Compact Semi Hermetic Parallel Rack Refrigeration BBS Series

Place of Origin Shanghai, China
Brand Name KUB
Certification CE
Model Number Describe
Minimum Order Quantity 1
Price Consult
Packaging Details Pallet packaging
Delivery Time 20days
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 1000 Piece/Pieces per Year

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Type Compressor After-sales Service Provided Engineers Available To Service Machinery Overseas
Refrigerant R404a Cooling Capacity From 1800W To 95600W
Voltage 380V/3Ph/50Hz Application Cold Storage Room Freezer Room
High Light

Semi Hermetic Parallel Rack Refrigeration

,

Compact Parallel Rack Refrigeration

,

R404a Parallel Rack Refrigeration

Leave a Message
Product Description

BBS Series Semi Hermetic Compressor Racks Parallel Refrigeration Equipment

 

1. Produc t de sc ription
◆ With bizter ECOLINE series semi-hermetic compressor
◆ Multi compressors were parallel connected to provide bigger capacity sharing same discharge pipe,suction pipe, condenser,
liquid receiver etc.
◆ Compact design for easy installation and small installation size.
◆ Multi stage energy adjustments according to cooling capacity to save operation cost.

 

Compact Semi Hermetic Parallel Rack Refrigeration BBS Series 0

 

 

3. Ma in c ompone nts
●Compressor
●Crankcase heater
●vibration eliminator
●Oil separator
●Oil balance system
●Oil filter
●Receiver
●Drier & Filter
●Sight glasses
●Gas separator
●Suction filter
●Pressure controller
●Pressure gauge
●Oil protector (with oil pump)
●Cylinder fan(Low temp. Unit)
●Electric control
Air-cooling Conde nser or evaporating. Condenser is optional!
For water cooled unit :
●Compressor
●Crankcase heater
●vibration eliminator
●Oil separator
●Oil balance system
●Oil filter
●Water condenser
●Drier & Filter
●Sight glasses
●Gas separator
●Pressure controller
●Presure gauge
●Oil protector (with oil pump)
●Cylinder fan (Low temp. Unit)
●Electric control
Remark :
The compressor rack controller is employed as standard components. PLC controller is optional.

 

4.2 Water cooled Rack
4.2.1 Medium Temp. (Te -5~-20℃)
4.2.1.1 Refrigerant R22
4.2.1.1.1Water cooled Mid Temp 2 compressor racks

Model BBS2-
20MB 30MB 40MB 50MB 60MB 70MB 80MB 100MB
Temperature( ℃) -5℃~5℃
Refrigerant R22
Power supply 380V/50HZ
Comp. Type Semi-hermetic
Comp. Model 4VES-10 4PES-15 4NES-20 4HE-25 4GE -30 6HE-35 6GE -40 6FE-50
Qty 2 2 2 2 2 2 2 2
Condenser Type Shell & Tube
Cooling Water (m3/h) 13 18 20.6 28 32 38 48 58
Connector Size 2-1/2″ 2-1/2″ 2-1/2″ 2-1/2″ 3″ 3″ 3″ 4″
Cap. & Watt Te
-5℃
Cap (W) 44600 61800 72800 96800 112200 145400 166800 200800
Input (KW) 13.62 18.98 22.24 29.78 34.28 44.8 51.4 62.6
Te
-10℃
Cap (W) 35860 49600 58600 78200 90800 117200 134600 162200
Input (KW) 12.66 17.58 20.68 27.76 32.02 41.8 48.0 58.4
Te
-15℃
Cap (W) 28360 39080 46400 62200 72400 93200 107000 129200
Input (KW) 11.56 16.0 18.9 25.46 29.42 38.24 44.0 53.8
Conne
ctor
Liquid outlet Connect(mm) φ42 φ54 φ54 φ66 φ66 φ76 φ76 φ76
Gas Connect (mm) φ22 φ22 φ28 φ28 φ28 φ35 φ35 φ35
Overall Size L(mm) 2300 2300 2300 2300 2300 2300 2300 2300
W(mm) 1250 1250 1250 1250 1250 1250 1250 1250
H(mm) 1850 1850 1850 1850 1850 1850 1850 1850

