100RB 200RA 240RA two way solenoid valve Normally Closed Solenoid Valve Refrigerant solenoid valve

Place of Origin Mexico
Brand Name Emerson
Model Number 240RA-12T7T
Minimum Order Quantity 10
Price 150
Packaging Details Carton Box
Delivery Time 3-8days
Payment Terms L/C, T/T, Western Union
Supply Ability 500 units per month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Model Number 240RA-12T7T Refrigerant R22/R404A/R507
Product Name Solenoid Valve Description Refrigerant Solenoid Valve
Weight (KG 2
High Light

KP61 060L1100 Thermostat Temperature Controller

,

Thermostat Control Cold Storage Parts

,

Cold Storage Thermostat Temperature Controller

Leave a Message
Product Description

100RB 200RA 240RA two way solenoid valve Normally Closed Solenoid Valve Refrigerant solenoid valve

 

The 100RB is a direct-acting, 2-way, normally closed valve. 100 RB
valves are used for liquid or discharge gas refrigerant service.
Features
• One coil fits all valve sizes
• Extended ends for easy installation (standard)
• Long-life molded coils
• PTFE O-ring for superior external sealing
Options
• SAE or ODF connection sizes in 1/4” and 3/8”, 1/4” NPTF
 
Specifications
• Maximum fluid temperature: 250°F
• Maximum working pressure: 500 psig
• MOPD: 300 psig
• UL/CUL file number: MP 604
NOTE: Mounting enclosing tube more than 90° off vertical
up position is not recommended.
 

Nomenclature example: 100RB 2F2 VLC

100R B 2 F 2 VLC
Valve Series Design Series

Port Size

(in 1/16”)

Connection Type

F= SAE

S=ODF

P=NPTF

Connection Size

(in 1/8”)

Coil*

 

NOTE: Valves are shipped without the solenoid coils (VLC = Valve Less Coil). See coil assemblies for availability.
 
100RB 2S3  two way solenoid valve Normally Closed Solenoid Valve Refrigerant solenoid valve
100RB 2S3  two way solenoid valve Normally Closed Solenoid Valve Refrigerant solenoid valve
100RB 2S3  two way solenoid valve Normally Closed Solenoid Valve Refrigerant solenoid valve
100RB 2S3  two way solenoid valve Normally Closed Solenoid Valve Refrigerant solenoid valve
100RB 200RA 240RA two way solenoid valve Normally Closed Solenoid Valve Refrigerant solenoid valve 4
200RB Solenoid Valves & Coils
The 200RB is a pilot-operated, 2-way, normally closed valve. 200RB valves are used for liquid, discharge, or suction gas refrigerant service.
Features
• One coil fits all valve sizes
• Extended ends for easy installation (standard)
• Long-life molded coils
• PTFE O-ring for superior external sealing
Options
• Available in 7 orifice sizes
• Manual stem or mounting stud
• Bi-Flow operation-conversion either factory assembled or with kit (except 200RB 7 & 9 )
Nomenclature example: 200RB 4T3M VLC
Specifications
• Maximum fluid temperature: 250°F
• Maximum working pressure: 500 psig
• Minimum operating pressure drop: 2 psi
• MOPD: 300 psig
• UL/CUL file number: MP604
NOTE: Mounting enclosing tube more than 90o off vertical up position is not recommended.
200R B 4 T 3 M VLC    
Valve Series Design Port Size Connection Type Connection Size   Coil*    
  Series (in 1/16”) F = SAE (In 1/8”) M = manual stem      
      S = ODF   T = mounting stud      
      P = NPTF   (optional)      
      T = Copper Extended Ends          
*NOTE: Valves are shipped without the solenoid coils (VLC = Valve Less Coil). See coil assemblies for availibility.
Ordering Information and Nominal* Liquid Capacity Table – Tons (kW)
PCN Description Connection Size R-12 R-134a R-22 R-407C R-404A/R-507 R-502  
Standard
Valve
Mounting
Stud1
Manual
Stem2
 
