compressor models Nominal Power (HP.)

    Refrig-

    erant

    Displace-

    ment

    (cm³)

    Expansion device Air Flow (m³/hr) Evaporating Temperature Voltage  50HZ
    -25℃ -15℃ -10℃ 0℃ +7.2℃ +15℃
    CAJ 9480TMH/HR 5/8 R22 15.2 CN 1130 576 946 1155 1632 2036 2509 208-220V/1
    TAJ 9480TMH/HR 5/8 R22 15.2 CN 1130 576 946 1155 1632 2036 2509 400V/3
    CAJ 9510TMH/HR 1 R22 18.3 CN 980 711 1126 1374 1941 2411 2987 208-220V/1
    TAJ 9510TMH/HR 1 R22 18.3 CN 980 711 1126 1374 1941 2411 2987 400V/3

    CAJ9513TMH

    /HR

    1-1/8 R22 24.2 CN 980 806 1348 1666 2370 2899 3523 208-220V/1

    TAJ9513TMH

    /HR

    1-1/8 R22 24.2 CN 980 806 1348 1666 2370 2899 3523 400V/3
    CAJ 4517EHR 1-1/4 R22 25.95 CN 2200 1072 1692 2071 2978 3741 4681 208-220V/1
    TAJ 4517TH/HR 1-1/4 R22 25.95 CN 2200 1072 1692 2071 2978 3741 4681 400V/3/
    CAJ 4519TH/HR 1-3/4 R22 34.45 CN 2250 1250 2144 2642 3767 4669 5739 208-220V/1/
    TAJ 4519TH/HR 1-3/4 R22 34.45 CN 2250 1250 2144 2642 3767 4669 5739 400V/3/

    FH 4522FH

    /HR

    2 R22 40.8 CN 2250 1348 2257 2794 4028 5053 6297 208-220V/1/
    TFH 4522FH/HR 2 R22 40.8 CN 2250 1348 2257 2794 4028 5053 6297 400V/3/
    FH 4524FH/HR 2 R22 43.9 CN 2250 1282 2314 2910 4200 5322 6592 208-220V/1
    TFH 4524FH/HR 2 R22 43.9 ON 2250 1282 2314 2910 4200 5322 6592 400V/3/

    FH 4531FH

    /HR

    2-3/4 R22 58.1 CN 4800 1669 3611 4360 6163 7597 9277 208-220V/1
    TFH 4531FH/HR 2-3/4 R22 58.1 CN 4800 1669 3611 4360 6163 7597 9277 400V/3/
    TFH 4540FH/HR 3-1/2 R22 74.25 CN 4600 1890 4157 5137 7438 9194 11300 400V/3/
    TAG 4546THR 4 R22 90.2 CN 7000 2347 4486 5569 8483 11244 14507 400V/3/
    TAG 4553THR 4-1/2 R22 10.7 CN 7000 3058 5360 6635 9745 12467 15797 400V/3/
    TAG 4561THR 5 R22 112.5 CN 6600 3218 5954 7607 11447 14317 17813 400V/3/
    TAG 4568THR 6 R22 124.4 CN 6000 3320 6579 8566 12759 16221 20116 400V/3/
    TAG 4573THR 6-1/2 R22 134.8 CN 6000 4613 7033 8739 12634 15589 19298 400V/3/
    TAGD 4590THR 7-1/2 R22 180.4 CN 11500 4700 8309 10574 15628 19486 23990 400V/3/
    TAGD4610THR 9 R22 201.7 CN 11500 5103 9354 12058 17926 22340 27393 400V/3/
    TAGD 4612THR 10 R22 225 CN 11000 6604 11749 14841 22107 27561 34072 400V/3/
    TAGD4614THR 12 R22 269.6 CN 10500 7104 12055 15443 23590 29775 37160 400V/3/

     

    Performance data based on: 50Hz

    Ambient Temp: 32℃

     

    R134A MEDIUMHIGH BACK PRESSURE

     

    Compressor models Nominal Power (HP.)

