All Products
Contact Person :
Amy lu
Phone Number :
+8613916495206
Whatsapp :
+8613916495206
20HP - 50HP Industrial Air Cooled Chiller For Extruder Blower Injection Moulding

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Details
Weight (KG) | 1500 | Voltage | 380V 50HZ |
---|---|---|---|
Refrigerant | R22/R404A | Application | Cold Room |
Color | White | Compressor | Vortex |
Highlight | Industrial Air Cooled Chiller,Extruder Air Cooled Chiller,20HP Air Cooled Condensing Unit |
Product Description
20HP to 50HP Industrial air cooled chiller for Extruder Blower Injection Moulding
Specifications and technical parameters of kub-47af air-cooled chiller (20 pieces) | |||
Serial number | name | Specification type | performance parameter |
1 | model | KUB-47AF | |
2 | Refrigerating capacity | 1Unit 1 kW | 47(evaporation temperature 0 ℃, condensation temperature 40 ℃) |
3 | Cold media | water | |
4 | cryogen | R22 | |
5 | Power Supply | V | 3N-380-50HZ |
6 | Overall power | KW | 15 |
7 | Matching cable | Power line 6 square meters | |
8 | Whole machine current | A | 33A |
9 | compressor | type | vortex |
10 | Cooling fan | type | External rotor axial flow fan |
11 | condenser | type | Aluminum fin sleeve copper tube type |
12 | Condensing motor power | KW | 3*0.6 |
13 | evaporator | type | Plate heat exchanger / water tank type |
15 | Water tank volume | rise | 250 |
16 | Make up port (DN) | 15 | 4branch |
17 | Chilled water inlet and outlet pipe (DN) | 50 | 2inch |
18 | Temperature digital display microcomputer controller | Display status | Full Chinese (English) display, real-time dynamic display |
19 | Pump power | KW | 1.2 |
20 | Pump head | rice | 20 |
21 | Chilled water flow | Cubic meter / hour | 12 |
22 | Alarm device | Abnormal temperature | Alarm and shut down the compressor |
23 | Protector | Reverse phase of power supply | The power phase detection prevents the compressor from reversing |
24 | Protector | safeguard | High and low voltage protection and antifreeze protection Overtemperature protection exhaust too high |
25 | Protector | overload protection | Thermal relay protection motor |
26 | Protector | Compressor overheating | The internal protector protects the compressor |
27 | Protector | short circuit | air switch |
28 | Overall dimension | Length * width * height (mm) | 1900*870*1550 |
29 | Machine weight | KG | 850 |
Specifications and technical parameters of kub-64af air-cooled chiller (25 pieces) | |||
Serial number | name | Specification type | performance parameter |
1 | model | KUB-64AF | |
2 | Refrigerating capacity | 1Unit 1 kW | 64(evaporation temperature 0 ℃, condensation temperature 40 ℃) |
3 | Cold media | water | |
4 | cryogen | R22 | |
5 | Power Supply | V | 3N-380-50HZ |
6 | Overall power | KW | 19 |
7 | Matching cable | Power line: 10m2 | |
8 | Whole machine current | A | 42A |
9 | compressor | type | vortex |
10 | Cooling fan | type | External rotor axial flow fan |
11 | condenser | type | Aluminum fin sleeve copper tube type |
12 | Condensing motor power | KW | 3*0.8 |
13 | evaporator | type | Plate heat exchanger / water tank type |
15 | Water tank volume | rise | 250 |
16 | Make up port (DN) | 15 | 4branch |
17 | Chilled water inlet and outlet pipe (DN) | 50 | 2inch |
18 | Temperature digital display microcomputer controller | Display status | Full Chinese (English) display, real-time dynamic display |
19 | Pump power | KW | 1.2 |
20 | Pump head | rice | 20 |
21 | Chilled water flow | Cubic meter / hour | 12 |
22 | Alarm device | Abnormal temperature | Alarm and shut down the compressor |
23 | Protector | Reverse phase of power supply | The power phase detection prevents the compressor from reversing |
24 | Protector | safeguard | High and low voltage protection and antifreeze protection Overtemperature protection exhaust too high |
25 | Protector | overload protection | Thermal relay protection motor |
26 | Protector | Compressor overheating | The internal protector protects the compressor |
27 | Protector | short circuit | air switch |
28 | Overall dimension | Length * width * height (mm) | 2700*1000*1850 |
29 | Machine weight | KG | 900 |
Specifications and technical parameters of kub-84af air-cooled chiller (30 pieces) | |||
Serial number | name | Specification type | performance parameter |
1 | model | KUB-84AF | |
2 | Refrigerating capacity | 1Unit 1 kW | 84(evaporation temperature 0 ℃, condensation temperature 40 ℃) |
3 | Cold media | water | |
4 | cryogen | R22 | |
5 | Power Supply | V | 3N-380-50HZ |
6 | Overall power | KW | 23 |
7 | Matching cable | Power line: 10m2 | |
8 | Whole machine current | A | 50A |
9 | compressor | type | vortex |
10 | Cooling fan | type | External rotor axial flow fan |