Above cooling capacity and input power under condition of condensing Temp. 40 ℃


4.2.1.1.2 Water cooled Mid Temp 3 compressor racks

Model BBS3-
30MB 45MB 60MB 75MB 90MB 105MB 120MB 150MB
Temperature( ℃) -5℃~5℃
Refrigerant R22
Power supply 380V/50HZ
C omp. Type Semi-hermetic
Comp. Model 4VES-10 4PES-15 4NES-20 4HE-25 4GE -30 6HE-35 6GE -40 6FE-50
Qty 3 3 3 3 3 3 3 3
Condenser Type Shell & Tube
Cooling Water (m3/h) 20 26 31 42 50 57 71 86
Connector Size 2-1/2″ 2-1/2″ 3″ 3″ 3″ 4″ 5″ 5″
Cap. & Watt Te
-5℃
Cap (W) 66900 92700 109200 145200 168300 218100 250200 301200
Input (KW) 20.43 28.47 33.36 44.67 51.42 67.2 77.1 93.9
Te
-10℃
Cap (W) 53790 74400 87900 117300 136200 175800 201900 243300
Input (KW) 18.99 26.37 31.02 41.64 48.03 62.7 72.0 87.6
Te
-15℃
Cap (W) 42540 58620 69600 93300 108600 139800 160500 193800
Input (KW) 17.34 24.0 28.35 38.19 44.13 57.36 66.0 80.7
Conne
ctor
Liquid outlet Connect(mm) φ54 φ66 φ66 φ76 φ76 φ108 φ108 φ108
Gas Connect (mm) φ22 φ28 φ28 φ35 φ35 φ42 φ42 φ42
Overall Size L(mm) 2950 2950 2950 2950 2950 2950 2950 2950
W(mm) 1250 1250 1250 1250 1250 1250 1250 1250
H(mm) 1850 1850 1850 1850 1850 1850 1850 1850

Above cooling capacity and input power under condition of condensing Temp. 40 ℃

 

4.2.1.1.3Water coo led Mid Temp 4 compressor racks

Model BBS4-
40MB 60MB 80MB 100MB 120MB 140MB 160MB 200MB
Temperature( ℃) -5℃~5℃
Refrigerant R22
Power supply 380V/50HZ
Comp. Type Semi-hermetic
Comp. Model 4VES-10 4PES-15 4NES-20 4HE-25 4GE -30 6HE-35 6GE -40 6FE-50
Qty 4 4 4 4 4 4 4 4
Condenser Type Shell & Tube
Cooling Water
(m3/h)
26 35 41 55 65 76 95 115
Connector Size 2-1/2″ 3″ 3″ 4″ 4″ 5″ 5″ 5″
Cap. & Watt Te
-5℃
Cap (W) 89200 123600 145600 193600 224400 290800 333600 401600
Input (KW) 27.24 37.96 44.48 59.56 68.56 89.6 102.8 125.2
Te
-10℃
Cap (W) 71720 99200 117200 156400 181600 234400 269200 324400
Input (KW) 25.32 35.16 41.36 55.52 64.04 83.6 96.0 116.8
Te
-15℃
Cap (W) 56720 78160 92800 124400 144800 186400 214000 258400
Input (KW) 23.12 32.0 37.8 50.92 58.84 76.48 88.0 107.6
Conne Liquid outlet Connect(mm) φ54 Φ67 φ76 φ76 φ108 φ108 φ108 φ133
Gas Connect (mm) φ28 φ28 φ35 φ35 φ42 φ42 φ42 φ42
Overall Size L(mm) 3600 3600 3600 3600 3600 3600 3600 3600
W(mm) 1250 1250 1250 1250 1250 1250 1250 1250
H(mm) 1850 1850 1850 1850 1850 1850 1850 1850

