30HP Refrigeration Condensing Unit Air Cooled Multi Phase
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xVoltage | 380V/3Ph/50Hz | Warranty | 1 Year |
---|---|---|---|
After Warranty Service | Online Support | After-sales Service Provided | Online Support |
Highlight | 30HP Refrigeration Condensing Unit,Air Cooled Refrigeration Condensing Unit,Multi Phase Refrigeration Condensing Unit |
1. Produc t de sc ription
This HLG-H series products are applicable to the large size -5℃~8℃ and -15℃~-20℃ refrigeration system, as the large size fresh keeping cold rooms, ice making, chiller e tc.
This Series features Hanbell asymmetrical rotor screw compressors, multi -phase capacity regulation,
All this series products have a complete set protection devices for compressor motor coil, over discharging temperature, low oil level, low oil pressu re difference, high/low pressure etc.
3. Ma in c ompone nts
HLGS(F) ××M single unit:
●Screw Compressor. ●Condenser(only for Water cooled)●Receiver(only for Air cooled)●Filter vat ●Sight glasses ● Hydrojet syste m
●Feed pipe ball valve● Oil differential pressure protection● High & Low pressure protector ●Pressure gauge ●High pressure controller(control cooling tower or condenser fan)●Low pressure sensor(optional)●Unit control box (Nonshared control unit for screw compressor.)
HLGS(F) ××L single unit:
●Screw Compressor. ●Twice oil separ ate ●Oil separator outlet ball valve ●Oil return sight glasses ●Condenser(only for Water cooled)●Receiver(only for Air cooled)●Filter vat ●Sight glasses ●Hydrojet system ●Economizer system ●Oil differential pressur e protection ●High-low pressure protector. ●Pressure gauge ●High pressure controller(control cooling tower or condenser fan)●Low pressure sensor(optional)●Unit control box (Nonshared control unit for screw Compressor.)
HLGS(F) ××M Multi compressor rack :
●Screw Compressor. ●Oil separator ●Oil separ ator outlet valve ●Return oil system assembly ●Condenser(only for Water -cooling unit) ●Receiver ●Filter vat ●Sight glasses ●Hydrojet system ●Suction Filter ●Hi-glohw pressure protector ●Pressure gauge ●High
pressure controller (control cooling tower or con denser fan)●Low pressure sensor(optional)●Unit control box(PLC+Touch panel HLGS(F) ××L Multi compressor rack
●Screw Compressor ●Oil separator ●Oil separator outlet valve ●Return oil system assembly ●Oil cooler(only for Air -cooling unit)●Condenser(only for Water cooled)●Receiver ●Filter vat ●Sight glasses ●Hydrojet system ●Suction Filter ●Economizer system
●High-low pressure protector ●Pressure gauge ●High pressure controller (control condensing fan)●Low pressure
sensor(optional)●Unit control box (PLC+Touch panel) Air cooled rack condenser is optional.