    Refri-

    gerant

    Displa-

    cement

    (cm³)

    Expansion device

    Air Flow

    (m³/hr)

    Evaporating Temperature Voltage
    -25℃ -15℃ -10℃ 0℃ +7.2℃ +15℃
    AEZ 4430YHR 1/4 R134A 8.85 CN 410 162 311 393 604 778 982 208-220V/1/50HZ
    AEZ 3440YH 1/3 R134A 12.05 C 800 228 410 519 768 969 1212 220-240V/1/50HZ
    CAE 4440YHR 1/3 R134A 12.05 CN 800 228 410 519 768 969 1212 208-220V/1/50HZ
    AE 3440YH 1/3 R134A 12.05 C 800 241 433 553 841 1081 1375 220-240V/1/50HZ
    CAE 4440YHHR 1/3 R134A 12.05 CN 800 241 433 553 841 1081 1375 220-240V/1/50HZ
    CAE 4448YHR 3/7 R134A 14.15 CN 800 248 486 627 937 1186 1482 208-220V/1/50HZ
    CAE 4456YHR 7/16 R134A 16 CN 980 298 538 689 1034 1319 1669 208-220V/1/50HZ
    CAJ 4461YH/HR 1/2 R134A 18.3 CN 980 339 620 782 1156 1475 1843 208-220V/1/50HZ
    TAJ 4461YH/HR 1/2 R134A 18.3 CN 980 339 620 782 1156 1475 1843 400V/3/50HZ
    CAJ 4476YH/HR 5/8 R134A 21.75 CN 1130 447 750 956 1446 1867 2393 220-240V/1/50HZ
    CAJ 4492YH/HR 3/4 R134A 25.95 CN 980 494 925 1179 1742 2229 2776 208-220V/1/50HZ
    TAJ 4492YH/HR 3/4 R134A 25.95 CN 980 494 925 1179 1742 2229 2776 400V/3/50HZ
    CAJ 4511YH/HR 1 R134A 32.7 CN 980 803 1216 1478 2138 2687 3370 208-220V/1/50Hz
    TAJ 4511YH/HR 1 R134A 32.7 CN 980 803 1216 1478 2138 2687 3370 208-220V/1/50HZ
    FH 4518YH/HR 1-1/2 R134A 53.2 CN 2250 1163 1791 2250 3463 4488 5848 208-220V/1/50Hz
    TFH 4518YH/HR 1-1/2 R134A 53.2 CN 2250 1163 1791 2250 3463 4488 5848 400V/3/50HZ
    FH 4525YH/HR 2 R134A 74.25 CN 2250 1147 2128 2759 4154 5424 6945 208-220V/1/50HZ
    TFH 4525YH/HR 2 R134A 74.25 CN 2250 1147 2128 2759 4154 5424 6945 400V/3/50HZ
    TAG 4528YH 2-1/2 R134A 90.2 CN 3540 978 2302 3132 5062 6687 8697 400V/3/50HZ
    TAG 4534YHR 3 R134A 100.7 CN 4800 1336 2818 3760 5977 7859 10184 400V/3/50HZ
    TAG 4537YHR 3-1/4 R134A 112.5 CN 4500 1573 3258 4304 6698 8690 11133 400V/3/50HZ
    TAG 4543YHR 3-1/2 R134A 124.4 CN 4500 1737 3493 4638 7314 9601 12443 400V/3/50HZ

     

    Performance data based on: 50Hz

    Ambient Temp:32℃

     

    R404A MEDIUM/HIGH BACK PRESSURE COMPRESSORSR

     

    Compressor models Nominal Power (HP.)

    Refri-

    gerant

    Displ-

    acement

    (cm³)