053104 - - N/A 200RB 2 F 2 1/4 SAE 2.3 (8.1) 2.7 (9.5) 3.6 (12.7) 3.4 (12.0) 1.9 (6.7) 1.9 (6.7)  
062611 - - N/A 200RB 2 F 3 3/8 SAE  
053105 053236 N/A 200RB 2 T 2 1/4 ODF  
053106 054170 N/A 200RB 2 T 3 3/8 ODF  
052725 - - - - 200RB 3 F 2 1/4 SAE 3.0 (10.6) 3.6 (12.7) 4.8 (16.9) 4.5 (15.8) 2.5 (8.8) 2.6 (9.1)  
052726 056438 - - 200RB 3 F 3 3/8 SAE  
052727 055855 - - 200RB 3 F 4 1/2 SAE  
049608 - - - - 200RB 3 T 2 1/4 ODF  
049609 049585 065620 200RB 3 T 3 3/8 ODF  
049692 - - 065621 200RB 3 T 4 1/2 ODF  
047506 047508 047507 200RB 4 F 3 3/8 SAE 5.0 (17.6) 6.0 (21.1) 8.0 (28.1) 7.5 (26.4) 4.2 (14.8) 4.2 (14.8)  
059728 047510 047509 200RB 4 P 3 3/8 NPTF  
047511 047513 047512 200RB 4 S 3 3/8 ODF X 1/2 ODM  
047516 047515 047514 200RB 4 S 4 1/2 ODF X 5/8 ODM  
047517 049162 049186 200RB 4 T 3 3/8 ODF  
047518 049163 049187 200RB 4 T 4 1/2 ODF  
058950 058045 056518 200RB 4 T 5 5/8 ODF  
047519 047521 047520 200RB 5 F 4 1/2 SAE 5.2 (18.3) 6.2 (21.8) 8.2 (28.8) 7.7 (27.1) 4.3 (15.1) 4.5 (15.8)  
059729 047523 047522 200RB 5 F 5 5/8 SAE  
047524 047526 047525 200RB 5 S 4 1/2 ODF X 5/8 ODM  
049201 047528 047527 200RB 5 S 5 5/8 ODF  
061227 054323 - - 200RB 5 T 3 3/8 ODF  
057206 049164 049188 200RB 5 T 4 1/2 ODF  
059730 049165 049189 200RB 5 T 5 5/8 ODF  
059731 047531 047530 200RB 6 F 4 1/2 SAE 6.0 (21.1) 7.2 (25.3) 9.5 (33.4) 8.9 (31.3) 5.0 (17.6) 5.1 (17.9)  
059732 047534 047533 200RB 6 F 5 5/8 SAE  
059733 047536 047535 200RB 6 P 3 3/8 NPTF  
047537 047539 047538 200RB 6 S 4 1/2 ODF X 5/8 ODM  
047540 047542 047541 200RB 6 S 5 5/8 ODF  
047544 047546 047545 200RB 6 T 4 1/2 ODF  
056766 047548 047547 200RB 6 T 5 5/8 ODF  
064037 - - - - 200RB 7 S 5 5/8 ODF X 7/8 ODM 10.8 (38.0) 12.7 (44.7) 17.0 (59.8) 16.2 (57.0) 9.1 (32.0) 9.2 (32.4)  
064062 - - - - 200RB 7 T 4 1/2 ODF  
064063 064562 064267 200RB 7 T 5 5/8 ODF  
064282 064284 064283 200RB 7 T 7 7/8 ODF  
064762 064764 064763 200RB 9 T 5 5/8 ODF 19.6 (68.9) 23.6 (83.0) 30.5 (107.3) 29.0 (102.0) 16.4 (57.7) 16.2 (57.0)  
064645 064766 064765 200RB 9 T 7 7/8 ODF  
064767 064769 064768 200RB 9 T 9 1 1/8 ODF  
1 Add “T” to the end of description for Mounting Stud
2 Add “M” to the end of the description for Manual Stem
Capacities based on 100°F liquid and 40°F saturated evaporator per ARI standard 760-87. All ratings are based on largest connection size.
*See Extended Capacity Tables for ratings at a wide range of conditions.

The 240RA is a 2-way, normally closed diaphragm valve. 240RA valves are used for liquid, suction, and hot gas service.