Above cooling capacity and input power under condition of condensing Temp. 40 ℃


4.2.1.2 Refrigerant R404A/R507A
4.2.1.2.1 Water cooled Med. Temp 2 compressor rack

Model BBS2-
18MBY 24MBY 28MBY 36MBY 46MBY 56MBY 68MBY 88MBY
Temperature( ℃) -5℃~5℃
Refrigerant R404A/R507A
Power supply 380V/50HZ
Comp. Type Semi-hermetic
Comp. Model 4TES-9Y 4PES-12Y 4NES-14Y 4HE-18Y 4GE -23Y 6HE-28Y 6GE -34Y 6FE-44Y
Qty 2 2 2 2 2 2 2 2
Condenser Type Shell & Tube
Cooling Water
(m3/h)
16.5 19 22.5 30 35 41 51 62
Connector Size 2-1/2″ 2-1/2″ 2-1/2″ 2-1/2″ 3″ 3″ 3″ 4″
Cap. & Watt Te
-5℃
Cap (W) 53800 61800 73400 97800 113000 143600 166400 200000
Input (KW) 19.2 21.44 25.82 34.72 41.4 51 61.4 73.6
Te
-10℃
Cap (W) 43000 49000 58400 79000 91400 116000 135000 162200
Input (KW) 17.66 19.7 23.86 32.16 38.26 47.2 57.0 68.6
Te
-15℃
Cap (W) 33780 38320 46000 62800 73000 92400 108400 130000
Input (KW) 15.98 17.76 21.68 29.38 34.88 43.2 52.2 63.2
Conn ecto
r
Liquid outlet Connect(mm) φ42 φ54 φ54 φ66 φ66 φ76 φ76 φ76
Gas Connect (mm) φ22 φ22 φ28 φ28 φ28 φ35 φ35 φ35
Overall Size L(mm) 2300 2300 2300 2300 2300 2300 2300 2300
W(mm) 1250 1250 1250 1250 1250 1250 1250 1250
H(mm) 1850 1850 1850 1850 1850 1850 1850 1850

Above cooling capacity and input power under condition of condensing Temp. 40 ℃

 

4.2.1.2.2 Water cooled Med. Temp 3 compressor rack

Model BBS3-
27MBY 36MBY 42MBY 54MBY 69MBY 84MBY 102MBY 132MBY
Temperature( ℃) -5℃~5℃
Refrigerant R404A/R507 A
Power supply 380V/50HZ
Comp. Type Semi-hermetic
Comp. Model 4TES-9Y 4PES-12Y 4NES-14Y 4HE-18Y 4GE -23Y 6HE-28Y 6GE -34Y 6FE-44Y
Qty 3 3 3 3 3 3 3 3
Condenser Type Shell & Tube
Cooling Water
(m3/h)
24.5 28 34 45 52 62 77 92
Connector Size 2-1/2″ 2-1/2″ 3″ 3″ 3″ 4″ 5″ 5″
Cap. & Watt Te
-5℃
Cap (W) 80700 92700 110100 146700 169500 215400 249600 300000
Input (KW) 28.8 32.16 38.73 52.08 62.1 76.5 92.1 110.4
Te
-10℃
Cap (W) 64500 73500 87600 118500 137100 174000 202500 243300
Input (KW) 26.49 29.55 35.79 48.24 57.39 70.8 85.5 102.9
Te
-15℃
Cap (W) 50670 57480 69000 94200 109500 138600 162600 195000
Input (KW) 23.97 26.64 32.52 44.07 52.32 64.8 78.3 94.8
Connector Liquid outlet Connect(mm) φ54 φ66 φ66 φ76 φ76 φ108 φ108 φ108
Gas Connec t (mm) φ22 φ28 φ28 φ35 φ35 φ42 φ42 φ42
Overall Size L(mm) 2950 2950 2950 2950 2950 2950 2950 2950
W(mm) 1250 1250 1250 1250 1250 1250 1250 1250
H(mm) 1850 1850 1850 1850 1850 1850 1850 1850