Model | HLGF-30MH | HLGF-40MH | HLGF-50MH | HLGF-60MH | ||
Evaporating. Temperature( ℃) | -5℃~8℃ | |||||
Refrigerant | R22 | |||||
Power supply | 380V/50HZ | |||||
Comp. | Type | Semi-Hermetic Screw | ||||
Comp. Model | RC2 -100B | RC2 -140B | RC2 -180B | RC2 -230B | ||
Qty. | 66%-100% | 50%-75%-100% | ||||
Cap &Watt | Te 0℃ | Cap. (KW) | 73.3 | 99.9 | 131.1 | 174 |
Input (KW) | 25.0 | 32.9 | 41.2 | 55.1 | ||
Te -5℃ |
Cap. (KW) | 60.4 | 82.4 | 108.1 | 143.5 | |
Input (KW) | 23.9 | 31.5 | 39.5 | 52.7 | ||
Te -10℃ |
Cap. (KW) | 49.5 | 67.5 | 88.5 | 117.5 | |
Input (KW) | 22.9 | 30.2 | 37.8 | 50.5 | ||
Connect | Liquid dia.. (mm) | φ54 | φ54 | φ66 | φ76 | |
Gas out dia.. (mm) | φ22 | φ28 | φ28 | φ42 | ||
Discharge (mm) | φ42 | φ42 | φ42 | φ54 | ||
Liquid in(mm) | φ26 | φ35 | φ35 | φ35 | ||
Overall Size |
A(mm) | 1700 | 1700 | 2150 | 2300 | |
B(mm) | 670 | 670 | 680 | 770 | ||
C(mm) | 1100 | 1100 | 1100 | 1250 | ||
overall size a×b (mm) | 1000×390 | 1000×390 | 1200×390 | 1200×390 |
Model | HLGF-70MH | HLGF-80MH | HLGF-90MH | HLGF-100MH | ||
Evaporating. Temperature( ℃) | -5℃~8℃ | |||||
Refrigerant | R22 | |||||
Power supply | 380V/50HZ | |||||
Co mp. | Type | Semi-Hermetic Screw | ||||
Comp. Model | RC2 -260B | RC2 -310B | RC2 -340B | RC2 -370B | ||
Qty. | 50%-75%-100% | |||||
Cap &Watt | Te 0℃ | Cap. (KW) | 190.9 | 237.7 | 260.1 | 281.6 |
Input (KW) | 60.0 | 71.0 | 78.2 | 85.3 | ||
Te -5℃ |
Cap. (KW) | 157.5 | 196.1 | 214.6 | 232.3 | |
Input (KW) | 57.5 | 68.0 | 74.9 | 81.7 | ||
Te -10℃ |
Cap. (KW) | 129.0 | 160.6 | 171.7 | 190.2 | |
Input (KW) | 55.0 | 65.2 | 71.8 | 78.3 | ||
Connect | Liquid dia.. (mm) | φ76 | φ76 | φ108 | φ108 | |
Gas out dia.. (mm) | φ42 | φ42 | φ42 | φ42 | ||
Discharge (mm) | φ54 | φ54 | φ66 | φ66 | ||
Liquid in (mm) | φ35 | φ54 | φ54 | φ54 | ||
Overall Size | A(mm) | 2300 | 2600 | 2600 | 2600 | |
B(mm) | 770 | 850 | 850 | 850 | ||
C(mm) | 1250 | 1300 | 1300 | 1300 | ||
overall size a×b(mm) | 1200×450 | 1200×450 | 1500×500 | 1500×500 |
Remark :Cooling capacity and input power under condensing temp. at 45 ℃
Model | HLGF2-60MH | HLGF2-80MH | HLGF2-100MH | HLGF2-120MH | ||
Evaporating. Temperature( ℃) | -5℃~8℃ | |||||
Refrigerant | R22 | |||||
Power supply | 380V/50HZ | |||||
Comp. | Type | Semi-Hermetic Screw | ||||
Comp. Model | RC2 -100B | RC2 -140B | RC2 -180B | RC2 -230B | ||
Qty. | 2 | 2 | 2 | 2 | ||
Energy adjustment | 33%-50%-66%-100% | 25%-50%-75%-100% | ||||