100RB 200RA 240RA two way solenoid valve Normally Closed Solenoid Valve Refrigerant solenoid valve 5

Features

One coil fits all valve sizes

Can be brazed into the line without disassembly

PTFE diaphragm for high temperature applications

Extended ends for easy installation (standard)

Long-life molded coils

Mounting stud models can be field converted to

manual stem

 

Options

Manual stem or mounting stud

 

Nomenclature example: 240RA 8T5M VLC

Specifications

Maximum fluid temperature: 250°F

Maximum working pressure: 500 psig

MOPD: 300 psig

UL/CUL file number: MP604

 

NOTE: Mounting enclosing tube more than 90o off vertical up position is not recommended.

 
240R A** 8 T 5 M VLC
Valve Series Design Series

Port Size

(in 1/16”)

Connection Type

T = copper entended ends

Connection Size

(in 1/8”)

M = manual stem T = mounting stud (optional) Coil*

* NOTE: Valves are shipped without the solenoid coils (VLC = Valve Less Coil). See coil assemblies for availability.

**NOTE: Letter “H” is no longer used since all 240RA valves now contain the high temperature diaphragm for hot gas.

 

Ordering Information and Nominal* Liquid Capacity Table – Tons (kW)

PCN Description Connection Size R-12 R-134a R-22 R-407C R-404A/R-507 R-502

Standard

Valve

Mounting

Stud1

Manual

Stem2

060374 040846 040845 240RA 8 T 5 5/8 ODF 12.2 (43.4) 14.8 (52.5) 15.6 (55.2) 14.8 (52.4) 8.4 (29.5) 10.1 (35.0)
060375 044860 045753 240RA 8 T 7 7/8 ODF
060376 040848 040847 240RA 9 T 5 5/8 ODF 18.2 (64.6) 22.0 (78.0) 23.3 (82.5) 22.1 (78.2) 15.3 (54.2) 15.1 (53.5)
060377 043205 043204 240RA 9 T 7 7/8 ODF 24.0 (85.0) 28.9 (102.3) 30.5 (108.0) 29.0 (103.0) 21.0 (71.1) 19.8 (70.1)
060378 044861 045752 240RA 9 T 9 1 1/8 ODF
060379 040850 040849 240RA 12 T 7 7/8 ODF 27.6 (97.6) 33.2 (117.5) 34.9 (124.0) 33.2 (118.0) 23.0 (81.4) 22.7 (80.4)
060380 043959 045549 240RA 12 T 9 1 1/8 ODF
060381 042549 042548 240RA 16 T 9 1 1/8 ODF 37.3 (132.0) 55.1 (195.1) 58.0 (205.0) 55.2 (195.0) 38.3 (135.0) 37.3 (133.0)
060382 044428 044788 240RA 16 T 11 1 3/8 ODF
060383 047761 046636 240RA 20 T 11 1 3/8 ODF

 

58.8 (208.0)

 

86.8 (307.4)

 

95.4 (338.0)

 

90.8 (321.0)

 

65.7 (230.0)

 

62.0 (219.0)

060384 047747 046637 240RA 20 T 13 1 5/8 ODF
060385 054297 046638 240RA 20 T 17 2 1/8 ODF

 

 

1 Add “T” to the end of description for Mounting Stud

2 Add “M” to the end of the description for Manual Stem

Capacities based on 100°F liquid and 40°F saturated evaporator per ARI standard 760-87.

*See Extended Capacity Tables for ratings at a wide range of condition

40HP Carrier Semi Hermetic CARLYLE COMPRESSOR FOR HVAC SYSTEM 06EA299600 Central air conditioning Chiller 0Carrier Carlyle Cold Room Compressor 18-00055-20rm2 Ac Power Cfm Designation Oil Less  Lubrication 1

 

 

Carrier Carlyle Cold Room Compressor 18-00055-20rm2 Ac Power Cfm Designation Oil Less  Lubrication 2

Carrier Carlyle Cold Room Compressor 18-00055-20rm2 Ac Power Cfm Designation Oil Less  Lubrication 3

Carrier Carlyle Cold Room Compressor 18-00055-20rm2 Ac Power Cfm Designation Oil Less  Lubrication 4

Carrier Carlyle Cold Room Compressor 18-00055-20rm2 Ac Power Cfm Designation Oil Less  Lubrication 5

Carrier Carlyle Cold Room Compressor 18-00055-20rm2 Ac Power Cfm Designation Oil Less  Lubrication 6

Carrier Carlyle Cold Room Compressor 18-00055-20rm2 Ac Power Cfm Designation Oil Less  Lubrication 7

 

Back to homepage