Black Refrigeration Condensing Unit TAJ4519 LTAJ4519EHR

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xType | COMPRESSOR | Compressor | 2HP |
---|---|---|---|
Place Of Origin | Shanghai, China | Certification | Ce |
Warranty | 1 Year | Video Outgoing-inspection | Not Available |
Key Words | Refrigeration Unit | Voltage | 380V/3Ph/50Hz |
Brand | KUB | Packing | Wooden Case |
Condenser | Air Cooled Condenser | MOQ | 1 |
Supply Ability | 1000 Set/Sets Per Year | ||
Highlight | Black Refrigeration Condensing Unit,Refrigeration Condensing Unit TAJ4519,LTAJ4519EHR Refrigeration Condensing Unit |
Product descriptions from the supplier
OLTL200T Monoblock condensing unit 2hp cold room condensing unit
Model | Type | Specifications | Condensation temperature ( ℃) |
Evaporation temperature ( ℃) | |||||
-23 | -18 | -12 | -6 | ||||||
OLTL100T | Roof-top Side insert |
Compressor | 1HP | Cooling capacity (Watt) |
37.8 | 1368 | 1791 | 2368 | 3031 |
Voltage | 380V/3/50 | 43.3 | 1565 | 2112 | 2665 | 3444 | |||
Condensation Air volume |
1650m³/h | 48.9 | 1337 | 1827 | 2368 | 3043 | |||
Evaporating Air volume |
1650m³/h | Input power (Watt) |
37.3 | 852 | 959 | 1067 | 1161 | ||
Motor Power | 0.22kw | 43.3 | 965 | 1080 | 1193 | 1269 | |||
48.9 | 972 | 1094 | 1224 | 1323 | |||||
OLTL200T | Roof-top Side insert |
Compressor | 2HP | Cooling capacity (Watt) |
30 | 2300 | 2900 | 3500 | 5200 |
Voltage | 380V/3/50 | 40 | 1900 | 2400 | 3000 | 4400 | |||
Condensation Air volume |
2600m³/h | 50 | - | 1800 | 2400 | 3600 | |||
Evaporating Air volume |
2600m³/h | Input power (Watt) |
30 | 1214 | 1232 | 1210 | 1209 | ||
Motor Power | 0.27Kw | 40 | 1624 | 1602 | 1621 | 1536 | |||
50 | - | 2106 | 2040 | 1917 | |||||
OLTL300T | Roof-top Side insert |
Compressor | 3HP | Cooling capacity(Watt) | 30 | 3200 | 4000 | 4900 | 7100 |
Voltage | 380V/3/50 | 40 | 2800 | 3500 | 4300 | 6200 | |||
Condensation Air volume |
5500m³/h | 50 | - | 2900 | 3500 | 5100 | |||
Evaporating Air volume |
5500m³/h | Input power (Watt) |
30 | 1618 | 1642 | 1613 | 1612 | ||
Motor Power | 0.85Kw | 40 | 2079 | 2051 | 2075 | 1966 | |||
50 | - | 2527 | 2448 | 2300 | |||||
OLTL400T | Side insert | Compressor | 4HP | Cooling capacity (Watt) |
30 | 4900 | 6000 | 7300 | 10700 |
Voltage | 380V/3/50 | 40 | 4200 | 5300 | 6400 | 9300 | |||
Condensation Air volume |
5500m³/h | 50 | - | 4300 | 5300 | 7700 | |||
Evaporating Air volume |
5500m³/h | Input power (Watt) |
30 | 2346 | 2381 | 2339 | 2337 | ||
Motor Power | 0.85Kw | 40 | 3014 | 2973 | 3009 | 2851 | |||
50 | - | 3740 | 3623 | 3405 | |||||
OLTL500T | Side insert | Compressor | 5HP | Cooling capacity (Watt) |
30 | 5800 | 7200 | 8800 | 12800 |
Voltage | 380V/3/50 | 40 | 5000 | 6200 | 7600 | 11100 | |||
Condensation Air volume |
5500m³/h | 50 | - | 5100 | 6300 | 9200 | |||
Evaporating Air volume |
5500m³/h | Input power (Watt) |
30 | 2810 | 2813 | 2841 | 2908 | ||
Motor Power | 0.85Kw | 40 | 3609 | 3521 | 3523 | 3612 | |||
50 | - | 4509 | 4436 | 4462 | |||||
Temperature |
Volume | Storage capacity |
Horsepower | Model | Temperature | volume | Storage capacity |
Horsepower | Moodel |
m³ | Ton | HP | OLT | m³ | Ton | HP | OLT | ||
5-0℃ | 4-10 | 1-2 | 1 | 100Z | -15--18℃ | 3-5 | 0-1 | 1 | 100L |
10-22 | 2-4 | 2 | 200Z | 5-12 | 1-3 | 2 | 200L | ||
22-33 | 4-7 | 3 | 300Z | 12-20 | 3-5 | 3 | 300L | ||
33-45 | 7-10 | 4 | 400Z | 20-30 | 5-7 | 4 | 400L | ||
46-60 | 11-15 | 5 | 500Z | 30-42 | 7-10 | 5 | 500L |
Lead time
Quantity (sets) | 1 - 1 | 2 - 10 | > 10 |
Lead time (days) | 20 | 25 | To be negotiated |
Selection Principles
1. Compressor capacity should be determined according to each evaporating temperature mechanical load multiplied by the total system operating time factor. In addition to special requirements, generally do not use the machine equipment.
Reciprocating piston compressors Freon
2. Selection, when the compression ratio is greater than 10 should be the two-stage compressor; Should be less than or equal to 10 single stage compression. Freon two-stage compression system generally should adopt a throttle in the middle of incomplete cooling.
3. Generally cold in some of the cooler, oil separators, condensers, liquid and other equipment should be with Freon refrigeration compressor cooling capacity to adapt.
4. Selection of Freon refrigeration compressors working conditions, working conditions shall not exceed the limit specified in Shenzhen cold storage companies.
5. Freon refrigeration cooling systems, heat recovery should be used in general circulation.
6. Refrigeration compressor operating hours, for 5 ~ 100t of cold, generally can be every day and night operation 12 ~ 16h.