Cap .& Input | Te 0℃ | Cap. (KW) | 146.6 | 199.8 | 262.2 | 348 |
Input (KW) | 50.0 | 65.8 | 82.4 | 100.2 | ||
Te -5℃ |
Cap. (KW) | 120.8 | 164.8 | 216.2 | 287 | |
Input (KW) | 47.8 | 63.0 | 79.0 | 105.4 | ||
Te -10℃ |
Cap. (KW) | 99 | 135 | 183.6 | 235 | |
Input (KW) | 45.8 | 60.4 | 75.6 | 101.0 | ||
Connector | Liquid dia.. (mm) | φ76 | φ76 | φ108 | φ108 | |
Gas out dia.. (mm) | φ42 | φ42 | φ54 | φ54 | ||
Discharge (mm) | φ42 | φ42 | φ76 | φ76 | ||
Liquid in (mm) | φ35 | φ35 | φ42 | φ42 | ||
Overall SizeA×B×C(mm) | 2300×1500×1460 | 2300×1500×1460 | 2650×1650×1470 | 3090×1850×1860 |
Model | HLGF2-140MH | HLGF2-160MH | HLGF2-180MH | HLGF2-200MH | ||
Evaporating. Temperature( ℃) | -5℃~8℃ | |||||
Refrigerant | R22 | |||||
Power supply | 380V/50HZ | |||||
Comp. | Type | Semi-Hermetic Screw | ||||
Comp. Model | RC2 -260B | RC2 -310B | RC2 -340B | RC2 -370B | ||
Qty. | 2 | 2 | 2 | 2 | ||
Energy Saving | 25%-50%-75%-100% | |||||
Cap. & Input | Te 0℃ | Cap. (KW) | 381.8 | 475.4 | 520.2 | 563.2 |
Input (KW) | 120.0 | 142.0 | 156.4 | 170.6 | ||
Te -5℃ |
Cap. (KW) | 315 | 392.2 | 429.2 | 464.6 | |
Input (KW) | 115.0 | 136.0 | 149.8 | 163.4 | ||
Te -10℃ |
Cap. (KW) | 258 | 321.2 | 351.4 | 380.4 | |
Input (KW) | 110.0 | 130.4 | 143.6 | 156.6 | ||
Connector | Liquid dia.. (mm) | φ108 | φ108 | φ108 | φ133 | |
Gas out dia.. (mm) | φ54 | φ54 | φ54 | φ54 | ||
Discharge (mm) | φ76 | φ76 | φ76 | φ108 | ||
Liquid in (mm) | φ54 | φ54 | φ54 | φ66 | ||
Overall Size A×B×C(mm) | 3290×1850×1860 | 3370×2050×1860 | 3370×2050×1860 | 3470×2100×2100 |
Model | HLGF3-90MH | HLGF3-120MH | HLGF3-150MH | HLGF3-180MH | ||
Evaporating. Temperature( ℃) | -5℃~8℃ | |||||
Refrigerant | R22 | |||||
Power supply | 380V/50HZ | |||||
Comp. | Type | Semi-Hermetic Screw | ||||
Comp. Model | RC2 -100B | RC2 -140B | RC2 -180B | RC2 -230B | ||
Qty. | 3 | 3 | 3 | 3 | ||
Energy Saving | 33%-66%-100% | 16%-33%-50%-66%-83% -100% |
||||
Cap. & Input | Te 0℃ | Cap. (KW) | 219.9 | 299.7 | 393.3 | 522 |
Input (KW) | 75.0 | 98.7 | 123.6 | 165.3 | ||
Te -5℃ |
Cap. (KW) | 181.2 | 247.2 | 324.3 | 430.5 | |
Input (KW) | 71.7 | 94.5 | 118.5 | 158.1 | ||
Te -10℃ |
Cap. (KW) | 148.2 | 202.5 | 265.5 | 352.5 | |
Input (KW) | 68.7 | 90.6 | 113.4 | 151.5 | ||
Connector | Liquid dia.. (mm) | 2×φ76 | 2×φ76 | 2×φ76 | 2×φ108 | |
Gas out dia. (mm) | φ35 | φ42 | φ54 | φ54 | ||
Discharge (mm) | φ42 | φ76 | φ76 | φ76 | ||
Liquid in (mm) | φ42 | φ54 | φ54 | φ66 | ||