11 | condenser | type | Aluminum fin sleeve copper tube type |
12 | Condensing motor power | KW | 4*0.8 |
13 | evaporator | type | Plate heat exchanger / water tank type |
15 | Water tank volume | rise | 250 |
16 | Make up port (DN) | 15 | 4branch |
17 | Chilled water inlet and outlet pipe (DN) | 50 | 2inch |
18 | Temperature digital display microcomputer controller | Display status | Full Chinese (English) display, real-time dynamic display |
19 | Pump power | KW | 1.2 |
20 | Pump head | rice | 20 |
21 | Chilled water flow | Cubic meter / hour | 12 |
22 | Alarm device | Abnormal temperature | Alarm and shut down the compressor |
23 | Protector | Reverse phase of power supply | The power phase detection prevents the compressor from reversing |
24 | Protector | safeguard | High and low pressure protection antifreeze protection Overtemperature protection exhaust too high |
25 | Protector | overload protection | Thermal relay protection motor |
26 | Protector | Compressor overheating | The internal protector protects the compressor |
27 | Protector | short circuit | air switch |
28 | Overall dimension | Length * width * height (mm) | 3400*1000*1850 |
29 | Machine weight | KG | 980 |
Specifications and technical parameters of kub-108af air-cooled chiller (40 pieces) | |||
Serial number | name | Specification type | performance parameter |
1 | model | KUB-108AF | |
2 | Refrigerating capacity | 1Unit 1 kW | 108(evaporation temperature 0 ℃, condensation temperature 40 ℃) |
3 | Cold media | water | |
4 | cryogen | R22 | |
5 | Power Supply | V | 3N-380-50HZ |
6 | Overall power | KW | 30 |
7 | Matching cable | Power line: 10m2 | |
8 | Whole machine current | A | 66A |
9 | compressor | type | piston |
10 | Cooling fan | type | External rotor axial flow fan |
11 | condenser | type | Aluminum fin sleeve copper tube type |
12 | Condensing motor power | KW | 4*0.8 |
13 | evaporator | type | Plate heat exchanger / water tank type |
15 | Water tank volume | rise | /250 |
16 | Make up port (DN) | 15 | /4branch |
17 | Chilled water inlet and outlet pipe (DN) | 50 | 2inch |
18 | Temperature digital display microcomputer controller | Display status | Full Chinese (English) display, real-time dynamic display |
19 | Pump power | KW | 4 |
20 | Pump head | rice | 34 |
21 | Chilled water flow | Cubic meter / hour | 20 |
22 | Alarm device | Abnormal temperature | Alarm and shut down the compressor |
23 | Protector | Reverse phase of power supply | The power phase detection prevents the compressor from reversing |
24 | Protector | safeguard | High and low pressure protection antifreeze protection Overtemperature protection exhaust too high |
25 | Protector | overload protection | Thermal relay protection motor |
26 | Protector | Compressor overheating | The internal protector protects the compressor |
27 | Protector | short circuit | air switch |
28 | Overall dimension | Length * width * height (mm) | 3400*1000*1850 |
29 | Machine weight | KG | 1200 |
Specifications and technical parameters of kub-140af air-cooled chiller (50 pieces) | |||
Serial number | name | Specification type | performance parameter |
1 | model | KUB-140AF | |
2 | Refrigerating capacity | 1Unit 1 kW | 140(evaporation temperature 0 ℃, condensation temperature 40 ℃) |
3 | Cold media | water | |
4 | cryogen | R22 | |
5 | Power Supply | V | 3N-380-50HZ |
6 | Overall power | KW | 38 |
7 | Matching cable | Power line 16 square meters | |
8 | Whole machine current | A | 84A |
9 | compressor | type | piston |
10 | Cooling fan | type | External rotor axial flow fan |
11 | condenser | type | Aluminum fin sleeve copper tube type |
12 | Condensing motor power | KW | 5*0.8 |
13 | evaporator | type | Plate heat exchanger / water tank type |
15 | Water tank volume | rise | 400 |
16 | Make up port (DN) | 15 | 4branch |
17 | Chilled water inlet and outlet pipe (DN) | 50 | 2inch |
18 | Temperature digital display microcomputer controller | Display status | Full Chinese (English) display, real-time dynamic display |
19 | Pump power | KW | 3 |
20 | Pump head | rice | 25 |
21 | Chilled water flow | Cubic meter / hour | 32 |
22 | Alarm device | Abnormal temperature | Alarm and shut down the compressor |
23 | Protector | Reverse phase of power supply | The power phase detection prevents the compressor from reversing |
24 | Protector | safeguard | High and low pressure protection antifreeze protection Overtemperature protection exhaust too high |
25 | Protector | overload protection | Thermal relay protection motor |
26 | Protector | Compressor overheating | The internal protector protects the compressor |
27 | Protector | short circuit | air switch |
28 | Overall dimension | Length * width * height (mm) | 4000*1000*1850 |
29 | Machine weight | KG | 1800 |
Recommended Products