Above cooling capacity and input power under condition of co ndensing Temp. 40 ℃


4.2.1.2.3 Water cooled Med. Temp 4 compressor rack

Model BBS4-
36MBY 48MBY 56MBY 72MBY 92MBY 112MBY 136MBY 176MBY
Temperature( ℃) -5℃~5℃
Refrigerant R404A/R507A
Power supply 380V/50HZ
Comp. Type Semi-hermetic
Comp. Model 4TES-9Y 4PES-12Y 4NES-14Y 4HE-18Y 4GE -23Y 6HE-28Y 6GE -34Y 6FE-44Y
Qty 4 4 4 4 4 4 4 4
Condenser Type Shell & Tube
Cooling Water
(m3/h)
33 38 45 60 70 82 102 123
Connector Size 2-1/2″ 3″ 3″ 4″ 4″ 5″ 5″ 5″
Cap. & Watt Te
-5℃
Cap (W) 107600 123600 146800 195600 226000 287200 332800 400000
Input (KW) 38.4 42.88 51.64 69.44 82.8 102 122.8 147.2
Te
-10℃
Cap (W) 86000 98000 116800 158000 182800 232000 270000 324400
Input (KW) 35.32 39.4 47.72 64.32 76.52 94.4 114.0 137.2
Te
-15℃
Cap (W) 67560 76640 92000 125600 146000 184800 216800 260000
Input (KW) 31.96 35.52 43.36 58.76 69.76 86.4 104.4 126.4
Connector Liquid outlet Connect(mm) φ54 Φ67 φ76 φ76 φ108 φ108 φ108 φ133
Gas Connect
(mm)
φ28 φ28 φ35 φ35 φ42 φ42 φ42 φ42
Overall Size L(mm) 3600 3600 3600 3600 3600 3600 3600 3600
W(mm) 1250 1250 1250 1250 1250 1250 1250 1250
H(mm) 1850 1850 1850 1850 1850 1850 1850 1850

Above cooling capacity and input power under condition of condensing Temp. 40 ℃

 

4.2.2 Water cooled Low Temp (Te-20~-40℃.Refrigerant R404A/R507A )
4.2.2.1 Water cooled Low Temp 2 compressor rack

Model BBS2
18LBY 28LBY 36LBY 46LBY 56LBY 68LBY 88LBY
Temperature( ℃) -15℃~-30℃
Refrigerant R404A/R507A
Power supply 380V/50HZ
Comp. Type Semi-hermetic
Comp. Model 4TES-9Y 4NES-14Y 4HE-18Y 4GE -23Y 6HE-28Y 6GE -34Y 6FE-44Y
Qty 2 2 2 2 2 2 2
Condenser Liquid outlet Shell & Tube
Gas Connect (mm) 7.5 10 14 16 20 25 29
Liquid outlet Connect(mm) 2-1/2″ 2-1/2″ 2-1/2″ 2-1/2″ 2-1/2″ 2-1/2″ 3″
Cap. & Watt Te
-25℃
Cap (W) 19880 27000 38100 44800 56000 67200 80200
Input (KW) 12.4 16.9 23.4 27.8 34.5 42.2 51.0
Te
-30℃
Cap (W) 14740 20000 28760 34000 42400 51600 61000
Input (KW) 10.6 14.5 20.4 24.2 29.94 36.9 44.8
Te
-35℃
Cap (W) 10600 14400 21100 25240 31140 38580 45400
Input (KW) 8.9 12.0 17.4 20.7 25.42 31.8 38.5
Te
-40℃
Cap (W) 7320 9960 14880 18100 22000 28000 32380
Input (KW) 7.3 9.8 14.6 17.4 21.02 26.9 32.4
Conne
ctor
Liquid outlet Connect(mm) φ54 φ54 φ54 φ66 φ66 φ76 φ76
Gas Connect (mm) φ22 φ22 φ22 φ28 φ28 φ28 φ28
Overall Size L(mm) 2300 2300 2300 2300 2300 2300 2300
W(mm) 1250 1250 1250 1250 1250 1250 1250
H(mm) 1850 1850 1850 1850 1850 1850 1850