Overall Size A×B×C(mm) | 2800×1500×1470 | 3000×1600×1780 | 3200×1700×1790 | 3700×1900×1860 |
Model | HLGF3-210MH | HLGF3-240MH | HLGF3-270MH | HLGF3-300MH | ||
Evaporating. Temperature( ℃) | -5℃~8℃ | |||||
Refrigerant | R22 | |||||
Power supply | 380V/50HZ | |||||
Comp. | Type | Semi-Hermetic Screw | ||||
Comp. Model | RC2 -260B | RC2 -310B | RC2 -340B | RC2 -370B | ||
Qty. | 3 | 3 | 3 | 3 | ||
Energy Saving | 16%-33%-50%-66%-83%-100% | |||||
Cap. & Input | Te 0℃ | Cap. (KW) | 572.7 | 713.1 | 780.3 | 844.8 |
Input (KW) | 180.0 | 213.0 | 234.6 | 255.9 | ||
Te -5℃ |
Cap. (KW) | 472.5 | 583.3 | 643.8 | 696.9 | |
Input (KW) | 172.5 | 204.0 | 224.7 | 245.1 | ||
Te -10℃ |
Cap. (KW) | 387 | 481.8 | 527.1 | 570.6 | |
Input (KW) | 165.0 | 195.6 | 215.4 | 234.9 | ||
Connector | Liquid dia.. (mm) | 2×φ108 | 2×φ108 | 2×φ108 | 2×φ108 | |
Gas out dia.. (mm) | φ54 | φ66 | φ66 | φ66 | ||
Discharge (mm) | φ108 | φ108 | φ108 | φ108 | ||
Liquid in (mm) | φ66 | φ66 | φ66 | φ66 | ||
Overall Size A×B×C(mm) | 3930×2050×2100 | 3930×2040×2100 | 3930×2140×2100 | 3930×2140×2100 |
Remark :Cooling capacity and input power under condensing temp. at 45 ℃
Model | HLGF-30LH | HLGF-40LH | HLGF-50LH | HLGF-60LH | ||||
Evaporating. Temperature( ℃) | -15~-20 | |||||||
Refrigerant | R22 | |||||||
Power supply | 380V/50HZ | |||||||
Comp. | Type | Semi-Hermetic Screw | ||||||
Comp. Model | RC2 -100B | RC2 -140B | RC2 -180B | RC2 -230B | ||||
Qty. | 66%-100% | 50%-75%-100% | ||||||
Cap &Watt | Te -20℃ |
Cap. (KW) | 41.2 | 56.2 | 73.8 | 97.9 | ||
Input (KW) | 23.8 | 31.4 | 39.4 | 52.5 | ||||
Te -25℃ |
Cap. (KW) | 33.7 | 45.9 | 60.2 | 79.9 | |||
Input (KW) | 23.1 | 30.4 | 38.1 | 50.9 | ||||
Te -30℃ |
Cap. (KW) | 27.2 | 37 | 48.6 | 64.5 | |||
Input (KW) | 21.5 | 28.7 | 36.8 | 49.1 | ||||
Connect | Liquid dia.. (mm) | φ54 | φ54 | φ66 | φ76 | |||
Gas out dia.. (mm) | φ22 | φ22 | φ28 | φ28 | ||||
Discharge (mm) | φ42 | φ42 | φ42 | φ54 | ||||
Liquid in (mm) | φ28 | φ35 | φ35 | φ35 | ||||
Overall Size | A (mm) | 1700 | 1700 | 2150 | 2300 | |||
B(mm) | 670 | 670 | 680 | 770 | ||||
C(mm) | 1140 | 1140 | 1150 | 1300 | ||||
overall size a×b (mm) | 1000×390 | 1000×390 | 1200×390 | 1200×450 |
Model | HLGF-70LH | HLGF-80LH | HLGF-90LH | HLGF-100LH | ||||
Evaporating. Temperature( ℃) | -15~-20 | |||||||
Refrigerant | R22 | |||||||
Power supply | 380V/50HZ | |||||||
Comp. | Type | Semi-Hermetic Screw | ||||||
