Maintenance methods for refrigeration units

November 16, 2024

Maintenance methods for refrigeration units

The compressor of the refrigeration unit is a crucial component in the unit, and the quality of the compressor directly affects the stability of the unit. Therefore, timely maintenance and upkeep of the refrigeration unit is necessary.

1. Replace lubricating oil

After long-term use, the lubricating oil quality of the refrigeration unit deteriorates, and impurities and moisture inside the oil increase, so it is necessary to regularly observe and check the oil quality. Once a problem is discovered, it should be replaced in a timely manner, and the lubricating oil brand replaced must comply with the technical specifications.

2. Replace the dry filter

The dry filter is an important component to ensure the normal circulation of refrigerant. Due to the immiscibility of water and refrigerant, if there is moisture in the system, it will greatly affect the operating efficiency of the unit. Therefore, it is very important to keep the internal system dry, and the filter element inside the drying filter must be replaced regularly.

3. Verification of safety valve

The condenser and evaporator on the chiller unit are both pressure vessels. According to regulations, a safety valve should be installed on the high-pressure end of the unit, that is, the condenser body. Once the unit is in an abnormal working environment, the safety valve can automatically release pressure to prevent high pressure from causing harm to the human body. So regular calibration of safety valves is very important for the safety of the entire unit.

4. Cleaning of condenser and evaporator

The cooling water of a water-cooled condenser is usually circulated through a cooling tower using tap water due to its open loop design. When the content of calcium and magnesium salts in water is high, they are easily decomposed and deposited on the cooling water pipes, forming scale and affecting heat transfer. Excessive scaling can also reduce the flow cross-section of cooling water, decrease the amount of water, and increase the condensation pressure. Therefore, when the quality of the cooling water used is poor, the cooling water pipes should be cleaned at least once a year to remove scale and other contaminants from the pipes.

5. Charging of refrigerant

Unless there are other special reasons, the unit generally does not produce a large amount of leakage. If a certain amount of refrigerant leaks due to improper use or after maintenance, it is necessary to add refrigerant again. Attention must be paid to the brand of refrigerant used in the unit when filling refrigerant.

Shanghai KUB Refrigeration Equipment Co., Ltd.

 

 

Free Call Video Chat

 

 

 

Address : No. 328 on the 4th plant hengyong Road, Jiading District, Shanghai
Factory Address : No. 328 on the 4th plant hengyong Road, Jiading District, Shanghai
Work Time : 8:30-17:30(Beijing time)
Phone :

86-021 -63184860-17(Work Time)

86--13916495206(Nonworking time)

Fax : 86-021-53750132
Email : lucy@shkubao.com

 

Customer Manager
Mr mick Cai
Phone : +86 13588563336
WhatsApp : +86 13588563336
Skype : kub.mick
WeChat : CP9301
Email : kub02@shkubao.com

 

Miss. Mophy Mao
Phone : +86 15001938306
WhatsApp : +86 15001938306
WeChat : kub-maomao
Email : kub@shhkubao.cn