Above cooling capacity and input power under condition of condensing Temp. 40 ℃


4.2.2.2 Water cooled Low Te mp 3 compressor rack

Model BBS3-
27LB 42LB 54LB 69LB 84LB 102LB 132LB
Temperature( ℃) -15℃~-30℃
Refrigerant R404A/R507A
Power supply 380V/50HZ
Comp. Type Semi-hermetic
Comp. Model 4TES-9Y 4NES-14Y 4HE-18Y 4GE -23Y 6HE-28Y 6GE -34Y 6FE-44Y
Qty 3 3 3 3 3 3 3
Condenser Liquid outlet Connect(mm) Shell & Tube
Gas Connect (mm) 11 15 21 24 29 36 43.5
Liquid outlet Connect(mm) 2-1/2″ 2-1/2″ 2-1/2″ 2-1/2″ 3″ 3″ 3″
Cap. & Watt Te
-25℃
Cap (W) 29800 40560 57150 67200 84000 100800 120300
Input (KW) 18.6 25.4 35.2 41.6 51.75 63.3 76.5
Te
-30℃
Cap (W) 22100 30000 43140 51000 63600 77400 91500
Input (KW) 15.9 21.7 30.6 36.3 44.91 55.4 67.2
Te
-35℃
Cap (W) 15900 21660 31650 37860 46710 57870 68100
Input (KW) 13.3 18.1 26.1 31.0 38.13 47.7 57.8
Te
-40℃
Cap (W) 11000 14940 22300 27150 33000 41970 48570
Input (KW) 10.89 14.6 21.8 26.0 31.53 40.4 48.6
Conn
ector
Liquid outlet Connect(mm) φ54 φ54 φ66 φ76 φ76 φ108 φ108
Gas Connect (mm) φ22 φ22 φ28 φ28 φ28 φ35 φ35
Overall Size L(mm) 2950 2950 2950 2950 2950 2950 2950
W(mm) 1250 1250 1250 1250 1250 1250 1250
H(mm) 1850 1850 1850 1850 1850 1850 1850

Above cooling capacity and input power under condition of condensing Temp. 40 ℃

 

4.2.2.3 Water cooled Low Temp 4 compressor rack

Model BBS4-
36LBY 56LBY 72LBY 92LBY 112LBY 136LBY 176LBY
Temperature( ℃) -15℃~-30℃
Refrigerant R404A/R507A
Power supply 380V/50HZ
Comp. Type Semi-hermetic
Comp. Model 4TES-9Y 4NES-14Y 4HE-18Y 4GE -23Y 6HE-28Y 6GE -34Y 6FE-44Y
Qty 4 4 4 4 4 4 4
Condenser Liquid outlet Connect(mm) Shell & Tube
Gas Connect (mm) 15 20 28 32 40 48 58
Liquid outlet Connect(mm) 2-1/2″ 2-1/2″ 3″ 3″ 3″ 4″ 4″
Cap. & Watt Te
-25℃
Cap (W) 39760 54000 76200 89600 112000 134400 160400
Input (KW) 24.8 33.8 46.9 55.5 69.0 84.4 102.0
Te
-30℃
Cap (W) 29480 40000 57520 68000 84800 103200 122000
Input (KW) 21.2 28.9 40.8 48.4 59.88 73.8 89.6
Te
-35℃
Cap (W) 21200 28880 42200 50480 62280 77160 90800
Input (KW) 17.8 24.1 34.8 41.4 50.84 63.6 77.0
Te
-40℃
Cap (W) 14640 19920 29760 36200 44000 55960 64760
Input (KW) 14.5 19.5 29.1 34.7 42.04 53.8 64.8
Connector Liquid outlet Connect(mm) φ66 φ66 φ76 φ76 φ108 φ108 φ108
Gas Connect (mm) φ22 φ28 φ28 φ28 φ35 φ35 φ35
Overall Size L(mm) 3600 3600 3600 3600 3600 3600 3600
W(mm) 1250 1250 1250 1250 1250 1250 1250
H(mm) 1850 1850 1850 1850 1850 1850 1850

 

Compact Semi Hermetic Parallel Rack Refrigeration BBS Series 1Compact Semi Hermetic Parallel Rack Refrigeration BBS Series 2Compact Semi Hermetic Parallel Rack Refrigeration BBS Series 3Compact Semi Hermetic Parallel Rack Refrigeration BBS Series 4Compact Semi Hermetic Parallel Rack Refrigeration BBS Series 5Compact Semi Hermetic Parallel Rack Refrigeration BBS Series 6