Comp. Model | RC2 -260B | RC2 -310B | RC2 -340B | RC2 -370B | ||||
50%-75%-100% | ||||||||
Cap &Watt | Te -20℃ |
Cap. (KW) | 107.5 | 133.8 | 146.4 | 158.5 | ||
Input (KW) | 51.6 | 67.8 | 74.6 | 81.4 | ||||
Te -25℃ |
Cap. (KW) | 87.7 | 109.2 | 119.5 | 129.3 | |||
Input (KW) | 55.4 | 65.6 | 72.2 | 78.8 | ||||
Te -30℃ |
Cap. (KW) | 70.8 | 88.1 | 96.4 | 104.3 | |||
Input (KW) | 44.5 | 52.8 | 58.1 | 63.4 | ||||
Connect | Liquid dia.. (mm) | φ76 | φ76 | φ108 | φ108 | |||
Gas out dia.. (mm) | φ28 | φ35 | φ42 | φ42 | ||||
Discharge (mm) | φ54 | φ54 | φ66 | φ66 | ||||
Liquid in (mm) | φ35 | φ42 | φ42 | φ42 | ||||
Overall Size | A(mm) | 2300 | 2600 | 2600 | 2600 | |||
B(mm) | 770 | 850 | 850 | 850 | ||||
C(mm) | 1300 | 1350 | 1350 | 1300 | ||||
overall size a×b(mm) | 1200×450 | 1500×500 | 1500×500 | 1500×500 |
Remark :Cooling capacity and input power under condensing temp. at 45 ℃
Model | HLGF2-60LH | HLGF2-80LH | HLGF2-100LH | HLGF2-120LH | |||
Evaporating. Temperature( ℃) | -15℃~-20℃ | ||||||
Refrigerant | R22 | ||||||
Power supply | 380V/50HZ | ||||||
Comp. | Type | Semi-Hermetic Screw | |||||
Comp. Model | RC2 -100B | RC2 -140B | RC2 -180B | RC2 -230B | |||
Qty. | 2 | 2 | 2 | 2 | |||
Energy Saving | 33%-50%-66%-100% | 25%-50%-75%-100% | |||||
Cap.& Input | Te -20℃ |
Cap. (KW) | 82.4 | 112.4 | 147.6 | 195.8 | |
Input (KW) | 47.6 | 62.8 | 78.8 | 105.0 | |||
Te -25℃ |
Cap. (KW) | 67.4 | 91.8 | 120.4 | 159.8 | ||
Input (KW) | 46.2 | 60.8 | 76.2 | 101.8 | |||
Te -30℃ |
Cap. (KW) | 54.4 | 74 | 97.2 | 129 | ||
Input (KW) | 43.0 | 57.4 | 73.6 | 98.2 | |||
Connector | Liquid dia.. (mm) | φ76 | φ76 | φ108 | φ108 | ||
Gas out dia.. (mm) | φ35 | φ35 | φ42 | φ42 | |||
Discharge (mm) | φ54 | φ54 | φ76 | φ76 | |||
Liquid in (mm) | φ42 | φ44 | φ54 | φ54 | |||
Overall Size A×B×C(mm) | 2300×1500×1460 | 2300×1500×1460 | 2650×1650×1470 | 3090×1850×1860 |
Model | HLGF2-140LH | HLGF2-160LH | HLGF2-180LH | HLGF2-200LH | |||
Evaporating. Temperature( ℃) | -15℃~-20℃ | ||||||
Refrigerant | R22 | ||||||
Power supply | 380V/50HZ | ||||||
Comp. | Type | Semi-Hermetic Screw | |||||
Comp. Model | RC2 -260B | RC2 -310B | RC2 -340B | RC2 -370B | |||
Qty. | 2 | 2 | 2 | 2 | |||
Energy Saving | 25%-50%-75%-100% | ||||||
Cap. & Input | Te -20℃ |
Cap. (KW) | 215 | 267.6 | 292.8 | 317 | |
Input (KW) | 103.2 | 135.6 | 149.2 | 162.8 | |||
Te -25℃ |
Cap. (KW) | 175.4 | 218.4 | 239 | 258.6 | ||
Input (KW) | 110.8 | 131.2 | 144.4 | 152 | |||
Te -30℃ |