    Expan-

    sion device

    Air Flow (m³/hr) Evaporating Temperature Voltage
    -25℃ -15℃ -10℃ 0℃ +7.2℃ +15℃
    AEZ 3440ZH 1/3 R404A 7.55 C 800   448 552 783 970 1049 208-220V/1/50HZ
    AEZ 4440ZHR 1/3 R404A 7.55 CN 800   448 552 783 970 1049 208-220V/1/50HZ
    AEZ 9440ZMHR 1/3 R404A 7.55 CN 800 262 448 552 783 970 1049 220-240V/1/50HZ
    CAE 9460ZMHR 1/2 R404A 11.3 CN 980 394 659 803 1117 1368 1472 208-220V/1/50HZ
    CAE 9470ZMHR 9/16 R404A 13.3 CN 1130 520 847 1030 1441 1775 1915 208-220V/1/50HZ
    CAJ 9480ZMH/HR 5/8 R404A 15.2 CN 1130 619 975 1176 1624 1992 2146 208-220V/1/50HZ
    TAJ 9480ZMH/HR 5/8 R404A 15.2 CN 1130 619 975 1176 1624 1992 2146 400V/3/50HZ
    CAJ 9510ZMHR 1 R404A 18.3 CN 980 773 1183 1427 1973 2398 2584 208-220V/1/50HZ
    TAJ 9510ZMHR 1 R404A 18.3 CN 980 773 1183 1427 1973 2398 2584 400V/3/50HZ
    CAJ 9513ZMHR 1-1/8 R404A 24.2 CN 980 861 1417 1718 2365 2869 3079 208-220V/1/50HZ
    TAJ 9513ZMHR 1-1/8 R404A 24.2 CN 980 861 1417 1718 2365 2869 3079 400V/3/50HZ
    CAJ4517ZHR 1-1/4 R404A 25.95 CN 2200   1757 2134 3029 3677 3960 208-220V/1/50HZ
    TAJ4517ZHR 1-1/4 R404A 25.95 CN 2200   1757 2134 3029 3677 3960 400V/3/50HZ
    CAJ 4519ZHR 1-3/4 R404A 34.45 CN 2250   2282 2731 3803 4643 5008 208-220V/1/50HZ
    TAJ 4519ZHR 1-3/4 R404A 34.45 CN 2250   2282 2731 3803 4643 5008 400V/3/50HZ
    FH 4522ZHR 2 R404A 40.8 CN 2250   2142 2664 3787 4676 5041 208-220V/1/50HZ
    TFH 4522ZHR 2 R404A 40.8 CN 2250   2142 2664 3787 4676 5041 400V/3/50HZ
    FH 4524ZHR 2 R404A 43.9 CN 2480   2397 2951 4160 5127 5529 208-220V/1/50HZ
    TFH 4524ZHR 2 R404A 43.9 CN 2480   2397 2951 4160 5127 5529 400V/3/50HZ
    FH 4531ZHRE 2-3/4 R404A 58.1 CN 4800   3416 4233 5990 7372 7939 208-220V/1/50HZ
    TFH 4531ZHR 2-3/4 R404A 58.1 CN 4800   3416 4233 5990 7372 7939 400V/3/50HZ
    FH 4540ZHR 3-1/2 R404A 74.25 CN 4800   4108 5016 7010 8609 9274 208-220V/1/50HZ
    TFH 4540ZHR 3-1/2 R404A 74.25 CN 4800   4108 5016 7010 8609 9274 400V/3/50HZ
    FHD 4548ZHR 4 R404A 87.8 CN 7000   4756 6237 9094 11059 11808 208-220V/1/50HZ
    TFHD 4548ZHR 4 R404A 87.8 CN 7000   4756 6237 9094 11059 11808 400V/3/50HZ
    FHD 4562ZHR 5 R404A 116.2 CN 6000   6673 8438 11749 13947 14767 208-220V/1/50HZ
    TFHD 4562ZHR 5 R404A 116.2 CN 6000   6673 8438 11749 13947 14767 400V/3/50HZ
    TAG 4546ZHR 4 R404A 90.2 CN 7000   4757 6013 8878 11256 12262 400V/3/50HZ
    TAG 4553ZHR 4-1/2 R404A 100.7 CN 7000   5085 6357 9338 11769 12815 400V/3/50HZ
    TAG 4561ZHR 5 R404A 112.5 CN 6600   5818 7351 10883 13766 14882 400V/3/50HZ
    TAG 4568ZHR 6 R404A 124.4 CN 6000   6631 8506 12540 15550 16790 400V/3/50HZ
    TAG 4573ZHR 6-1/2 R404A 134.8 CN 6000   7182 8881 12698 15853 17178 400V/3/50HZ
    TAGD 4590ZHR 7-1/2 R404A 180.4 CN 11500   8968 11266 16265 20237 21877 400V/3/50HZ
    TAGD 461OZHR 9 R404A 201.4 CN 11000   9796 12380 18172 22924 24918 400V/3/50HZ
    TAGD 4612ZHR 10 R404A 225 CN 11000   12015 14846 20947 25768 27754 400V/3/50HZ
    TAGD 4614ZHR 12 R404A 248.8 CN 10500   14074 17529 24416 29417 31386 400V/3/50HZ

     

    Performance data based on: 50Hz

    Ambient Temp: 32℃

     

    Tag4561Z 5HP Low Temperature Condensing Unit Suitable For Different Refrigerator Long Lifespan

    Tag4561Z 5HP Low Temperature Condensing Unit Suitable For Different Refrigerator Long Lifespan

     

    Contact Details
    Shanghai KUB Refrigeration Equipment Co., Ltd.

    Contact Person: Manager

    Send your inquiry directly to us (0 / 3000)

    Contact

    Address: No. 328 on the 4th plant hengyong Road, Jiading District, Shanghai

    Factory Address:No. 328 on the 4th plant hengyong Road, Jiading District, Shanghai