Cap. (KW) | 141.6 | 176.2 | 192.8 | 195.2 | ||
Input (KW) | 107.0 | 126.6 | 139.4 | 152.0 | |||
Connector | Liquid dia.. (mm) | φ108 | φ108 | φ108 | φ133 | ||
Gas out dia.. (mm) | φ42 | φ54 | φ54 | φ54 | |||
Discharge (mm) | φ76 | φ76 | φ76 | φ108 | |||
Liquid in (mm) | φ54 | φ54 | φ54 | φ66 | |||
Overall Size A×B×C(mm) | 3290×1850×1860 | 3370×2010×1860 | 3370×2010×1860 | 3470×2100×2100 |
Model | HLGF3-90LH | HLGF3-120LH | HLGF3-150LH | HLGF3-180LH | ||||
Evaporating. Temperature( ℃) | -15℃~-20℃ | |||||||
Refrigerant | R22 | |||||||
Power supply | 380V/50HZ | |||||||
Comp. | Type | Semi-Hermetic Screw | ||||||
Comp. Model | RC2 -100B | RC2 -140B | RC2 -180B | RC2 -230B | ||||
Qty. | 3 | 3 | 3 | 3 | ||||
Energy Saving | 33%-66%-100% | 16%-33%-50%-66%-83 %-100% |
||||||
Cap. & Input | Te -20℃ |
Cap. (KW) | 123.6 | 168.6 | 211.4 | 293.7 | ||
Input (KW) | 71.4 | 94.2 | 118.2 | 157.5 | ||||
Te -25℃ |
Cap. (KW) | 101.1 | 137.7 | 180.6 | 239.7 | |||
Input (KW) | 69.3 | 91.2 | 114.3 | 152.7 | ||||
Te -30℃ |
Cap. (KW) | 81.6 | 111 | 145.8 | 193.5 | |||
Input (KW) | 64.5 | 86.1 | 110.4 | 147.3 | ||||
Connector | Liquid dia.. (mm) | 2×φ66 | 2×φ76 | 2×φ76 | 2×φ108 | |||
Gas out dia.. (mm) | φ35 | φ42 | φ54 | φ54 | ||||
Discharge (mm) | φ54 | φ76 | φ89 | φ76 | ||||
Liquid in (mm) | φ42 | φ42 | φ42 | φ54 | ||||
Overall Size A×B×C(mm) | 2800×1570×1460 | 3000×1630×1780 | 3200×1690×1790 | 3700×1910×1860 |
Model | HLGF3-210LH | HLGF3-240LH | HLGF3-270LH | HLGF3-300LH | ||||
Evaporating. Temperature( ℃) | -15℃~-20℃ | |||||||
Refrigerant | R22 | |||||||
Power supply | 380V/50HZ | |||||||
Comp. | Type | Semi-Hermetic Screw | ||||||
Comp. Model | RC2 -260B | RC2 -310B | RC2 -340B | RC2 -370B | ||||
Qty. | 3 | 3 | 3 | 3 | ||||
Energy Saving | 16%-33%-50%-66%-83%-100% | |||||||
Cap. & Input | Te -20℃ |
Cap. (KW) | 322.5 | 401.4 | 439.2 | 475.5 | ||
Input (KW) | 154.8 | 203.4 | 223.8 | 244.2 | ||||
Te -25℃ |
Cap. (KW) | 263.1 | 327.6 | 358.5 | 387.9 | |||
Input (KW) | 166.2 | 196.8 | 216.6 | 236.4 | ||||
Te -30℃ |
Cap. (KW) | 212.4 | 264.3 | 289.2 | 312.9 | |||
Input (KW) | 160.5 | 189.9 | 209.1 | 228.0 | ||||
Connect or | Liquid dia.. (mm) | 2×φ108 | 2×φ108 | 2×φ108 | 2×φ108 | |||
Gas out dia.. (mm) | φ54 | φ54 | φ54 | φ54 | ||||
Discharge (mm) | φ108 | φ108 | φ108 | φ108 | ||||
Liquid in (mm) | φ54 | φ66 | φ66 | φ66 | ||||
Overall Size A×B×C(mm) | 3930×2040×2100 | 3930×2040×2100 | 3930×2140×2100 | 3930×2140×2100 |